Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: 100 Electromagnetic Motor Starters Multiple Choice Questions
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical MCQ > 100 Electromagnetic Motor Starters Multiple Choice Questions

100 Electromagnetic Motor Starters Multiple Choice Questions

Electrical engineering quiz questions and answers on electromagnetic motor starters, overload relay, and hand-off-Automatic (H-O-A) control of a 3-phase AC motor.

Last updated: January 9, 2022 10:25 am
Editorial Staff
Electrical MCQ
No Comments
Share
7 Min Read
SHARE

Electrical engineering quiz questions and answers on electromagnetic motor starters, overload relay, auxiliary control contacts, two-wire control, motor control ladder diagrams, and hand-off-Automatic (H-O-A) control of a 3-phase AC motor,

Electromagnetic Motor Starters Questions

Quiz on Manual Motor Starters

Question 1:

The _______ auxiliary contacts can also be used to ________ the 3-pole electromagnetic motor-starter of a second motor when two motors cannot be operated simultaneously.

A) NC; lock-in
B) NO; lockout
C) NC; lockout
D) NO; lock-in

Question 2:

In the basic 3-wire control circuit of a 3-phase AC motor using a 3-pole electromagnetic motor -starter, two individual PB switches are required:

The _________ PB switch serves to initiate a run condition of the motor and must be wired in parallel with a set of _________ auxiliary contacts on the motor-starter to seal in the start action.

A) NO Start; NC
B) NC Start; NO
C) NC Start; NC
D) NO Start; NO

Question 3:

If the NC Stop PB switch is held open (depressed), activating (closing) the NO Start PB switch will not initiate the control function: the circuit is disabled.

This method of control lockout (referred to as _________ switching) is often used to prevent a 3-phase AC motor from being started during a process cycle.

A) none of the answers
B) unlocked-stop
C) locked-start
D) locked-stop

Question 4:

The use of momentary-type selector or pushbutton switches in a ladder diagram is normally limited to _________ control.

A) 3-wire
B) 4-wire
C) 1-wire
D) 2-wire

Question 5:

Low- or no-voltage _________ is characteristic of 2-wire control.

A) protection
B) none of the answers
C) example
D) release

Question 6:

When a 3-wire control consists of two PB switches wired in series, the _______ momentary PB switch is used as the interrupt or stop switch.

The _______ momentary PB switch is used as the initiate or start switch.

A) NC; NC
B) NO; NO
C) NC; NO
D) NO; NC

Question 7:

The term ______________ describes any control operation in which a function, motion, or operation can be caused either to occur (lock-in) or to be prevented from occurring (lock-out), simultaneously with another function, motion, or operation.

A) overload
B) lock
C) interlock
D) relay

Question 8:

In the basic 3-wire control circuit of a 3-phase AC induction motor that uses a full-voltage motor -starter, two individual PB switches are required.

The two individual PB switches must be wired in _______.

Continuous control-voltage or control power is normally applied to the __________ PB switch, which serves to interrupt the start or run condition of the motor.

The __________ PB switch, which serves to initiate a run condition of the motor, must be wired in parallel with a set of __________ auxiliary contacts on the motor-starter to seal in the start action.

A) series; NO Start; NC Stop; NO
B) series; NC Stop; NO Start; NO
C) series; NC Stop; NO Start; NC
D) parallel; NC Stop; NO Start; NO
E) parallel; NO Start; NC Stop; NO
F) parallel; NC Stop; NO Start; NC

Question 9:

_____________ control of a 3-phase AC induction motor, by means of an electromagnetic motor -starter, uses momentary switches with either pushbutton- or selector-type operators.

A) single-wire
B) four-wire
C) Three-wire
D) Two-wire

Question 10:

In troubleshooting a motor control circuit, ___________ measurements, with the power on, are normally the preferred method.

A) Either resistance or voltage
B) voltage
C) resistance
D) wattage

Question 11:

The mechanical closing of the power contacts in a 3-phase full-voltage motor starter is accomplished by mechanical linkage and a concentrated electromagnetic field.

The field is produced by a coil contained in the motor-starter solenoid.

