An Excellent Answer by Bently Nevada Employee:

As a 20-year Bently Nevada employee, and as someone responsible for answering such questions over the years within our company as well as externally, allow me to explain the rather interesting circumstances behind the use of negative voltages (-24 vdc) for powering eddy current vibration oscillator/demodulator devices. I will then proceed to explain the operating principles behind the eddy current proximity probe and how it converts physical gap between the probe and its target into a voltage.

First, the question of negative voltage. The short answer is that When Don Bently worked on making solid-state versions of the eddy-current measurement system (it was actually originally designed in the 1930s by GE engineers using vacuum tubes), he had a choice between using N-P-N transistors or P-N-P transistors. At the time, transistors were quite expensive, so he chose the least expensive of the two: P-N-P (apparently, PNP transistors they were less expensive to manufacture 50 years ago than their NPN counterparts).

Because the circuits used PNP transistors, a negative bias voltage was required rather than a positive bias voltage. Don chose -18V. This was later changed to -24V to allow more linear range from the transducer.

At that time, the industrial instrumentation community had not yet standardized on +24 vdc, and by the time they did, there were so many Bently Nevada eddy current vibration sensors installed that changing to +24V rather than -24V was not greeting with enthusiasm by users. Hence, it has remained -24V to this day.

This was not a deliberate effort to “be different” or “non-conformist” on the part of Bently Nevada. It was quite literally based on which components were the least expensive when the technology was originally introduced 50-plus years ago.

Now, the question of how an eddy-current proximity probe works:

An eddy-current probe works by passing an alternating current through a coil of wire and measuring the coil’s impedance. This impedance changes when the probe is brought near an electrically conductive material and the impedance change is proportional to the physical gap between the coil and the conductive target. The sensing electronics in turn convert this impedance change to a voltage, providing an electrical output directly proportional to physical gap which is directly proportional to vibration.

Also Read: Vibration Sensors Principles & Types

You've successfully subscribed !

View Comments

Share

Recent Articles

Immersion Heaters in Lube Oil Consoles
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

57 mins ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

3 weeks ago
  • PLC Tutorials

From Boolean Algebra to PLC Logic

In this article, a simple example will teach you the conversion from Boolean algebra to…

1 month ago
  • PLC Tutorials

PLC Cooking Timer Example for Kitchen Automation

In this article, you will learn the PLC cooking timer example for kitchen automation using…

3 weeks ago
  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

3 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

3 weeks ago