Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Fire and Gas system Audible and Visual Alarms
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Fire & Gas System > Fire and Gas system Audible and Visual Alarms

Fire and Gas system Audible and Visual Alarms

Last updated: January 23, 2019 10:45 pm
Editorial Staff
Fire & Gas System
No Comments
Share
4 Min Read
SHARE

A fire alarm system has a number of devices working together to detect and warn people through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present.

Contents
Selection Criteria for Audible and Visual AlarmsArticles You May Like :What is Alarm Management System ?What is a Mimic Panel ?Importance of Fire & Gas DetectionArgonite Fire Suppression SystemFire Alarm System Questions

These alarms may be activated automatically from smoke detectors, and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points or pull stations.

Alarms can be either motorized bells or wall mountable sounders or horns. They can also be speaker strobes which sound an alarm, followed by a voice evacuation message which warns people inside the building not to use the elevators.

Fire alarm sounders can be set to certain frequencies and different tones including low, medium and high, depending on the country and manufacturer of the device.

A fire alarm system component with discrete identification that can have its status individually identified or that is used to individually control other functions.

Selection Criteria for Audible and Visual Alarms

Following are some minimum requirement applicable for Audible and Visual Alarms (Addressable Devices) selection, however requirements vary from industry to industry.

The audible and visual alarm shall be compatible with the fire and gas system panels from which it is connected to have automatic initiation from the panel.

The units shall be of wall/ceiling/floor mounting type to meet the installation requirements.

Audible alarms shall be rated for continuous operation.

Audible alarms used for Fire and Gas system shall be 0f low current consumption.

Audible alarms for Fire and Gas system shall be distinguishable from audible alarms used for other purposes. The audio signal shall be 0f different tones for fire, combustible gas and toxic gas alarms.

Audible signal appliances intended for of peration in the public mode shall have a sound level of not less than 85 dBA at 3 m or more than 120 dBA at a minimum hearing distance from the audible appliance.

To ensure that audible public mode signals are clearly heard, they shall have a sound level at least 15 dBA above the average ambient sound level or 5 dBA above maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 1.5m above the floor in the occupied area. (The average ambient sound level used for design guidance in mechanical equipment rooms shall be 85 dBA or actual measured value , whichever is higher).

Alarms mounted outside the central control facility shall be audible in all areas of the facility.

A manual operation should be required to silence the alarm. The alarm shall not be automatically silenced or canceled.

Visual alarms shall be capable of continuous operation without adverse effects.

The colour of the transmitted Iight, power output and operation shall be such that it is clearly visible from all areas it covers and readily discernible against artificial lighting internally and sunlight externally.

Visual alarms which uses tungsten lamps shall use lamps underrun to ensure maximum life. long-life, high-quality lamps to the latest technology shall be used.

Warning flashing fire alarm beacons provided for high noise level areas to compliment the audio alarms shall be complete with xenon strobe light (Red lens) and totally enclosed solid state circuitry.

The audio and visual alarms shall be rated to operate on a nominal voltage of 24V DC unless otherwise specified.

Articles You May Like :

What is Alarm Management System ?

What is a Mimic Panel ?

Importance of Fire & Gas Detection

Argonite Fire Suppression System

Fire Alarm System Questions

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Fire and Gas System Interview Questions & Answers
Objective Questions of Building Fire and Gas Detectors
Gas Detectors Interview Questions & Answers
What is Gas Suppression Systems ?
Lower Explosive Limit (LEL)
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Difference Between Passive and Active Fire Protection

Active and Passive Fire Protection

Fire Hydrant System

Basics of Fire Fighting Hydrant Systems

Deluge System for Transformer Protection

Deluge System for Transformer Protection Animation

Rate Compensated Heat Detectors Working Principle

Rate Compensated Heat Detectors Working Principle

Gas Detectors Location Installation

Gas Detectors Installation Techniques

Deluge Valve Operation using Solenoid Valve Animation

Deluge Valve Operation

MOS Gas Sensor Principle

MOS Type Gas Sensor Principle

Fixed Gas Detectors vs. Portable Gas Detectors

Fixed Gas Detectors vs. Portable Gas Detectors

More Articles

Communication between Intouch Scada and Allen Bradley PLC

Communication between InTouch Scada and Allen Bradley PLC

Pulsed Fluorescence SO2-H2S-CS Analyzer Working Principle

Pulsed Fluorescence SO2, H2S, CS Analyzer Working Principle

Variable-speed motor controls

Variable Motor Speed Control

Under and Over-Capacity Control Valve

Under and Over-Capacity Control Valve Pose Poor Controllability

How to Locate Faults in Cables? - Fault Analysis and Location

How to Locate Faults in Cables? – Fault Analysis & Location

Instrument Zero and Span Calibration

Instrument Zero and Span Calibration

Moving Coil Type Velocity Transducer

Moving Coil Type Velocity Transducer

Loss in Weight Liquid PLC System

Dosing Pump PLC Logic

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?