Question 1

The acronym PLC stands for:

(A) Pressure Load Control
(B) Programmable Logic Controller
(C) Pneumatic Logic Capstan
(D) PID Loop Controller
(E) Pressure Loss Chamber

Answer : B

Question 2

Ladder logic programming consists primarily of:

(A) Virtual relay contacts and coils
(B) Logic gate symbols with connecting lines
(C) Function blocks with connecting lines
(D) Text-based code
(E) Hieroglyphics

Answer : A

Question 3

In a PLC, the scan time refers to the amount of time in which …..

(A) the technician enters the program
(B) timers and counters are indexed by
(C) one “rung” of ladder logic takes to complete
(D) the entire program takes to execute
(E) transmitted data communications must finish

Answer : D

Question 4

Identify the problem in this motor control PLC program:

Motor PLC Program

(A) Coil
(B) Start contact
(C) Seal-in contact
(D) Stop contact
(E) Power source

Answer : C

Question 5

The Boolean representation of this PLC program is:

(A) ABC + D
(B) C + (A + B)D
(C) C + D(A + B)
(D) ABC + BD
(E) C(AB + D)

Answer : E

Question 6

The difference between online and offline PLC programming is . . .

(A) whether the PLC is running or stopped
(B) whether the programming PC has internet connectivity
(C) the type of programming cable used
(D) where the edited program resides
(E) the type of programmer used

Answer : D

Question 7

In PLC programming, a retentive function is one that:

(A) Defaults to the “on” state
(B) Comes last in the program
(C) Defaults to the “off” state
(D) Cannot be edited or deleted
(E) Is not reset after a power cycle

Answer : E

Question 8

What is the largest integer number that a PLC counter function can reach if it uses a 16 bit register?

(A) 32,768
(B) 65,535
(C) 65,536
(D) 65,537
(E) 32,767

Answer : B

Question 9

An OR function implemented in ladder logic uses:

(A) Normally-closed contacts in series
(B) Normally-open contacts in series
(C) A single normally-closed contact
(D) Normally-open contacts in parallel
(E) Normally-closed contacts in parallel

Answer : D

Question 10

A good application for a timed interrupt in a PLC program would be:

(A) A communications function block
(B) A PID function block
(C) A math function block
(D) A motor start/stop rung
(E) A “watchdog” timer

Answer : B

Credits : by Tony R. Kuphaldt

You've successfully subscribed !

View Comments

Share

Recent Articles

  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

3 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

3 weeks ago
  • PLC Tutorials

From Boolean Algebra to PLC Logic

In this article, a simple example will teach you the conversion from Boolean algebra to…

1 month ago
  • PLC Tutorials

PLC Cooking Timer Example for Kitchen Automation

In this article, you will learn the PLC cooking timer example for kitchen automation using…

3 weeks ago
  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

3 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

3 weeks ago