Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Float-type Level Switch for Sensing Low Oil Level
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Float-type Level Switch for Sensing Low Oil Level

Float-type Level Switch for Sensing Low Oil Level

An oil sump for a hydraulic system is equipped with a float-type level switch for sensing low oil level but it gives faulty signals.

Last updated: January 27, 2021 11:10 am
Editorial Staff
Practical Questions
1 Comment
Share
2 Min Read
SHARE

An oil sump for a hydraulic system is equipped with a float-type level switch for sensing low oil level and providing automatic shut-down capability for the hydraulic system:

Contents
Float-type Level SwitchAnswer

Float-type Level Switch

Float-type Level Switch for Sensing Low Oil Level

The flow rate of oil through the sump is quite high, and this presents a problem.

With the oil being so turbulent, the float does not rest gently on the oil’s surface.

Instead, it is tossed to and fro on the choppy surface, which can make the level switch “think” the float has gone down further than it actually has, thus causing needless shutdowns.

One solution to this problem is a stilling well. Describe what a “stilling well” is, how you might make one for this application, and why it works to prevent the problem.

Answer

A stilling well is a vertical pipe placed in the process liquid, designed to produce a calm (“still”) liquid surface for a level-sensing instrument to measure.

They are especially useful when sensing the level of a flowing stream of liquid, where anything placed within that flowing stream will be pushed laterally by the force of the moving liquid.

Float Level Switch on Oil Sump

A simple piece of pipe works great as a stilling well.

One must take precautions that the float cannot get “hung up” inside the pipe, but otherwise the selection and installation of the pipe should be rather simple.

Would an ultrasonic level switch be immune to the turbulence? Explain why or why not.

Share your answers & explanation with us through the below comments section.

Read Next:

  • Open Tank Level Measure
  • Level Transmitter Errors
  • Practical Level Sensors
  • Sump Tank Level Transmitter
  • Guided Wave Radar Level Sensor

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

A Question on Steam Drum Water Level Measurement
Solenoid Valves Questions & Answers – 3
Calculate the Thermocouple Output millivolts
Determine LRV and URV settings for the Level Transmitter
Simulate Different Values for Pressure Instrument Under Test
Programmable Logic Controller (PLC) Questions and Answers – 11
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Nikita Kotkar says:
    January 27, 2021 at 1:12 pm

    Yes.ultrasonic level sensor can immune turbulance.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

PLC Program to Control a Water Pump
Programmable Logic Controller (PLC) Questions and Answers – 1
Type E thermocouple Calculations
How Do You Connect the Differential Pressure Gauge at the Filter?
Pressure Level Transmitter Problems
Transmitter Calibration Range of a Vessel Level
Practical Process Control System Questions & Answers – 7
How Manometer Measures Differential Pressure for Different Fluids?

Keep Learning

Identify Instrumentation Terms in Water Supply System

Identify Instrumentation Terms in Water Supply System

Programmable Logic Controller (PLC) Questions and Answers

Programmable Logic Controller (PLC) Questions and Answers – 4

Siemens PLC Block Diagram

Programmable Logic Controller (PLC) Questions and Answers – 14

pressure switch ladder-logic diagram

Draw the appropriate Pressure Switch Symbol ?

Drum Level differential pressure transmitter

Calculate Differential Pressure Sensed by Level Transmitter

compressor emergency shutdown system

Compressor Emergency Shutdown Root Cause Analysis

Calculate Temperature of RTD

Calculate Temperature of RTD

Allen-Bradley PLC Program

Troubleshoot Allen Bradley PLC Logic

Learn More

Baffle Nozzle Question

Baffle Nozzle Question

How to Create DFB in Schneider PLC? – Derived Function Block

Programmable Logic Controller (PLC) Questions and Answers

PLC Ladder Logic Questions and Answers

Electrical Machines Questions and Answers

Transformer Phasor Diagram

Probe Type Radar Level Transmitter

Contact Type Guided Wave Radar Level Transmitter Working Principle

field-mounted thermocouple

Thermocouple Extension Wires

What are HP and LP Switches in HVAC

What are HP and LP Switches in HVAC?

Ball Valve Pictures

How Ball Valves Work ?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?