Shaft and Coupling Bore Tapers Repair Caused Frequent Shutdowns

often-found fret-pitted shaft and coupling bore tapers repair caused frequent and lengthy shutdowns.

Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:High Speed, Hi KW Major Rotating Machines
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of one or two decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Root Cause Analysis

RCA Queries (Q), Answers and Actions taken (A) follow:

Q: What is fretting Corrosion (FC) and Why?

A: FC is localized surface damages of tightly fitted parts. The author attributes it to the crew used coupling assembling method: Crew lap the shaft taper and coupling bore using CI lappers until the shaft and coupling tapers blue match min 80% contact. They wipe the blue, oil the parts and hand tighten the coupling nut. With a dial gauge touching the coupling face, they spanner tighten the end nut to realize the specified coupling travel aka coupling draw in compressor parlance to realize 0.5 o/00 (per thousand) interference fit.

Author Query

How do you prevent the following while tightening to torque the coupling-nut?

  1. Rotor turning while spanner-tightening coupling-nut N5.
  2. Marred dial gauge readings from rotor likely axial travels while tightening N5.
  3. Does not oiling reduce the dry shaft to coupling friction grip factored in torque transmission calculations substantially? Maybe this is one reason for the seen fret corrosion damages
  4. Will not force sliding the tightly fitting coupling over the shaft taper injure the surfaces? Maybe these injuries misled us as fret corrosion

Crews silence on these convinced the author to Root Cause Analyze the problem and finding a solution.

Author Solution

The author concluded one or more of the above led to inadequate grip between the shaft and coupling half bore.

Hence, after considerable thought he developed below given the above deficiencies free procedure:  

  1. Ensure min 80% blue match contact of coupling bore on shaft taper as before
  2. Wipe the blue well. Do not oil the mating parts; rather solvent clean and clean rag wipe both
  3. Fix the CH on the shaft taper, easy spanner-tighten the coupling nut unscrew and save it.
  4. Screw in studs S1 on to a CH hole and S2 on diametrically opposite hole (figure)
  5. Screw in nuts N2 and N4 on the studs till they touch CH face – do not tighten
  6. Placing feelers of total thickness = coupling draw on the shaft end, easy spanner tighten nuts N1 and N3 to touch the feelers and prevent pulling them out.
  7. Tighten nuts N2 & N4 well
  8. Loosen N1 & N3 in 5O increments till able to pull out the feeler assembly. Remove and save the feeler pack
  9. Tighten Locknuts LN well taking care not to disturb N1 and N3
  10. Remove the coupling half and studs assembly from the shaft
  11. Soak the assembly in an 80 to 1000 C higher than room temperature oil bath for 15 minutes
  12. Remove and wipe well coupling bore & shaft taper free of oil.
  13. Push the hot assembly on to the shaft taper until the flat butts on shaft end.
  14. Allow to cool – the coupling fit on the shaft taper is 0.5 0/00 interference
  15. Unscrew the studs from CH and save the parts for future coupling fit ups.
  16. Hand-tighten the coupling nut N5 and with toque wrench confirm adequate torque tightening
Shaft and Coupling Bore Tapers Repair Caused Frequent Shutdowns

Fretting corrosion was history after following the scientific procedure

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

You've successfully subscribed !
Share

Recent Articles

  • PLC Tutorials

VFD Simulator Download – Free Yaskawa V1000 Software

VFD simulator download: Master the online tool from the Yaskawa V1000 & programming software for…

3 days ago
  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

6 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

6 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

6 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

4 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

6 days ago