Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Air Compressor Control Circuit Problem
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Air Compressor Control Circuit Problem

Air Compressor Control Circuit Problem

The air compressor control circuit has a problem and unable to start even when the air pressure is zero PSI.

Last updated: October 23, 2020 11:20 am
Editorial Staff
Practical Questions
No Comments
Share
3 Min Read
SHARE

This air compressor control circuit has a problem. The air compressor refuses to start even when the air pressure is zero PSI.

Air Compressor Control Circuit

Air Compressor Control Circuit has a Problem

A technician begins diagnosing the circuit, following the steps shown (in order):

Test 1: Measured 120 VAC between points A and C, with “Hand/Off/Auto” switch in the “Auto” position.

Test 2: Measured 120 VAC between points A and D, with “Hand/Off/Auto” switch in “Auto” position.

Test 3: Measured 0 VAC between points E and C, with “Hand/Off/Auto” switch in “Auto” position.

Test 4: Jumpered points A and B, with “Hand/Off/Auto” switch in “Auto” position. The motor did not start.

Identify any useful information about the nature or location of the fault derived from the results of each test, in order of the tests performed. If the test is not useful (i.e. provides no new information), mark it as such.

Assuming there is only one fault in the circuit, identify the location and nature of the fault as precisely as you can from the test results shown above.

Answer:

Test 1: Measured 120 VAC between points A and C, with “Hand/Off/Auto” switch in the “Auto” position. Proves there is 120 VAC control power available, that the fuse is good, and that the Hand/Off/Auto switch is passing power through to point A.

Test 2: Measured 120 VAC between points A and D, with “Hand/Off/Auto” switch in “Auto” position. Proves there is an “open” fault somewhere between those points, in one of the two switches, and that we do not have any other “open” faults in the contactor coil circuit.

Test 3: Measured 0 VAC between points E and C, with “Hand/Off/Auto” switch in “Auto” position. This is an unnecessary test, as we already know there is continuity through the overload contact.

Test 4: Jumpered points A and B, with “Hand/Off/Auto” switch in “Auto” position. The motor did not start. Combined with the results of previous tests, this test proves the “open” fault must lie between points B and D: namely the PSH.

The fault is an “open” high pressure switch (PSH), or in the wires connecting the PSH to points B and D.

Share your answers with us through the below comments section.

Read Next:

  • Compressor Seal Oil System
  • PLC Compressor Logic
  • Instrument Air Compressor
  • Liquid Level Switch Control
  • PLC Water Level Control Logic

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Instrument Lab Exercise – Ranging and Manometer Usage
Level Measurement Lab Exercise
Transmitter Calibration Range of a Vessel Level
Practical Process Control System Questions & Answers – 9
Upgrading the Electrical System in an Automobile
Thermocouple Terminal block Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

PLC Pump Permissive Interlocks
Troubleshoot Allen Bradley PLC Logic
Question on Analytical Controller
How Do You Connect the Differential Pressure Gauge at the Filter?
Electric-driven Air Compressor Troubleshooting
LRV and URV of PT for Extreme Limits of Empty and Full
Solenoid Valves Questions & Answers – 4
DP Transmitter Calibration Errors

Keep Learning

A span error with wrong slope

Determine the Instrument Calibration Error

Resistance Temperature Detector (RTD) Questions

Resistance Temperature Detector (RTD) Questions – 1

liquid flow control loop

Liquid Flow Control Loop Controller Action

Practical Process Control System Questions

Process Control Loop Testing

Inclined Water Manometer

How much Pressure is applied to Inclined Water Manometer?

float-type level switch control a pump

Float-type Level Switch to Control a pump

Calculation of Hydrostatic Pressure

Calculation of Hydrostatic Pressure

Programmable Logic Controller (PLC) Questions and Answers

Programmable Logic Controller (PLC) Questions and Answers – 7

Learn More

SCADA

Top 100+ SCADA Questions

Heat Flow Balance Systems Objective Questions

Heat Flow Balance Systems Objective Questions

What is Transformer Bushing

What is Transformer Bushing? Working Principle

Advantages and Disadvantages of Network Topology

Advantages and Disadvantages of Per Unit System

How to Upload PLC Program in Siemens PLC if Upload Icon is Disabled

Upload Option Disabled in Siemens PLC

PLC Program for fan control unit system

PLC Programming for Fan Control Unit System for Industry

Tank car bonding at siding

Electrical Static Grounding Techniques

Digital Electronics Multiple Choice Questions

Transistor Transistor Logic (TTL) Objective Questions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?