Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: How to Select a Pressure Gauge
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation Design > How to Select a Pressure Gauge

How to Select a Pressure Gauge

Last updated: November 13, 2017 5:38 am
Editorial Staff
Instrumentation Design
2 Comments
Share
4 Min Read
SHARE

Seven Steps to Select a Pressure Gauge

1. ACCURACY

Pressure Gauge Accuracy

For a mechanical pressure gauge, accuracy is defined as a percentage of the full-scale range. While requirements differ from one industry to another, the following are general guidelines:

• Test Gauges and Standards: 0.25% through 0.10% full scale accuracies.

• Critical Processes: 0.5% full scale accuracy.

• General Industrial Processes: 1.0% accuracy. Less Critical Commercial Uses: 2.0% accuracy.

Refer to ASME B40.100 for more information on accuracy.Pressure Gauge Dial Size

2. DIAL SIZE

Pressure gauge dial sizes range from less than 1˝ to 16˝ diameters. Generally, readability require- ments, space limitations and required gauge accuracy determine dial size. Accuracies of 0.25% or 0.5% generally have dial sizes of 41 ⁄2˝ or larger since more dial graduations are required.

3. CASE STYLE / MATERIAL

Environmental considerations include ambient temperature, air-borne particulate, condensation, humidity, water and chemicals, all of which can affect gauge performance.Pressure Gauge Case Style

Ambient temperature may affect the accuracy and integrity of the gauge. Gauges are available either temperature compensated or non-temperature compensated. Ambient conditions may require that the gauge be isolated from temperature extremes. When required, the gauge should be isolated from temperature extremes with a flexible line assembly.

When ambient conditions are corrosive, contain a large number of particulate or if the gauge will be exposed to a wet or humid environment like humidity, wash-downs or rain, specify a gauge that is weatherproof/hermetically sealed or liquid filled.

4. MEDIA / WETTED PARTS

Pressure Gauge Wetted Parts

The wetted parts of the pressure gauge, the Bourdon tube and socket must be compatible with the process media. If not compatible with the wetted parts of the gauge, corrosion will occur. Corrosion of gauge wetted parts will eventually cause gauge failure and possibly safety issues. When the gauge wetted parts are not compatible with the process media, a diaphragm should be considered.

5. CONNECTION SIZE

Pressure Gauge Connection Size

Gauges are available with a variety of connections including NPT, DIN, JIS, BSP & SAE. Process pressure gauges with 41 ⁄2˝ dial sizes or larger are most often supplied with a 1 ⁄2˝ NPT connection to best support the gauge. Factors to consider when selecting a pressure gauge connection include process pressures, gauge size and weight, space limitations, leak integrity, and past experience.

6. CONNECTION LOCATION

Pressure gauge Connection Location

Consider the following mounting options when selecting a pressure gauge:

• Stem mount lower connect

• Wall/surface mount lower connect

• Panel mount back connect

• U-clamp flush mount back connect, for panel mounting

• Front flange flush mount back connect, for panel mounting

7. PRESSURE RANGESPressure Gauge Range

ASME B40.100 recommends that normal operating pressure be confined to 25%-75% of the scale. If pulsation is present in the process, maximum operating gauge pressure should not exceed 50% of the full-scale range.

CONCLUSION

To properly select a pressure gauge, consider the gauge process, range, environment, accuracy, dial size, connection and mounting requirements.

Also Read: Working Principle of Pressure Gauge

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
15 Loop Diagram Questions
Difference Between a Flow Control & a Needle Valve
5 Most Common Mistakes When Specifying Valves
What is Material Take Off (MTO)? – Purpose, Components, Uses
System Architecture and Process Control Systems Philosophy
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • anas says:
    February 1, 2016 at 4:16 pm

    i need video tutorial? can you help me?

    Reply
  • S.h.a says:
    April 22, 2017 at 3:03 pm

    good deal

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

Differences between No-load Supply Current and Load Current

Differences between No-load Supply Current and Load Current

Variable Area Flow Meters

All About Variable Area Flow Meters

Field Instruments Scaling and Unit Conversions

Field Instruments Scaling and Unit Conversions

Design & Construction of Process Plant

Process Control Systems Philosophy Concept

simple latching motor control circuit

Motor Control Circuit Wiring

Avoid Process Downtime With Five Device Protection Considerations

How to Avoid Process Downtime ?

Gas Detectors Location Installation

Gas Detectors Installation Techniques

System Architecture in Industrial Automation

How to Design a System Architecture in Industrial Automation?

More Articles

Calibration and Troubleshooting of Oxygen Analyzer

Calibration and Troubleshooting of Oxygen Analyzer

span gas cylinders

Analyzer Sample Systems

Ultrapure Water in the Semiconductor Industry

Ultrapure Water in the Semiconductor Industry

Power Electronics Objective Questions

Three-Phase Rectifier Quiz

What is RTD Sensitivity ?

What is RTD Sensitivity ?

CRA Module in Schneider PLC

CRA Module in Schneider PLC – Remote IO Adapter Module

Vibration Sensors Theory

How Vibration sensors Work ?

Digital Image Processing Projects - DIP Project Ideas

600+ Digital Image Processing Projects – DIP Project Ideas

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?