Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Tandem Mass Spectroscopy
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Tandem Mass Spectroscopy

Tandem Mass Spectroscopy

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
6 Min Read
SHARE

Tandem Mass Spectroscopy

1. Tandem mass spectroscopy combines which of the following devices?

a) Mass spectrometer and gas-solid chromatograph
b) Mass spectrometer and gas-liquid chromatograph
c) Mass spectrometer and gas chromatograph
d) Mass spectrometer and mass spectrometer

Answer: d

Explanation: Tandem mass spectroscopy combines two mass spectrometers. It is represented as MS/MS.

2. In tandem spectroscopy, the first stage sepatation device is a mass spectrometer.

a) True
b) False

Answer: a

Explanation: In tandem spectroscopy, the first stage sepatation device is a mass spectrometer. It is represented as MS/MS.

3. Which of the following is used to separate a single mass that is characteristic of a given analyte in a mixture?

a) First mass spectrometer
b) Second mass spectrometer
c) Filter
d) Precursor

Answer: a

Explanation: First mass spectrometer is used to separate a single mass that is characteristic of a given analyte in a mixture. The single mass is known as the precursor.

4. The mass-selected ions are activated in which of the following ways that causes them to fall apart to produce product ions?

a) Collisional activation
b) Evaporational activation
c) Inert gas activation
d) Thermal activation

Answer: a

Explanation: The mass-selected ions are activated by some means that cause them to fall apart to produce product ions. They are activated by collisional activation.

5. The final MS/MS spectrum consists only of product ions from the selected precursor.

a) True
b) False

Answer: a

Explanation: The final MS/MS spectrum consists only of product ions from the selected precursor. The chemical background and other mixture components are absent.

6. In reverse-geometry mass spectrometer which of the following precedes the electric sector?

a) Nebulizer
b) Orifice
c) Magnetic sector
d) Mass spectrometer

Answer: c

Explanation: In reverse-geometry mass spectrometer magnetic sector precedes the electric sector. Early work on MS/MS was done with reverse-geometry double focussing mass spectrometer.

7. A magnetic sector alone can be used as a mass spectrometer, with roughly _____ resolution.

a) Low
b) High
c) Unit
d) Infinite

Answer: c

Explanation: A magnetic sector alone can be used as a mass spectrometer, with roughly unit resolution. Early work on MS/MS was done with reverse-geometry double focussing mass spectrometer.

8. What does the acronym ‘MIKES’ stand for?

a) Mass-analysed ion kinetic energy spectrometer
b) Mass-based induced kinetic energy spectrometer
c) Mass invasive kinetic electric spectrometer
d) Mass-analyser in kinetic energy-type spectrometer

Answer: a

Explanation: ‘MIKES’ stands for mass-analysed ion kinetic energy spectrometer. It is related to spectrometers having magnetic field sectors.

9. In MIKES experiments which of the following are measured?

a) Product ions
b) Product ion kinetic energies
c) Product ions mass to charge ratio
d) Product ions masses

Answer: b

Explanation: In MIKES experiments, mass to charge ratios are not measured. Product ion kinetic energies are measured in these experiments.

10. All ions with the same number of charges will have __________

a) Same kinetic energy
b) Different kinetic energies
c) Same mass
d) Different mass

Answer: a

Explanation: All ions with the same number of charges will have same kinetic energy. It is assumed that all ions have a single charge.

11. A tandem mass spectrometer has which of the following analysers?

a) Time of flight mass analyser
b) Magnetic deflection analyser
c) Radiofrequency analyser
d) Quadrupole analyser

Answer: a

Explanation: A tandem mass spectrometer has a filter. The filter is followed by time of flight mass analyser.

12. Which of the following filters are used in tandem spectrometer?

a) Quadrupole mass filter
b) Low energy filter
c) High energy filter
d) Time of flight mass filter

Answer: a

Explanation: A tandem mass spectrometer has a quadrupole mass filter. The filter is followed by an analyser.

13. B/E scan is which of the following scans?

a) Product ion scan
b) Precursor ion scan
c) Mass scan
d) Charge scan

Answer: a

Explanation: B/E ratio can be chosen to select ions with a given velocity. It is a product ion scan.

14. Which of the following is located in the region between two analysers?

a) Nebuliser
b) Collision cell
c) Filter
d) Vacuum chamber

Answer: b

Explanation: Collision cell is located in the region between two analysers. Low energy parent ions are mass analysed.

15. Given below is the diagram of the drift tube of a tandem quadrupole/time of flight instrument. Identify the unmarked component.

a) Nebuliser
b) Filter
c) Chopper
d) Acceleration lens

Answer: d

Explanation: The unmarked component is acceleration lens. A collision cell is located before the acceleration lens.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Fluorescent Spectrometer Questions & Answers
Robotic Control System – Part II
MCQ on Flow Measurement
Ionization of Gases Questions and Answers
IR Instrumentation Questions & Answers
Pressure Measurement Multiple Choice Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

H2S Analyzers Questions & Answers
Performance Indices
The Z-Transfer Function
Temperature and Humidity Objective Questions
Difference Equations
Control of the Effects of Disturbance Signals by Use of Feedback
Approximation of Higher-Order Systems by Lower Order
Sulphur Di-oxide Monitoring Questions & Answers

Keep Learning

Optimal Control Systems

The State Regulator Problem

Nuclear Power Plant Multiple Choice Questions

Nuclear Power Plant Multiple Choice Questions

Mathematical Models of Physical Systems

Block diagram Algebra Objective Questions

Feedback Characteristics of Control Systems

Feedback and Non-feedback Systems Objective Questions

Control Systems Stability and Algebraic Criteria

Relative Stability Analysis

Hydraulic Systems Objective Questions

Hydraulic Systems Objective Questions

Control Loops Multiple Choice Questions

Control Loop Multiple Choice Questions

Time Response Analysis

Robotic Control System – Part I

Learn More

PLC to Start or Stop 3 Machines using 1 Switch Program

PLC to Start or Stop 3 Machines using 1 Switch Program

Organization block Siemens

Tia Portal – OB30 Cyclic Interrupt Organization Block

Pressure Switch Construction

Basics of Pressure switches

Electrical Machines Questions and Answers

Electrical Machine Multiple Choice Questions

Difference between Standards and Codes

Difference between Standards, Codes, Specifications, Regulations

VFD Commissioning and Testing Procedure

VFD Commissioning and Testing Procedure (Variable Frequency Drive)

level control system

Practical Process Control System Questions & Answers – 11

What is Profinet and How to Configure in Siemens PLC

What is Profinet and How to Configure in Siemens PLC?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?