Beam Detectors Working Principle Animation

Beam Detectors Working Principle Animation

Beam Detectors Working Principle:

A Beam Detector has two main parts

1. Source like IR LED, LASER, or any type.

2. Detector like Photodiode etc.

An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas, typically as an indicator of fire. They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical or restricted for use by the height of the building. Optical beam smoke detectors are often installed in warehouses as a cost effective means of protecting large open spaces

Optical beam smoke detectors work on the principle of light obscuration, where the presence of smoke blocks some of the light from the beam,typically through either absorbance or light scattering. Once a certain percentage of the transmitted light has been blocked by the smoke, a fire is signalled. Optical beam smoke detectors are typically used to detect fires in large commercial and industrial buildings, as components in a larger fire alarm system.

Also Read: Gas Detectors Working Principles

Optical beam smoke detectors consist of at least one light transmitter and one receiver, which is photosensitive. The photosensitive receiver monitors light produced by the transmitter under normal conditions. In the absence of smoke, light passes from the light transmitter to the receiver in a straight line. In a fire, when smoke falls within the path of the beam detector, some of the light is absorbed or scattered by the smoke particles.This creates a decrease in the received signal, leading to an increase in optical obstruction i.e. transmittance of light across the beam path and which in turns a output signal showing smoke/fire indication.

The optical beam smoke detectors were prone to false alarms, which were caused by many different factors. Most commonly, the build-up of dust, dirt and other debris would lower the detection threshold for the detector, causing the system to enter alarm when no fire was present.

Optical beam smoke detectors Working Principle

Also Read:Interview Questions on Smoke Detectors

You've successfully subscribed !

View Comments

Share

Recent Articles

From Boolean Algebra to PLC Logic
  • PLC Tutorials

From Boolean Algebra to PLC Logic

In this article, a simple example will teach you the conversion from Boolean algebra to…

1 month ago
  • PLC Tutorials

PLC Cooking Timer Example for Kitchen Automation

In this article, you will learn the PLC cooking timer example for kitchen automation using…

3 weeks ago
  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

3 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

3 weeks ago
  • PLC Tutorials

Batch Mixing with PLC Ladder Logic Program

In this example, we will learn batch mixing with PLC ladder logic program using timer…

2 weeks ago
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

3 weeks ago