Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Sulphur Di-oxide Monitoring Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Sulphur Di-oxide Monitoring Questions & Answers

Sulphur Di-oxide Monitoring Questions & Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
7 Min Read
SHARE

Sulphur Di-oxide Monitoring Questions & Answers

1. In West-Gaeke colourimetric procedure, the intensity of the red purple colour is measured photometically and it is proportional to the concentration of sulphur di-oxide. What is the red purple coloured compound?

a) Sodium tetra chloromercurate
b) Dicholorosulphitomercurate complex
c) Ammonia molybdate
d) Paraosaniline sulphonic acid

Answer: d

Explanation: Sulphur di-oxide reacts with Sodium tetra chloromercurate to form Dicholorosulphitomercurate complex which then reacts with formaldehyde and pararosaniline to form Parapsaniline sulphonic acid which is red purple coloured.

2. The conductivitimetry method, involves bubbling sulphur di-oxide through a solution containing sulphuric acid and which of the following?

a) Water
b) Hydrogen peroxide
c) Iodine
d) Formaldehyde

Answer: b

Explanation: The conductivitimetry method, involves bubbling sulphur di-oxide through a solution containing sulphuric acid and hydrogen peroxide. It results in the formation of sulphuric acid.

3. Which of the following are not the characteristics of conductivitimetry method used to measure sulphur di-oxide?

a) Fast response
b) High sensitivity
c) Free from interference by other gases
d) Good accuracy

Answer: c

Explanation: Conductivitimetry instruments are affected by other gases and they cause interference. The other gases may produce or remove ions in the solution.

4. Which of the following are not the characteristics of colorimetry method used to monitor sulphur di-oxide?

a) It is simple
b) It has high sensitivity
c) It has good specificity
d) It is affected by interference from H2SO4, SO3, NH3, etc

Answer: d

Explanation: Colorimetry method is free from by the interference due to other gases such as It is affected by interference from H2SO4, SO3, NH3, etc. Colour intensity is sensitive to temperature.

5. Which of the following is not true about using gas chromatography for measuring pollutants in air?

a) Pollutants react rapidly in the column
b) Pollutants may not be detected by the detectors
c) Special column and support materials are required
d) Pollutants may elude rapidly from the column

Answer: d

Explanation: Most of the pollutants are extreme reactive materials. Hence, they may not pass through the column and appear at the detector.

6. The ability of sulphur dioxide to reduce iodine is used in which of the following methods?

a) Colorimetry
b) Conductivitimetry
c) Coulometry
d) Gas chromatography

Answer: c

Explanation: The ability of sulphur dioxide to reduce iodine is used in Coulometry method to measure sulphur di-oxide. The mass of I2 reacted per unit time will indicate the amount of sulphur di-oxide.

7. Which of the following materials are used as electrodes in coulometric method for the measurement of sulphur di-oxide?

a) Gold
b) Silver
c) Platinum
d) Nickel

Answer: c

Explanation: In Coulometric arrangement, the electrodes are made of platinum. These act as the anode and the cathode.

8. Which of the following is the detection limit of coulometric method used for measurement of sulphur di-oxide?

a) 0.1 ppm
b) 1 ppm
c) 2 ppm
d) 0.01 ppm

Answer: d

Explanation: The detection limit of coulometric method is 0.01 ppm. The shift in anode cathode potential is detected by a third electrode.

9. Sensitivity to total sulphur by Flame-photometric detector is which of the following levels?

a) 0.1 ppm
b) 1 ppm
c) 2 ppm
d) 0.01 ppm

Answer: d

Explanation: Sensitivity to total sulphur by Flame-photometric detector is 0.01 ppm. Here, sample air is introduced into a hydrogen-rich air flame.

10. Which of the following methods are not used for the measurement of sulphur di-oxide?

a) Colorimetric method
b) Correlation spectroscopy
c) Paramagnetic analyzers
d) Flame-photometry

Answer: c

Explanation: Sulphur di-oxide cannot be analysed using paramagnetic analyzer. This is because sulphur di-oxide does not have paramagnetic property.

11. Which of the following is the wavelength of the radiation generated when an air stream containing sulphur di-oxide is burned in a hydrogen-rich flame?

a) 243 nm
b) 394 nm
c) 467 nm
d) 516 nm

Answer: b

Explanation: The wavelength of the radiation generated when an air stream containing sulphur di-oxide is burned in a hydrogen-rich flame is 394 mm. A narrow band interference filter is used to shield radiations with all other wavelengths.

12. Given below, is the diagram of Ultraviolet Fluorescence method. Identify the unmarked component.

a) Filter
b) Electronic circuit
c) Supply
d) Fluorescence chamber

Answer: d

Explanation: The unmarked block is Fluorescence chamber. Here, fluorescence of SO2 is emitted.

13. In conductivitimetric method, the concentration of sulphur di-oxide is proportional to which of the following parameters of the saw-tooth waveform?

a) Average voltage
b) Peak voltage
c) Slope
d) RMS voltage

Answer: c

Explanation: In conductivitimetric method, the concentration of sulphur di-oxide is proportional to slope of the saw-tooth waveform. Current is recorded every 15 minutes.

14. In conductivitimetric method, to measure the conductivity of the cell, 5V ___________ is applied across the electrodes.

a) DC
b) AC
c) Pulsating DC
d) DC or AC

Answer: b

Explanation: In conductivitimetric method, to measure the conductivity of the cell, 5V alternating current is applied across the electrodes. This is because alternating current avoids polarisation.

15. The response of coulometric method is instantaneous.

a) True
b) False

Answer: b

Explanation: The response of coulometric method is not instantaneous. It may take about 4 minutes for 90 percent of the signal to appear for any concentration of SO2.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Thermal Conductivity Analyzers Questions & Answers
Level and Density Measurement Objective Questions
Design Considerations for Higher Order Systems
Top 10 Industrial safety Objective Questions
Controller Components – Part 1 Objective Questions
Online Analyzers Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Root Locus in Control Systems
Frequency Response MCQ
Biosensors Questions & Answers
Feedback and Non-feedback Systems Objective Questions
Measurement and Instrumentation Objective Questions – Part 5
Level Measurement Multiple Choice Questions

Keep Learning

State Variable Analysis and Design

Pole Placement by State Feedback

Infrared Spectrometers Questions & Answers

Infrared Spectrometers Questions & Answers

Control Systems Stability and Algebraic Criteria

Necessary Conditions for Stability & Non-Linear Systems

Flame Emission Photometers Questions & Answers

Flame Emission Photometers Questions & Answers

Process Control Questions & Answers

Process Control Questions & Answers

Electron Spin Resonance Questions & Answers

Basic ESR Spectrometer

Pollution Monitoring Instruments Questions and Answers

Hydrocarbons Questions & Answers

Transmission and Distribution Interview Questions

Measurement and Instrumentation Objective Questions – Part 3

More Articles

UL 489 Circuit Breaker

Difference Between UL489 and UL1077

FF JB Termination

Foundation Fieldbus Installation and Best Practices

Level Transmitter with Zero Suppression

DP Level Transmitters Compensation Techniques

Relay-Operation

Relay Working Animation

Emergency Shutdown System Philosophy

Shutdown Philosophy

Tap Changing Switch Animation

Types of Power Electronic Devices

Power Electronic Devices Specification and Classification

Basic Power Electronics Interview Questions

Basic Power Electronics Interview Questions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?