Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Ionization of Gases Questions and Answers
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Ionization of Gases Questions and Answers

Ionization of Gases Questions and Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Ionization of Gases Questions and Answers

1. Gases emit radiation under which of the following conditions which can be used for determination of gases?

a) When mixed with other gases
b) When kept at suitable temperature
c) With sufficient electrical excitation and at suitable pressures
d) When exposed to radiation

Answer: c

Explanation: Gases emit radiation with sufficient electrical excitation and at suitable pressures. Gases emit radiation in different ways. It can be in the form of spark, arc or glow discharge in different parts of radiation spectrum.

2. Which of the following measuring technique is utilized for measuring nitrogen?

a) By using a method based on gas density
b) By using paramagnetic analyzers
c) By using magnetic wind instruments
d) By using a photospectrometer where a gas sample is analysed and detected with a photocell

Answer: d

Explanation: By using a photospectrometer gas sample is analysed, for measuring nitrogen. It is then selectively filtered by using a photocell which provides an appropriate electric signal.

3. The characteristic emission of which colour, when discharge takes place in a low pressure chamber containing gas sample, will indicate the presence of nitrogen while using photospectrometer?

a) Purple
b) Blue
c) Pink
d) Green

Answer: a

Explanation: The characteristic emission of purple colour, when discharge takes place in a low pressure chamber containing gas sample, will indicate the presence of nitrogen while using photospectrometer. These are usually employed in medical applications.

4. Sample rates of nitrogen meter can be adjusted by doing which of the following?

a) By modifying the amplifier
b) With the help of the needle valve
c) By modifying the detector
d) By changing chopper frequency

Answer: b

Explanation: Sample rates of nitrogen meter can be adjusted with the help of needle valve. Modern nitrogen analyzers have digital displays.

5. Which of the following is the normal sampling rate used in nitrogen meters?

a) 13 ml/min
b) 33 ml/min
c) 3 ml/min
d) 43 ml/min

Answer: c

Explanation: The normal sampling rate used in nitrogen meters is 3 ml/min. Modern nitrogen analyzers have digital displays.

6. Nitrogen meters are calibrated for which of the following to measure nitrogen?

a) Mixture of nitrogen and air
b) Water saturated mixture of nitrogen and oxygen
c) Mixture of nitrogen and hydrogen
d) Nitrogen

Answer: b

Explanation: Nitrogen meters are calibrated for water saturated mixture of nitrogen and oxygen. Hence, this calibration cannot be used for dry gases.

7. Why is nitrogen meters generally not calibrated for dry gases while measuring nitrogen?

a) It causes error
b) Range decreases
c) Reading tend to be non-linear
d) It cannot be measured

Answer: a

Explanation: Nitrogen meters are generally not calibrated for dry gases because it will lead to error in the reading. The error will be upto 2%.

8. In which of the following ways can nitrogen be calibrated for dry gases?

a) By modifying the amplifier
b) By adjusting the needle valve
c) By modifying the detector
d) By changing chopper frequency

Answer: b

Explanation: Nitrogen can be calibrated for dry gases by adjusting the needle valve. In this way, the error will be compensated.

9. The voltage required for striking the discharge in the presence of nitrogen is 1500V.

a) True
b) False

Answer: a

Explanation: The voltage required for striking the discharge in the presence of nitrogen is 1500V. This voltage is generated using a DC-DC converter.

10. The light output from the discharge tube is interrupted by means of a rotating slotted disc.

a) True
b) False

Answer: a

Explanation: The light output from the discharge tube is interrupted by means of a rotating slotted disc. Hence, a chopped output is obtained.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Control Valves Multiple Choice Questions
Concept of Stability in Control Systems
UV Visible Spectrometers Questions and Answers
Surface Spectroscopic Techniques
Hydrocarbons Questions & Answers
Feedback Control Loop Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Time Response of Second Order Systems – I
Closed-Loop Frequency Response
H2S Analyzers Questions & Answers
Root Locus in Control Systems
Effect of Adding a Zero to a System
Assessment of Relative Stability Using Nyquist Criterion
Combination Electrode Questions & Answers
Logic Families Questions and Answers

Keep Learning

Pneumatic Systems Objective Questions

Pneumatic Systems Objective Questions

Pollution Monitoring Instruments Questions and Answers

Nitrogen Oxides Questions & Answers

Radiochemical Questions and Answers

Gamma Camera Questions & Answers

Stability in Frequency Domain

Cascade Compensation in Time Domain

Mathematical Models of Physical Systems

Differential Equations of Physical Systems & Dynamics of Robotic Mechanisms

Programmable Logic Controllers Multiple Choice Questions

Programmable Logic Controllers Multiple Choice Questions

Liapunov’s Stability Analysis

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

Transmission and Distribution Interview Questions

Measurement and Instrumentation Objective Questions – Part 3

Learn More

How Buoyant Force instruments Works

How Buoyant Force instruments Works ?

Electrical & Electronics Measurements Objective Questions

Electrical & Electronics Measurements Objective Questions – Set 1

How to Install a Rotameter

How to Install a Rotameter

Address Overlapping in Tia Portal

How to Check Address Overlapping in Tia Portal?

Instrumentation Control Systems

What is Instrumentation Control System ?

PLC Programming in Bottle Filling Process

Applications of PLC Programming in Bottle Filling Process

Analyzers Questions and Answers

Analyzers Based on Gas Density Questions & Answers

Differential Pressure Transmitter Wet Leg Compensation

Differential Pressure Transmitters Compensated Leg Systems

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?