PLC Tutorials

LIFO Instruction in PLC

LIFO is a special programming instruction that can be used in the applications that require to store the sequence of data in order and unload it.

Now we are gonna see how are loading and unloading done in LIFO.

LIFO Instruction in PLC

Yes! LIFO should be used in a pair. There should be an instruction to load and there should be an instruction to unload.

The following are the block parameters in LIFO load instruction,

Source: Here is where one should give an address where the values to be loaded are present.

LIFO: Here is where one should specify the address where the values have to be loaded. This address seems weird right with an ‘#’ in the front. When we use an ‘#’ symbol in the front, It is called an array of addresses. Obviously there will be a sequence of values present to be loaded arrays are capable of storing many values right? So why we gave ‘#’ in the front should make sense now.

Control: Here is where one should specify the control address. In the Rockwell PLC programming environment, there is a separate address for the control with R6:0 as starting one. So when the LIFO load is done loading the values the R6:0 address gives us a true bit.

Length: Here is where we have to specify the length of the array so that the array of address prepares them for loading the values.

Position: Here is where we have to give the index number of an array from where the loading has to start. I’ll leave it to 0 so the loading starts from the 0th index.

The following are the block parameters in LIFO unload instruction,

LIFO: Here is where one has to give the address where the values to be unloaded are present. So obviously both the load and unload has the same address in here.

Dest: Here is where one has to give the address where the values have to be unloaded.

Control, Length, and Position carry the same explanation from the LIFO load.

Now we’re going to the run time to see how the loading and unloading happens,

Now we are on the run time and when the input to LFL is made to turn on the value on N7:0 gets loaded to the array address #B3:0. B3:0 is a binary address to view the value as decimal change the radix to decimal.

Refer to the below figure for the first loaded value.

You can also see the number of lengths we specified is 4 and the Binary data file shows us from 0 to 3.

Here is the next loaded value.

Since we didn’t change the number in the source the same number will get loaded to the destination address.

You can see that the position is increasing in the LFL and LFU as the value is getting loaded. So the value is getting loaded from left to right the starting position is 0 and the ending is 3.

Also, notice that the value gets loaded for each false to the true transition of the rung. Refer to the below figure.

So now we have completed loading the values now the Position is at 10 and the done bit goes to the true state.

You can also notice from the figure that the Done bit is turned on after completely loading the values.

Now we are going to look at the unloading of the data,

Now I made the LFU rung true you can notice that the done bit goes OFF again.

Also, notice that the value which got loaded last comes out first. So the expansion of LIFO is called Last in First Out. The one which came last unloads first.

Likewise, whenever the rung makes false to true transition each value unloads in a manner that which came last goes out. So the last value which comes out should be 30.

You can also notice from the figure that the empty bit goes up when the values on the LIFO address become empty.

An example of a real-time application where LIFO is used might be tracking parts through an assembly line where parts are represented by values that have a part number and assembly code.

Author: Abishek D

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

You've successfully subscribed !
Share

Recent Articles

  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

2 weeks ago
  • PLC Tutorials

Batch Mixing with PLC Ladder Logic Program

In this example, we will learn batch mixing with PLC ladder logic program using timer…

1 week ago
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

2 weeks ago
  • PLC Tutorials

PLC Programming Example with Pushbutton and Motor

In this article, you will learn the PLC programming example with pushbutton and motor control…

3 weeks ago
  • PLC Tutorials

Boolean Logic to PLC Programming

This article teaches how to convert Boolean logic to PLC programming ladder logic with the…

1 month ago
  • PLC Tutorials

PLC Programming Example on Timers Function Block

In this article, you will learn the PLC programming example on timers function block using…

3 weeks ago