Multiple Choice Questions

Parameter Optimization

Parameter Optimization

1. A conditionally stable system exhibits poor stability at :

a) Low frequencies
b) Reduced values of open loop gain
c) Increased values of open loop gain
d) High frequencies

Answer: b

Explanation: A conditionally stable system is the system which is stable only for certain values of K and exhibits poor stability at the reduced values of open loop gain.

2. The type 0 system has ______ at the origin.

a) No pole
b) Net pole
c) Simple pole
d) Two poles

Answer: a

Explanation: The type of the system is defined as the property of the system which has pole at the origin.

3. The type 1 system has ______ at the origin.

a) No pole
b) Net pole
c) Simple pole
d) Two poles

Answer: c

Explanation: The type of the system is defined as the pole at the zero and type 1 is defined as the 1 pole at the origin.

4. The type 2 system has at the origin.

a) No net pole
b) Net pole
c) Simple pole
d) Two poles

Answer: d

Explanation: Type of the system is defined as the number of pole at origin and type 2 is the 2 poles at the origin.

5. The position and velocity errors of a type-2 system are :

a) Constant, constant
b) Constant, infinity
c) Zero, constant
d) Zero, zero

Answer: c

Explanation: The position and velocity error of the type 2 system is zero and a constant value as for type 2 system velocity error is finite while acceleration error is infinite.

6. Velocity error constant of a system is measured when the input to the system is unit _______ function.

a) Parabolic
b) Ramp
c) Impulse
d) Step

Answer: b

Explanation: Velocity error constant of a system is measured when the input to the system is unit ramp function then only velocity error is finite but error due to other inputs are not defined.

7. In case of type-1 system steady state acceleration is :

a) Unity
b) Infinity
c) Zero
d) 10

Answer: b

Explanation: In case of type-1 system steady state acceleration is infinity as for the type less than 3 acceleration is not defined it is infinity.

8. If a step function is applied to the input of a system and the output remains below a certain level for all the time, the system is :

a) Not necessarily stable
b) Stable
c) Unstable
d) Always unstable

Answer: a

Explanation: If the input is bounded and output is also bounded then the system is always stable and step input is bounded and the output is always under certain li its then the system is stable.

9. Which of the following is the best method for determining the stability and transient response?

a) Root locus
b) Bode plot
c) Nyquist plot
d) None of the mentioned

Answer: a

Explanation: Root locus is the best method for determining stability of the transient response as it gives the exact pole zero location and also their effect on the response.

10. Phase margin of a system is used to specify which of the following?

a) Frequency response
b) Absolute stability
c) Relative
d) Conditional stability

Answer: b

Explanation: Phase margin of the system can be used for determining the absolute stability of the system.

You've successfully subscribed !
Share

Recent Articles

VFD Simulator Download – Free Yaskawa V1000 Software
  • PLC Tutorials

VFD Simulator Download – Free Yaskawa V1000 Software

VFD simulator download: Master the online tool from the Yaskawa V1000 & programming software for…

2 days ago
  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

5 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

5 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

6 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

3 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

5 days ago