Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Motor Inrush Current Measurements
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Motor Inrush Current Measurements

Motor Inrush Current Measurements

Last updated: November 28, 2016 4:08 am
Editorial Staff
Electrical Basics
1 Comment
Share
4 Min Read
SHARE

Why inrush current important ?

Inrush current, sometimes known as starting current or locked rotor current in motors, can be four to 10 times higher than a motor’s running current. Abnormal levels or duration of inrush current suggests a motor needs maintenance or, potentially, replacement.

Contents
Why inrush current important ?How and why to measure inrush currentWhy does this measurement matter?

Motors Inrush Currents

How and why to measure inrush current

When an electrical device is first powered on, inrush current is the surge or momentary burst of current that flows into it.

Think of a car sitting on flat pavement, parked in neutral, engine off. To get it moving without using the engine, a human would need to give it a substantial push, probably a vigorous leg drive. Once moving, though, the car’s wheels roll more cooperatively with less physical oomph required.

That initial, emphatic leg drive is the equivalent of inrush current. The subsequent, easy-rolling motion equals the steady-state current flow that occurs in a motor once its gears and rotors have been jolted out of inertia and into motion.

To measure the inrush current, technicians can use either a hard-jawed clamp meter or a flexible current probe. Only meters that offer an inrush button can measure inrush current. Here are steps for measuring it, in this case when using the Fluke 381 (see illustration above):

  1. With the device to be tested turned off, turn the meter’s dial to Clamp Meter Button or a flexible current probe also used.
  2. Center the jaw or flexible probe around the device’s live wire.
  3. Push the inrush button on the face of the meter.
  4. Switch on the device. The inrush current (spike) is displayed in the meter’s display.

Why does this measurement matter?

Newer, high-efficiency motors draw more running current than their predecessors. Knowing the value of inrush current can help a technician locate a startup problem, whether it’s in the motor or in the starting circuit. Inrush measurements are usually recorded in a preventative maintenance log for future reference.

Motor Inrush Current Graph

To provide repeatable motor inrush measurements, advanced clamp meters (such as the Fluke 370 series or the Fluke 381) use a “triggered” mode that synchronizes measurements with the starting current.

Technicians “arm” a meter by pressing its inrush button. The meter is then triggered by the inrush current. Once triggered, this inrush function takes approximately 400 samples over a 100-millisecond period and calculates the actual starting current.

Inrush current may cause a meter’s display to show a value that is higher than the rating of the circuit breaker, yet the breaker does not trip. Why so?

Inrush current can be 4 to 10 times greater than the normal running current, depending on the type of motor. So if a motor’s running current is eight amperes and its circuit breaker is rated for 20 amperes, how is it possible that a clamp meter could display a measurement of 40 amps?

The reason the breaker or overload unit do not trip is because both devices work on a time-vs.-current curve. This curve (see chart) indicates how much current passes through the breaker, and for what length of time, without opening the circuit.

Motor inrush current Problems

Article Source: Fluke

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Basic Electrical Engineering Questions & Answers
Types of Motor Loads – Constant & Variable Torque, Horsepower
Basics of Electricity Rates
Difference between KW and KVA
Advantages of Star and Delta Systems
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Dulan sanjeewa says:
    December 7, 2016 at 3:18 am

    Help ful document.and also best brand for measurement.fluke.i am also using.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Three phase induction motor nameplate

How to Size a Cable for Industrial AC Motors?

Benefits of SIMOCODE over Intelligent MCC

Benefits of SIMOCODE over Intelligent MCC

Characteristics of Protective Relay

What is a Protective Relay? Principle, Advantages, Applications

Totally Enclosed Fan Cooled (TEFC) Motor

Totally Enclosed Fan Cooled (TEFC) Motors Rampant Winding Burnouts

RDOL starter

What are DOL and RDOL starters? Advantages, Disadvantages

running two single-phase induction motors sequentially

Control Two Motors in Sequence after Time Delay – Circuit, Operation

Electrical Motor Model number and serial number

How to Read the Nameplate of a Motor?

Fuse in a Electrical Circuit

Advantages & Disadvantages of Fuse in a Electrical Circuit

More Articles

Loop Current Step Response (LCSR) Test for RTD

Response Time Test of RTD and Thermocouple

multi-hole-restriction-orifice-plate

Basics of Restriction Orifice (RO) – Types, Applications, Standards

Electromagnetic Flow Meters Working Principle

Electronics Mini Projects

300+ Best Electronics Mini Projects

Twisted Pair Cable Noise Supression

Why We use Shielded Cable and Twisted Pair Cables ?

Importance of Fire & Gas Detection System

Importance of Fire & Gas Detection System

Double-acting cylinder - 2

Fluid Power Systems

What is NEST loading in DCS

What is Nest Loading? – DCS and PLC Control Systems

Follow US