Topology involves the manner in which the fieldbus devices are connected to the data highway. There are several possible topologies that are employed as per the needs of the plant geography.

Fieldbus Network Topologies

Several options employed are as follows: point-to-point, bus with spurs (multidrop), tree or chicken foot, daisy chain, and mixed. For clarity, power supply and terminators are not shown in the Below Figures representing different fieldbus technologies.

Point to Point Topology

Point-to-point topology is illustrated in Below Figure. In this topology, the segment consists of two devices. The two devices could be in the field, or else the device in the field and the host in the control room.

Point to Point Topology

Bus with Spurs

A bus with spurs, also known as multidrop, is shown in Below Figure. The devices are connected to the segment via small cable lengths, called spurs. Spur length can vary between 1 and 120 m.

Tree or Chicken Foot Topology

In this topology, devices on a particular segment are connected via a junction box, marshaling panel, terminal, or I/O card (also called chicken foot).

This scheme is suitable for devices situated in the same geographical place and can be connected to the same junction box and also obeying the rules of maximum spur length per segment. The scheme is shown in Below Figure.

Daisy Chain Topology

This is shown in Below Figure in which the devices are series connected in a particular segment.

Device connections to the segment should be such that dis-connection of a single segment would not lead to total isolation of that segment.

Mixed Topology

A mixed topology embraces more than one topology discussed above, and a possible combination is shown in Below Figure.

Depending on the physical locations of the devices in the plant and the length restrictions for segment lengths, different topologies are employed to derive the advantages of individual topologies.

You've successfully subscribed !
Share

Recent Articles

  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

2 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

2 weeks ago
  • PLC Tutorials

Batch Mixing with PLC Ladder Logic Program

In this example, we will learn batch mixing with PLC ladder logic program using timer…

2 weeks ago
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

2 weeks ago
  • PLC Tutorials

PLC Programming Example with Pushbutton and Motor

In this article, you will learn the PLC programming example with pushbutton and motor control…

3 weeks ago
  • PLC Tutorials

Boolean Logic to PLC Programming

This article teaches how to convert Boolean logic to PLC programming ladder logic with the…

1 month ago