Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Ionization chamber Principle
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Analyzers > Ionization chamber Principle

Ionization chamber Principle

Last updated: June 4, 2018 5:02 pm
Editorial Staff
Analyzers
No Comments
Share
4 Min Read
SHARE

The ionization chamber is the simplest of all gas-filled radiation detectors, and is widely used for the detection and measurement of certain types of ionizing radiation; X-rays, gamma rays and beta particles. Conventionally, the term “ionization chamber” is used exclusively to describe those detectors which collect all the charges created by direct ionization within the gas through the application of an electric field. It only uses the discrete charges created by each interaction between the incident radiation and the gas, and does not involve the gas multiplication mechanisms used by other radiation instruments, such as the Geiger-Müller counter or the proportional counter.

Ion chambers have a good uniform response to radiation over a wide range of energies and are the preferred means of measuring high levels of gamma radiation. They are widely used in the nuclear power industry, research labs, radiography, radiobiology, and environmental monitoring.

Principle of operation

An ionization chamber measures the charge from the number of ion pairs created within a gas caused by incident radiation. It consists of a gas-filled chamber with two electrodes; known as anode and cathode. The electrodes may be in the form of parallel plates (Parallel Plate Ionization Chambers: PPIC), or a cylinder arrangement with a coaxially located internal anode wire.

Ionization chamber Working

Figure : Schematic diagram of parallel plate ion chamber, showing drift of ions. Electrons typically drift 1000 times faster than positive ions due to their much smaller mass.

A voltage potential is applied between the electrodes to create an electric field in the fill gas. When gas between the electrodes is ionized by incident ionizing radiation, ion-pairs are created and the resultant positive ions and dissociated electrons move to the electrodes of the opposite polarity under the influence of the electric field. This generates an ionization current which is measured by an electrometer circuit. The electrometer must be capable of measuring the very small output current which is in the region of femtoamperes to picoamperes, depending on the chamber design, radiation dose and applied voltage.

Each ion pair created deposits or removes a small electric charge to or from an electrode, such that the accumulated charge is proportional to the number of ion pairs created, and hence the radiation dose. This continual generation of charge produces an ionization current, which is a measure of the total ionizing dose entering the chamber. However, the chamber cannot discriminate between radiation types (beta or gamma) and cannot produce an energy spectrum of radiation.

The electric field also enables the device to work continuously by mopping up electrons, which prevents the fill gas from becoming saturated, where no more ions could be collected, and by preventing the recombination of ion pairs, which would diminish the ion current. This mode of operation is referred to as “current” mode, meaning that the output signal is a continuous current, and not a pulse output as in the cases of the Geiger-Müller tube or the proportional counter.

Referring to the accompanying ion pair collection graph, it can be seen that in the “ion chamber” operating region the collection of ion pairs is effectively constant over a range of applied voltage, as due to its relatively low electric field strength the ion chamber does not have any “multiplication effect”. This is in distinction to the Geiger-Müller tube or the proportional counter whereby secondary electrons, and ultimately multiple avalanches, greatly amplify the original ion-current charge.

Ionization chamber Principle

Figure : Plot of ion current against voltage for a wire cylinder gaseous radiation detector. The ion chamber uses the lowest usable detection region.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Humidity Measurement Principle
Troubleshooting pH Analyzer Common Problems
What is Gas Metering System?
Conductivity Transmitter Calibration Procedure
Gas chromatograph Working Animation
Automated Calibration
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Humidity Sensor Working Principle
pH Analyzer Interview Questions and Answers
Top 100 Analytical Instrumentation Engineering Projects
Industrial Applications of Chromatographs
Basics of Chromatograph Operation
Online Gas Chromatograph Principle
Scintillation Counter Principle
Oxygen Analyzer Working Principle

Keep Learning

Turbidity Analyzer Working Principle

Turbidity Analyzer Working Principle

Conductivity Analyzer Principle

Conductivity Analyzers Interview Questions & Answers

Chemiluminescent Analyzer

Chemiluminescence

Chlorine dioxide measurement principle

Chlorine dioxide Analyzer Principle

Hair Hydrometer Principle

Hair Hydrometer Principle

Ph Meter Principle

pH measurement

process gas chromatographs

Multi Column Gas Chromatograph

Analytical Standards

Learn More

Omron PLC Example

Design a Water Pump PLC Program using CX-Programmer

What is a Differential Mode Signal

Difference Between Differential Mode and Common Mode

PLC Program to Control Level of Two Tanks

PLC Level Control of Two Tanks

Basics of Thermistors, Thermocouples and RTD's

Basics of Thermistors, Thermocouples and RTD’s

Feedback Characteristics of Control Systems

Feedback and Non-feedback Systems Objective Questions

PLC Totalizer

PLC Program for Flow Totalizer

Magnetic Level Indicator

Magnetic Level Indicator Principle, Limitations, Installation and Calibration

Electrical Machines Questions and Answers

Compensation Winding Quiz

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?