Reading: Resistance Temperature Detector (RTD) Questions – 2
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Resistance Temperature Detector (RTD) Questions – 2

Resistance Temperature Detector (RTD) Questions – 2

Last updated: June 6, 2018 9:49 am
Editorial Staff
Practical Questions
No Comments
Share
1 Min Read
SHARE

Resistance Temperature Detector (RTD) Questions 

Calculate the voltage across the bridge (VAB) at the following RTD temperatures, assuming a 604 Ω nickel-iron RTD with an alpha value of 0.00518:

Calculate voltage across RTD

  • T = 0 oC ; VAB = _____ millivolts
  • T = 81 oC ; VAB = _____ millivolts
  • T = -45 oC ; VAB = _____ millivolts
  • T = 320 oF ; VAB = _____ millivolts

Answer :

All answers shown here based on tabulated values for the RTD’s resistance (rather than values calculated by formula):

  • T = 0 oC ; VAB = -0.6989 millivolts
  • T = 81 oC ; VAB = 0.9568 millivolts
  • T = -45 oC ; VAB = -1.6215 millivolts
  • T = 320 oF ; VAB = 2.4831 millivolts
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Questions on DP Transmitter Wet Leg Compensating Impulse Line
Determine Effect of Each Fault for Pneumatic Force-balance System
Distillation Tower Displacer Level Instrument Check
Programmable Logic Controller (PLC) Questions and Answers – 1
Analyze the Relay Circuit and Find the Status ?
Questions on Resistive Tape Level Sensor
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Pneumatic Level Transmitter Calibration Table
Determine Calibration Range of Pneumatic Pressure Transmitter
Purge Type Level Transmitter Questions
Calculate Total Hydrostatic Pressure at Bottom of Vessel
Pneumatic Relay Questions
Practical Level Sensors Questions and Answers
Calculate the Temperature of 4 Wire RTD
Questions on Level Switches

Keep Learning

Current-to-Pressure Transducer Calibration Table

How Much Pressure indicated by Micromanometer

How Much Pressure Indicated by Micromanometer?

Pitot tube

Pitot Tube Flowmeter Calculations

Level Transmitter trend

Identify Level Control Loop Tuning Problems

DP transmitter Errors

DP Transmitter Calibration Errors

Pressure Switch Questions

Pressure Switch Questions

Siemens PLC Block Diagram

Programmable Logic Controller (PLC) Questions and Answers – 14

compressor emergency shutdown system

Solenoid Valves Questions & Answers – 2

Learn More

PLC Program with 2 Toggle Switches and 4 Motors

PLC Program with 2 Toggle Switches and 4 Motors

Spectrometers Questions and Answers

Fluorescent Spectrometer Questions & Answers

Power System Protection Quiz

Electrical Power System Protection Quiz

Instrumentation and Control Course

Free Instrumentation Course for Trainee Engineers

Dry Contact in PLC

What is a Dry Contact? – Basics of PLC Wiring

5-valve manifold

Pressure Transmitter Vent fittings

Electrical Machines Objective Questions

Electrical Machines MCQ Series 12

Comparison of Absorption Chillers and Electric (Compression) Chillers

Difference between Water Cooled Chiller and Air Cooled Chiller

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?