Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Constant Flow Valve Principle
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Valves > Constant Flow Valve Principle

Constant Flow Valve Principle

Last updated: January 24, 2019 2:29 pm
Editorial Staff
Control Valves
1 Comment
Share
3 Min Read
SHARE

Constant Flow Valve keep flow rate of gases or liquids at constant value even when the supply or load pressure changes.

Contents
Applications :1. Supply Pressure Variations2. Bubbler Level Measurement3. Purging for Orifice Plate ApplicationArticles You May Like:Flow Nozzle PrincipleFlow StandardsControl Valve QuestionsGas Valve SizingNeedle Valves Applications

Constant Flow Valve

Control valve with diaphragm automatically acts following the change of pressure. They are normally delivered together with flowmeter as a “Purge set”.

Primary (Inlet) pressure variation control type and Secondary (Outlet) pressure variation control type are ready to meet all possible applications.

PRESSURE CONTROL VALVE

In the PRIMARY (INLET) PRESSURE VARIATION CONTROL TYPE, the fluid, of which inlet pressure varies, is introduced from IN to the lower chamber of the C series Constant Flow Valve.

The load pressure (Secondary pressure) is connected to the upper chamber. The differential pressure between the lower chamber and the upper chamber is always constant, thanks to the function of the Spring and the Diaphragm.

The differential pressure across the needle valve is kept always constant and the fl ow rate of the fluid is proportional only to the opening of needle valve.

Flow Control Valve

The opposite action is taken for SECONDARY (OUTLET) PRESSURE VARIATION CONTROL TYPE and the flow rate is kept also constant even when the load pressure changes.

Applications :

1. Supply Pressure Variations

Valve Supply Pressure Variations

As shown above, in case one large supply line branches into several lines and the supply pressure changes because of stoppage of some branches.

Primary Pressure Variation type Purge set will be suitable in keeping the purging volume of fl uid.

2. Bubbler Level Measurement

Bubbler Level Measurement

Liquid level in tanks is measured by the Back-pressure at the edge of purging pipe. The outlet pressure at the tank bottom changes depending on the liquid level, and constant bubbling is required.

Thus, Secondary Pressure Variation type purge set is used for this application. A DP transmitter is often connected to pressure line instead of pressure gauge for remote transmission.

3. Purging for Orifice Plate Application

Orifice Plate Purging

For the measurement of flow rate of corrosive liquids and/or liquids with solids by orifi ce plate, an equal pressure purging both to Hi and Lo pressure parts so as not to introduce liquid and/or solids into DP Pressure lead pipe. Dual mount type purge set used.

Source : tokyokeiso.co.jp

Articles You May Like:

Flow Nozzle Principle

Flow Standards

Control Valve Questions

Gas Valve Sizing

Needle Valves Applications

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
What is Lift Check Valve ?
Pilot-operated Relief Valve Principle
Control Valve Volume Booster Working Principle
Diaphragm Valves Construction, Types, Stem & Bonnet Assembly
Components of Shutdown Valve
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Gopal says:
    October 25, 2017 at 5:40 pm

    Which type of purging ( inlet Pressure or outlet pressure variation type) method used for measurement of flow and level?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Direct Lift Diaphragm Normally Open Solenoid Valve

Direct Lift Diaphragm Solenoid Valve Principle

What is an Actuator - Different Types of Actuators

What is an Actuator? – Different Types of Actuators

Malfunctioning Inlet Check Valves

Malfunctioning Inlet Check Valves caused chaos at Compressor stop/trip

Valve Interlock

Valve Interlock

cavitation-control valve trim

What is Control Valve Cavitation ?

Control Valve Positioner Working Principle

Control Valve Positioner Working Principle

Double-acting cylinder - 2

Fluid Power Systems

On-OFF Valve Animation

What is ON/OFF Valve ?

More Articles

Fixed PLC

#19 PLC Best Practices – Monitor PLC Memory Usage

Stability in Frequency Domain

Realization of Basic Compensators

Thin Client in SCADA

What is Thin Client in SCADA? – Purpose, Advantages

Measurement of Resistance Objective Questions

Measurement of Resistance Objective Questions

Heat Exchanger Differential Pressure Transmitter

Heat Exchanger Differential Pressure Transmitter

Adaptive Controller Overview

What is Adaptive Control?

Closed-tank-DP-Level-Transmitter-with-wet-leg-elevation-zero-direct-mount-Calibration

Closed tank DP Level Transmitter with wet leg elevation zero direct mount Calibration

Career Opportunities in Instrumentation Engineering

Job and Career Opportunities in Instrumentation Engineering

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?