Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: What is Live Zero in 4-20 mA Current Loop ?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Basics > What is Live Zero in 4-20 mA Current Loop ?

What is Live Zero in 4-20 mA Current Loop ?

Last updated: March 4, 2021 3:24 pm
Editorial Staff
Basics PLC Tutorials
1 Comment
Share
3 Min Read
SHARE

The popular myth about 4-20 mA, debunked.

A lot of C&I practitioners (including me) has long believed that the establishment of 4 mA as the lower range of the widely used analog current is due to the fact that at fault condition, the electronic signal will always fall to 0 mA. Hence, the creation of the term “live zero.”

Live Zero in 4-20 mA Current Loop

Yes, an electronic signal may really fall to zero at certain fault circumstances e.g. disconnection between the transmitter and analog card receiver, but it is also possible to rise at 20 mA or at certain locking intermediate value given the fact that a lot of electronic transmitters now are “smart” which means that they can have self-diagnostic capabilities, allowing them to be programmed to assume a worst case deviation value. Chances are it won’t be 0 mA given a certain goal of a process during fault detection.

The viable reason behind the use of this “live zero” has hardly anything to do with failure. A live zero provides a minimum current for the signal source which enables the device to be powered from the receiver.

A term which we may have heard of called “two-wire transmission” defines this scenario and it eliminates the requirement of another pair of conductors to serve as the power source of a transmitter.

Figure 1 shows a transmitter operating on a “dead-zero” range such as the legacy 0-10 mA standard. This requires the provision of power supply connections to the device so four conductor wires are required for each transmitter.

0 to 10 mA Current Loop

Figure 1: Without the “live zero” transmission

With a live zero, in Figure 2, the transmitter circuitry can already be powered from the receiver itself and only two conductor wires are required.

4 to 20 mA Current Loop

Figure 2: Two-wire transmission with “live zero”

Author: Jeremiah Cayondong

Profile: Linkedin

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • 4-20mA Transmitter Signals
  •  3-15 psi, 10-15 mA, and 4-20 mA
  • Electronic Diagrams Schematics
  • Instrument Zero & Span Errors
  • HART Communicator Questions
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Types of Limit Switches – Principle, Advantages, Disadvantages
PLC Program for Star Delta Motor Starter
Communicating Delta PLC Software to Simulator
Statement List (STL) to Find Highest Value
PLC based Metro Automation Project
Difference between Transmitter and Transducer with Examples
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Er Athar Sheikh says:
    March 11, 2022 at 9:55 pm

    Many instrumentation manufacturers produce 4–20 mA sensors which are loop powered The live or elevated zero of 4 mA allows powering of the device even with no process signal output from the field transmitter The accuracy of the signal is not affected by voltage drop in the interconnecting wiring.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is a Data Block? Global Data Blocks in PLC
Tanks Draining Control in PLC using Functional Block Diagram
PLC Timer Programming Examples – TON, TOF, TP and TONR
Main differences between Sinking and Sourcing Circuits
#10 PLC Best Practices – Assign Register Blocks by Function
Doll Claw Machine using Omron PLC Programming
PLC Alarm and Trip Documentation
Automation System for Hazardous Environments

Keep Learning

PLC programming for liquid mixing application code

PLC Mixing Logic in Liquids on EcoStruxure Machine Expert-Basic

Hardwired IO and Serial IO - Differences Explained

Hardwired I/O and Serial I/O – Differences Explained

PLC program pushbutton switches

PLC Permissive for Motor Control

Download Free Robotics Software

Step by Step Guidelines to Download Free Robotics Software

PLC Program for Control Valve Scaling

PLC Program for Control Valve Scaling

Basics of PID Controllers

PID Controllers in Closed Loop Control Systems – PLC Basics

Single Line Diagram of UPS System

UPS Selection Factors for a Control System

Control Methods in Servo Motor Drives

Various Control Methods in Servo Motor Drives

Learn More

How to troubleshoot the PLC Hardware faults

Hardware Troubleshooting Steps for PLC Automation Systems

Microwave Barrier Level Switch Working Principle

Transformer voltage and turns ratio

Transformer Current Ratio

Stepper Motors Objective Questions & Answers

Stepper Motors Objective Questions & Answers

Two Differential Pressure Transmitters

Pressure Level Transmitter Problems

Nuclear Magnetic Resonance Spectrometer Questions and Answers

Continuous Wave NMR Spectroscopy Questions & Answers

Instrumentation Commissioning

Commissioning Documents for Instrumentation Engineers

Solenoid Actuated Valves

Solenoid Actuated Valves

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?