Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: How does a Redundant Controller comes in line when the Main Controller fails?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > How does a Redundant Controller comes in line when the Main Controller fails?

How does a Redundant Controller comes in line when the Main Controller fails?

Last updated: December 19, 2019 9:44 pm
Editorial Staff
Control Systems Guest Articles
1 Comment
Share
2 Min Read
SHARE

How does a Redundant Controller comes in line when the Main Controller fails in the distributed control system (DCS)?

The Processor Card performs calculations and control computation. In case of Field Control Station (FCS) (simply we can assume as a System Cabinet with Processor cards & other IO cards) with duplexed configuration, there are two processor cards. One of the cards is in control status (main) and the other is in the standby status.

In case of FCS with duplexed configuration, both the processor cards perform control computation.

From the below figure, we have Left Processor Card and Right Processor Card. Again each processor card has two inbuilt processors or CPU, which perform the same control computation (optional feature, some cards may have only one, depends on manufacturer).

By Default, One Processor Card (say Right CPU) will be main and Other (Left) card is in Standby mode during Start-up.

All Inputs & outputs will be shared among the Two Processor Cards (Left & Right). The same program will be downloaded into both Cards (left & Right).

As per below figure, Both Left & Right Processor Cards have two Sub CPU’s inside. The two sub CPU’s in each Processor Card (Left or Right) executes same functions.

A comparator compares the computation results during each computation cycle of these CPU’s. If the results match computation is normal and the data is sent to locations such as the main memory and bus interface unit for further processing to take respective action. If the results do not match, the corresponding processor card will be stopped.

If the error occurs in the active (main) processor card, then switchover to standby card occurs without any interruption to live monitor/control of the plant.

main controller fails

Image Courtesy : Yokogawa

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Redundant Automation Systems – Need and Advantages
Types of Failures in Industrial Automation Systems
Proportioning Feedforward action
Difference between Process shutdown and Emergency Shutdown
Importance of Grounding Electronic Equipment
Compressor Emergency Shutdown Root Cause Analysis
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Vivian says:
    February 19, 2018 at 6:22 am

    How does it know which processor is giving the error signal ?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Difference Between Single Pair Ethernet and Traditional Ethernet
Displacer Level Transmitter Dry Calibration with Weights
Gas Analyzer Sampling System
Commissioning Documents for Instrumentation Engineers
Circular Chart Recorder Calibration Procedure
How to Export Data from DeltaV System to Excel
Readings Mismatch between Field & Control Room ? Why
Top 5 Advantages of Human-Machine Interface (HMI)

Keep Learning

What is Profibus

All About Fieldbus Protocols

2 wire transmitter current loops

2-wire Transmitters Current Loops

Instrumentation Earthing

Instrumentation Earthing

DCS System Cabinet

Yokogawa DCS System Maintenance Procedures

Stroke Checking Procedure for GCV, SRV, IGV, and LFBV

Stroke Checking Procedure for GCV, SRV, IGV, and LFBV

PID Controller Types

PID Controllers : Parallel, Ideal & Series

Heat Exchanger Outlet Temperature Control

Heat Exchanger Temperature Control

4-20mA Loop Power Supply Questions

4-20mA Loop Power Supply Questions and Answers

Learn More

PIN Diode Working Principle

PIN Diode Working Principle

Functional Testing of Control Valve Positioners

Functional Testing of Control Valve Positioners

Microprocessors Objective Questions

Microprocessors Objective Questions – Set 3

4-20ma-formulas-and-examples

4-20mA Formulas and Examples

Rotary Encoder

Rotary Encoder Interview Questions and Answers

Voltage Control & Circuit Breakers Interview Questions

Voltage Control & Circuit Breakers Interview Questions

Tips for Reducing the Noise Signals

Tips for Reducing the Noise Signals

Difference between Absolute, Gauge and Differential Pressure Transmitters

Difference between Absolute, Gauge and Differential Pressure Transmitters

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?