Practical Questions

Determine the functions of Pressure Switches ?

Determine the functions of all pressure switches and relays in this steam boiler monitoring circuit, and what each of their designations mean:

pressure switches relay circuit

Also, explain the significance of the switch symbols: normally open versus normally closed. The time- delay relay (TD1) is especially important here!

Finally, add a “Lamp Test” pushbutton switch to this circuit which will force all lamps to energize when pressed, in order to test the proper operation of the lamps without waiting for an abnormal process condition to occur.

Explain the following questions :

  1. Why do you suppose a time-delay relay is used in this particular control application?
  2. Is the boiler shutdown solenoid energize-to-trip or de-energize-to-trip? Explain how we can tell from an examination of the schematic.
  3. Identify where in this circuit you could install a PSHHH (pressure switch high-high-high) that would trip the boiler immediately.
  4. Identify a circuit fault that would cause the boiler to needlessly shut down (a “safe” fault).
  5. Identify a circuit fault that would cause the boiler to not be able to shut down when it needs to (a “dangerous” fault).

Answer

  • PSL = Pressure Switch, Low
  • PSH = Pressure Switch, High
  • PSHH = Pressure Switch, High-High

Both warning lamps should be off when the steam pressure is between 80 and 200 PSI. The boiler will automatically shut down when the shutdown solenoid de-energizes, and this will happen if the steam pressure exceeds 220 PSI for at least 10 seconds.

The difference between a “normally open” process switch and a “normally closed” process switch is vitally important for technicians to understand. The “normal” condition referred to in each label does not mean the condition that is typical for the process. Rather, it refers to a condition where the switch is subjected to minimum stimulus. In other words, the “normal” condition for each switch is:

  • Temperature switch = cold
  • Pressure switch = low or no pressure
  • Level switch = empty vessel
  • Flow switch = low or no flow

Share Your Answer / Comments

Credits : by Tony R. Kuphaldt – under CC BY 1.0

You've successfully subscribed !
Share

Recent Articles

  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

4 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

1 day ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

3 weeks ago
  • PLC Tutorials

From Boolean Algebra to PLC Logic

In this article, a simple example will teach you the conversion from Boolean algebra to…

1 month ago
  • PLC Tutorials

PLC Cooking Timer Example for Kitchen Automation

In this article, you will learn the PLC cooking timer example for kitchen automation using…

3 weeks ago
  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

3 weeks ago