Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Cascade Compensation in Frequency Domain
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Cascade Compensation in Frequency Domain

Cascade Compensation in Frequency Domain

Last updated: November 27, 2021 5:40 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Cascade Compensation in Frequency Domain

1. A phase lead compensation leads to:

a) Increase in overshoot
b) Reduction in bandwidth of closed loop system
c) Reduction in rise time of closed loop system
d) Reduction in gain margin

Answer: c

Explanation: Phase lead compensation and this is similar to the high pass filter results in increase in bandwidth reduction in settling time and thus, speed of response is improved.

2. PD controller is used to compensate system. Compared to the uncompensated system, the compensated system has:

a) A higher type number
b) Reduced damping
c) Higher noise amplification
d) Large transient overshoot

Answer: c

Explanation: Proportional Derivative controller is used to increase the bandwidth and also increases the signal to noise ratio by reducing the noise and increasing the signal.

3. P+D controller:

a) Introduces offset
b) Increases bandwidth
c) Increases margin of stability
d) Reduces velocity constant

Answer: c

Explanation: Proportional Derivative controller is the controller increases margin of stability and also used to increase he bandwidth and also increases the signal to noise ratio.

4. Proportional controller:

a) Introduces offset
b) Increases bandwidth
c) Increases margin of stability
d) Reduces velocity constant

Answer: a

Explanation: Proportional controller is the controller that is block used to control the gain of the control system and introduces offset error and there is no effect on the damping factor.

5. The transfer function of a lead controller is 1+20s/1+5s. The high frequency magnitude of the lead controller to dB is ___________

a) 1
b) 2
c) 3
d) 4

Answer: d

Explanation: G(s) = Tp (1+Tds)/s^2
It is type-2 function.
The type-2 function has a finite steady state error for unit-parabolic input.

6. Controllers play the following role in control system:

a) They amplify the signals going to the actuator
b) They act on the error signal coming out of the summing junction and output a suitable to the actuator
c) They try to reduce steady state error optimizes overshoot.
d) All of the mentioned

Answer: a

Explanation: Controller amplify the signals going to the actuator and they are of many types as proportional, integral, derivative some combinational controller as combination of two controllers and combination of all the controllers.

7. The transfer function of the compensator is s+4/s+16. The maximum phase lead frequency and the corresponding phase is :

a) 6 rad/sec, 36.87°
b) 8 rad/sec, 36.87°
c) 6 rad/sec, -36.87°
d) 8 rad/sec, -36.87°

Answer: b

Explanation: Phase lead frequency is calculated when magnitude of transfer function is 1 and this is the phase cross over frequency and the phase is calculated by using the tanget formula with the transfer function.

8. Response to error is very fast for integral controller.

a) True
b) False

Answer: b

Explanation: Integral controller is used to reduce or eliminate the error of the control system and for derivative controller the damping factor is increased and speed of response also increases.

9. Consider the following statements:
1. Integral controller improves steady state response
2. By use of proportional controller, maximum peak overshoot decreases
3. Type and order of system reduces by one for derivative controller
4. Integral controller makes the system less stable in transient state due to oscillations
Select the correct answer using the codes given below:

a) 1,3 and 4
b) 1,2 and 3
c) 2.3 and 4
d) 1,2 and 4

Answer: a

Explanation: Integral controller improves steady state response and derivative controller improves the transient response, type and order of system reduces by one for derivative controller.

10. Rate mode controller is also known as ______________ controller mode.

a) Anticpatory
b) Delay
c) Integral
d) Derivative

Answer: a

Explanation: Anticipatory controller mode is also known as the rate mode controller that is used to anticipate the future value with the use of the state.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Encoder Multiple Choice Questions
Continuous Wave NMR Spectroscopy Questions & Answers
MCQ on Measurement and Instrumentation
Preliminary Considerations of Classical Design
Feedback Compensation
Top 1000 Analytical Instrumentation Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Spectral Method of Analysis Questions & Answers
Ion Transducers Questions & Answers
Top 10 Industrial safety Objective Questions
Pole Placement by State Feedback
Common Physical Nonlinearities
Relative Stability Analysis
Ammonia and Fluoride Electrode Questions & Answers
Stability of Nonlinear System – II
Optimal Control Problems – Part 2
Chromatography Questions & Answers

Keep Learning

Ion Spectrometers Questions & Answers

Instrumentation of Ion Spectroscopy

Mathematical Models of Physical Systems

Transfer Functions Objective Questions

Radiochemical Questions and Answers

Fundamentals of Radiochemical Methods Questions

Electron Spin Resonance Questions & Answers

Instrumentation of ESR Spectrometer

Chromatography Questions & Answers

Detection System of Gas Chromatography Questions and Answers

Analyzers Questions and Answers

Magnetic Wind Instruments Questions & Answers

Analyzers Questions and Answers

Dissolved Oxygen Analyzer Questions and Answers

Pollution Monitoring Instruments Questions and Answers

Hydrocarbons Questions & Answers

Discover More

Motor STAR - DELTA Working principle

Motor STAR – DELTA Starter Working Principle

Radiochemical Questions and Answers

Gamma Camera Questions & Answers

PLC Program for Star Delta Starter using Functional Block Diagram

PLC Program for Star Delta Starter using Functional Block Diagram

Digital Electronics Multiple Choice Questions

Design a flip-flop using other flip-flops Questions

AC to DC Conversion with a Commutator

DC Machines Terminology

Switch NO or NC Contact

Normally-open and Normally-closed Switch Contacts

valve trim

Valve Actuator Bench Set

Direct & reverse actions control valve

Direct Acting Control Valves & Reverse Acting Control Valves