Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Detection System of Gas Chromatography Questions and Answers

Detection System of Gas Chromatography Questions and Answers

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
7 Min Read
SHARE

Detection System of Gas Chromatography Questions and Answers

1. Which of the following is not an ideal characteristic of a detector used in gas chromatography?

a) Linear response to the solutes
b) Short response time
c) High reliability
d) Sensitive to the changes in the flow rate of carrier gas

Answer: d

Explanation: The detector used in gas chromatography must be insensitive to the changes in flow rate of carrier gas. There are many detectors used in gas chromatography.

2. Which of the following is not a type of detector used in gas chromatography?

a) Argon ionisation detector
b) Thermal conductivity detector
c) UV visible spectrometric detector
d) Electron capture detector

Answer: c

Explanation: UV visible spectrometric detector is not used in gas chromatography. It is used in liquid chromatography.

3. Which of the following detectors have high sensitivity to all organic compounds?

a) Sulphur chemiluminescense detector
b) Thermionic emission detector
c) Flame ionization detector
d) Argon ionisation detector

Answer: c

Explanation: Flame ionization detector has high sensitivity to all organic compounds. It is the commonly used detector for gas chromatography.

4. Which of the following is not the advantage of thermal conductivity detector used in gas chromatography?

a) Simple in construction
b) High sensitivity
c) Large linear dynamic range
d) Non-destructive character

Answer: b

Explanation: Thermal conductivity detector has relatively low density when compared to other detectors used in gas chromatography. It is based on the principle that all gases conduct heat in varying degrees.

5. Which of the following detectors is widely used to detect environmental samples like chlorinated pesticides and polychlorinated biphenyls?

a) Flame ionization detector
b) Thermal conductivity detector
c) Argon ionisation detector
d) Electron capture detector

Answer: d

Explanation: Electron capture detector is used to detect environmental samples like polychlorinated biphenyls and chlorinated pesticides. It is highly sensitive to molecules containing functional groups such as halogen and phosphorous.

6. In which of the following detector is the eluent mixed with hydrogen and burned and then mixed with ozone and its intensity is measured?

a) Sulphur chemiluminescense detector
b) Thermal conductivity detector
c) Flame ionization detector
d) Electron capture detector

Answer: a

Explanation: In Sulphur chemiluminescense detector, the eluent is mixed with hydrogen and burned and then mixed with ozone and its intensity is measured. The resultant is a measure of sulphur compounds present.

7. Filter photometer detector is primarily responsive to which of the following compounds/elements?

a) Volatile sulphur or phosphorous compounds
b) Nitrogen
c) Halogen
d) Potassium

Answer: a

Explanation: Flame photometric detector is primarily responsive to volatile sulphur or phosphorous compounds. It is also responsive to tin and nitrogen.

8. Which of the following detector uses ultraviolet radiation from lamps to produce ionisation of solute molecules?

a) Sulphur chemiluminescense detector
b) Thermal conductivity detector
c) Photo ionization detector
d) Electron capture detector

Answer: c

Explanation: Photo ionization detector uses ultraviolet radiation from lamps to produce ionisation of solute molecules. The current produced is measured and recorded.

9. Flame ionisation detector is also known as Katharometer.

a) True
b) False

Answer: b

Explanation: Thermal conductivity detector is known as Katharometer. It uses heated filament as sensing element and it is placed in the emerging gas stream.

10. Thermionic emission detector used in gas chromatography is most sensitive to which of the following elements?

a) Nitrogen
b) Phosphorous
c) Halogen
d) Carbon

Answer: b

Explanation: Thermionic emission detector used in gas chromatography is most sensitive to phosphorous. It is 500 times more sensitive to phosphorous than Flame ionization detector.

11. Which of the following detectors has a non-volatile bead of rubidium silicate placed above the flame tip?

a) Argon ionisation detector
b) Thermionic emission detector
c) Flame ionization detector
d) Electron capture detector

Answer: b

Explanation: Thermionic emission detector has a non-volatile bead of rubidium silicate placed above the flame tip. It is maintained at about 180V with respect to the collector.

12. In which of the following detectors, the carrier gas is excited by a radioactive source and the atoms of carrier gas are excited to metastable state?

a) Argon ionisation detector
b) Thermionic emission detector
c) Flame ionization detector
d) Electron capture detector

Answer: a

Explanation: In Argon ionisation detector, the carrier gas is excited by a radioactive source and the atoms of carrier gas are excited to metastable state. It uses argon as carrier gas.

13. Which of the following is not used as a heating element in Thermal conductivity detector?

a) Platinum
b) Gold
c) Graphite
d) Tungsten wire

Answer: c

Explanation: Graphite is not used as heating element in Thermal conductivity detector. Platinum, gold and tungsten wire are used as heating elements.

14. Electron capture detector is much less susceptible to contamination when nickel is used instead of tritium.

a) True
b) False

Answer: a

Explanation: Electron capture detector is much less susceptible to contamination when nickel is used instead of tritium. The sensitivity of nickel is less than that of tritium.

15. Given below is a diagram of electron capture detector. Identify the unmarked component in the diagram.

a) Glass shield
b) Electrode
c) Quartz shield
d) Radioactive β- emitter

Answer: d

Explanation: The unmarked component is Radioactive β- emitter. Nitrogen and hydrogen are the best carrier gases for these detectors.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Infrared Gas Analyzers Questions & Answers
Amino-Acid Analyzers Questions & Answers
Ion Analyzer Questions & Answers
Hydrocarbons Questions & Answers
Measurement and Instrumentation Objective Questions – Part 1
Steady-state Errors & Error Constants
Share This Article
Facebook Copy Link Print
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Process Control Questions & Answers
Cascade Compensation in Time Domain
Nuclear Magnetic Resonance Spectrometer Questions & Answers
Performance Indices
Electrical Measurements and Instrumentation Objective Questions & Answers
Total Reflection Spectrometer Questions & Answers
Sodium Analyzer Questions & Answers
Analytical Measurement Multiple Choice Questions
Ion Selective Electrodes Questions and Answers
Feedback Control Loop Questions & Answers

Keep Learning

Stability in Frequency Domain

Mathematical Preliminaries

Analyzers Questions and Answers

Magnetic Wind Instruments Questions & Answers

Mass Spectrometer Questions and Answers

Inductively Coupled Plasma Mass Spectrometer

Electron Spin Resonance Questions & Answers

Basic ESR Spectrometer

pH Analyzers Questions and Answers

pH Measurement Questions & Answers

Instrumentation Diagrams Multiple Choice Questions

Instrumentation Diagrams Multiple Choice Questions

Mass Spectrometer Questions and Answers

Gas Chromatograph- Mass Spectrometer

Liapunov’s Stability Analysis

Liapunov’s Stability Criterion – Part I

Discover More

Phase Controlled Half Wave Rectifier RL Load

Power Electronics – Phase Controlled Half Wave Rectifier RL Load

Power Electronics Objective Questions

Single Phase Full Wave AC DC Converter MCQ

Cooling Tower Fans Frequently Failing

Cooling Tower Fans Frequently Failing

PLC Batch System for 4 Tanks Mixing using CX-Programmer

PLC Batch System for 4 Tanks Mixing using CX-Programmer

Electrical Heating Objective Questions and Answers

Electrical Heating Objective Questions and Answers

Web Tension Measurement

Web Tension Measurement and Control Technologies

Common Valve Abbreviations

Common Valve Abbreviations in US Engineering Drawings

Process Shutdown

Difference between Process shutdown and Emergency Shutdown

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?