Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Why We use Shielded Cable and Twisted Pair Cables ?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation Design > Why We use Shielded Cable and Twisted Pair Cables ?

Why We use Shielded Cable and Twisted Pair Cables ?

Last updated: July 7, 2020 5:04 pm
Editorial Staff
Instrumentation Design
No Comments
Share
3 Min Read
SHARE

Using shielded cable and/or twisted pair wire is a fairly simple and effective method of reducing measurement noise in low-level signals.

Internal wires are shielded from external electric fields in a shielded cable when the shield is tied to a low-impedance potential, such as ground. When shielding low-frequency (≤1 MHz) analog signals, it is usually best to tie the cable shield to ground at only one end of the cable. This prevents shield currents which occur due to ground differences between the ends of the cable, inducing noise on internal wires.

Higher level signals such as digital control and power connections are typically immune to noise induced by shield currents. As a result, its usually best to connect the shields to ground at both ends of the cables containing only digital control and/or power signals.

Shielded cable is relatively inexpensive and is recommended in all applications. Connect shields to ground at both ends of the cable if the cable does not contain any analog signals; connect the shield to only one end if the cable contains analog signals

Twisted pairs offer immunity to both electric and magnetic fields. Consider a differential sensor connected to a differential input with a twisted pair wire. As previously mentioned, external electrical fields exert similar influence into the close proximity wires of a twisted pair, resulting in common-mode noise if both wires have the same impedance.

External magnetic fields induce voltages in loops proportional to the area of the loop. Twisting the conductor pair between the source and load minimizes this loop area, but also helps cancel noise because induced voltages are of equal magnitude and opposite polarity in adjacent twists.

Consequently, twisted pair provides better immunity to magnetic fields than two closely spaced parallel conductors.

Twisted pair wires also reduce the emission of magnetic fields. Consider a large dc current flowing on a twisted pair between a source and load. The current flow in the two close proximity wires is equal and opposite, with the resulting magnetic fields effectively cancelling each other within a few inches of the pair.

The close proximity of twisted pair wires results in common mode noise from external electric fields and cancellation of voltages induced from magnetic fields. Differential measurements effectively reject common-mode noise. A twisted pair between a source and a load also reduces magnetic field emissions.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

General Specification of Thermowell
Control Room Design Guidelines
What are Impulse Lines? – Impulse Line Problems & Solutions
What is Inter Discipline Check (IDC)?
What is Contact bounce ?
Blast Furnace Panel Modification to Reduce Down Time by 60 to 70%
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Redundant Power Supply for Critical Field Panels
Pressure Control Valves vs Pressure Regulators
All About Variable Area Flow Meters
Guided Wave Radar Level Sensor Pressure and Temperature Effects
Immersion Heaters in Lube Oil Consoles
How to Fill up Instrument Datasheet? – Pressure Gauge Specifications & Standards
Determine the Status of Lamps and Relays in the Circuit ?
Instrumentation Books Download

Keep Learning

What to Choose RTD or Thermocouple ?

Instrumentation Earthing

Instrumentation Earthing

Orifice Beta

Why is Orifice Beta in between 0.3 to 0.7?

process conditions, Find out the Circuit Components Status

As per Process Conditions, Find out the Circuit Components Status ?

control-valve-actuators

Control Valve Selection Tips

History of 3-15 psi, 10-50 mA, and 4-20 mA signals

History of 3-15 psi, 10-50 mA, and 4-20 mA signals

Instrument Air Sizing

Instrument Air Sizing

30 Concerns for Control System Philosophy (Industrial Automation)

30 Concerns for Process Control Systems Philosophy

Learn More

PID Loop Tuning

PID Controller Loop Tuning Questions and Answers – Part 1

Thyristor Interview Questions & Answers

Thyristor Interview Questions & Answers

Programmable Logic Controller (PLC) Questions and Answers

Programmable Logic Controller (PLC) Questions and Answers – 6

Why does SMPS Need isolation - Switch Mode Power Supply

Why does SMPS Need isolation? – Switch Mode Power Supply

Coriolis Mass Flow meter as a Multi Variable Transmitter - 2

Coriolis Flowmeter Advantages and Limitations

100 Digital Electronics and Microprocessor Questions for Practice Exam

100 Digital Electronics and Microprocessor Questions for Practice Exam

Encode and Decode Instructions

How to Use Encode and Decode Instructions in PLC ?

main controller fails

How does a Redundant Controller comes in line when the Main Controller fails?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?