A) True
B) False

Question 12:

When two motors are controlled with a 3-position selector switch, the control or run status of the two motors are interlocked with the single switch.

If both motors are to be OFF in the center position of the switch, then both sets of contacts should be at-rest in their ________ configuration.

________ is commanded to start when the switch is turned to the left position. __________ is commanded to start when the switch is turned to the right position.

A) NO; Motor 2; Motor 1
B) NC; Motor 2; Motor 1
C) NC; Motor 1; Motor 2
D) NO; Motor 1; Motor 2

Question 13:

When two or more sets of contacts are controlled (opened or closed) simultaneously by a 2-position, maintain-type selector switch, the switch is further described as a ________ switch.

A) stack
B) sequential
C) Either sequential or slider
D) slider

Question 14:

Regarding grounded or ungrounded circuit conductors, individual wires in a control circuit must color-coded.

They must be further identified with an effective wire-numbering system.

The two side rails of the ladder diagram are referred to as the control-power busses.

The load side of the fuse in the ______ circuit conductor is identified as wire #1.

The ______ circuit conductor (circuit common) is identified as wire #2.

A) grounded; ungrounded
B) ungrounded; ungrounded
C) ungrounded; grounded
D) none of the answers

Question 15:

The term interlock describes any control operation in which a function, motion, or operation can be caused either to occur ________ or to be prevented from occurring _________, simultaneously with another function, motion, or operation.

A) lock-in; lock-in
B) lock-out; lock-in
C) lock-out; lock-out
D) lock-in; lock-out

Click on the below button to launch the Quiz. Each question carries 1 mark. You have to score 50% of the marks to pass the test.

All 100+ questions and answers are available in the Quiz.

Instrumentation Quiz

Share your suggestions through the comments section.

This work was created by Marco Gotshaw and is licensed under a Creative Commons Attribution 4.0 International License.

If you liked this article, then please subscribe to our YouTube Channel for Electrical, Electronics, Instrumentation, PLC, and SCADA video tutorials.

Next Quiz:

  • Electrical Meters Quiz
  • Electrical Symbols Quiz
  • Transformers Quiz
  • Equipment Grounding Quiz
  • Circuit Breaker Quiz
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Synchronous Machines EMF Polygon Questions
Top 50 Electrical Switch Questions and Answers
Electric Circuits Objective Questions – Set 6
Power Systems MCQ Series 3
Permanent Magnet DC Motor (PMDC) Questions
Synchronous Machine Quiz
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Ohms Law Objective Questions and Answers
Electrical Welding Multiple Choice Questions and Answers (MCQ)
Electrical Machines Losses and Efficiency MCQ
Starting of Polyphase Induction Motors Quiz
125+ Alternator Objective Questions and Answers
Ideal Two Winding Transformer
Electrical Machines MCQ Series 19
Electrical Machines MCQ Series 14

Keep Learning

Electrical Machines Objective Questions

Electrical Machines MCQ Series 18

Quiz on Electrical Meters and Measurement

200+ Quiz on Electrical Meters, Measurement, and Troubleshooting

Heating and Welding Objective Questions

Heating and Welding Objective Questions

HVAC Multiple Choice Questions

HVAC Multiple Choice Questions

Electrical Machines Questions and Answers

Synchronous Motors Power and Torque Questions

Electromagnetic Fields Objective Questions

Electromagnetic Field Test Questions

Electrical Machines Questions and Answers

Synchronous Machines Flux and MMF Phasors Questions

Electrical Machines Questions and Answers

Transformer as a Magnetically Coupled Circuit

Learn More

Temperature Measurement Interview

Temperature Measurement Interview Questions

Feedback control loop - 2

Feedback Control Principle

Cooling Water Circulating Pump Low throughput

Cooling Water Circulating Pump Low throughput Resolved

Boiler Feed Water Circulation System

Boiler Feed Water Circulation System

Vision Camera System

Vision Camera Systems in Industrial Automation

Power Electronics Objective Questions

Applications of Power Electronics MCQ

Two Wattmeters to Measure 3 Phase Power

Three Phase Wattmeter

FIFO in STL Language in Siemens PLC

How to Code a FIFO Queue in STL Language in Siemens PLC?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?