Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Components of Mass Spectrometer Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Components of Mass Spectrometer Questions & Answers

Components of Mass Spectrometer Questions & Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Components of Mass Spectrometer Questions & Answers

1. Which of the following is not a component of mass spectrometer?

a) Inlet system
b) Sweep generator
c) Ion transducer
d) Mass analyser

Answer: b

Explanation: Sweep generator is not a component of mass spectrometer. It is a component of NMR spectrometer.

2. Which of the following can be introduced into the ionization chamber directly?

a) Solid samples with low vapour pressure
b) Solid samples with high vapour pressure
c) Liquid samples with low density
d) Liquid samples with high density

Answer: a

Explanation: Solid samples with low vapour pressure can be introduced into the ionization chamber directly.

3. Inlet system is also known as which of the following?

a) Initial system
b) Sample reservoir
c) Sample handling system
d) Element injection system

Answer: c

Explanation: Inlet system introduces the sample into the ion source. Hence, it is called sample handling system.

4. Which of the following is normally done to convert the sample into gaseous state?

a) Sample is pressurized
b) Chemical reactions are made to occur
c) Sample is heated
d) Sample is cooled

Answer: c

Explanation: The sample must always be in gaseous state. Hence, liquid sample must be heated before introducing them into the ionization chamber.

5. Which of the following probes are used for the introduction of the sample?

a) Silica
b) Quartz
c) Graphite
d) Silver

Answer: a

Explanation: Solid samples with low vapour pressure are introduced into the entrance of the chamber. They are introduced using silica or platinum probe.

6. Which of the following is not a type of ionisation?

a) Field ionisation
b) Spontaneous ionisation
c) Spark ionisation
d) Chemical ionisation

Answer: b

Explanation: Spontaneous ionisation is not a type of ionisation. In mass spectrometer, ionisation is brought about by thermal or electrical energy.

7. Mass analyser is similar to which of the following in optical spectrometer?

a) Source
b) Monochromator
c) Detector
d) Sample

Answer: b

Explanation: Mass analyser is similar to monochromator in optical spectrometer. It separates ions according to their mass/charge ratio.

8. Which of the following is not one of the types of mass analyser?

a) Magnetic sector analyser
b) Frequency sweep analyser
c) Double focussing spectrometer
d) Time of flight analyser

Answer: b

Explanation: Frequency sweep analyser is not a type of mass analyser. There are many devices available for mass analysis.

9. Which of the following is not a type of ion detector used in mass spectrometers?

a) Electron multiplier
b) Flame emission detector
c) Faraday cup collector
d) Photographic plates

Answer: b

Explanation: Flame emission detector is not a type of ion detector used in mass spectrometers. Ion detectors produce current on the output side when there are ions on the input side.

10. Which of the following is used to inject liquid samples?

a) Hypodermic needle
b) Glass bulb
c) Capillary tube
d) Curvette

Answer: a

Explanation: Liquid samples are injected through hypodermic needles. It is vaporized at low pressure.

11. Under which of the following temperatures is the ionisation chamber maintained?

a) 100oC
b) 200oC
c) 300oC
d) 400oC

Answer: b

Explanation: The ionisation chamber is maintained at 200oC. It is also maintained at low pressure.

12. Given below is the block diagram of mass spectrometer. Identify the unmarked component.

a) Inlet system
b) Ionisation chamber
c) Vacuum system
d) Ion transducer

Answer: d

Explanation: The unmarked component is ion transducer. It will give current at the output at its output side when ions are present on the input side.

13. Which of the following is not a characteristic of nebulizers that are commonly used?

a) Low cost
b) Low uptake rate
c) High efficiency
d) High uptake rate

Answer: d

Explanation: Commonly used nebulizers have low uptake rate. They also have low cost and high efficiency.

14. In glow discharge ion source, the sample is atomised by which of the following process?

a) Evaporation
b) Sputtering
c) Heating
d) Annealing

Answer: b

Explanation: In glow discharge ion source, the sample is atomised by the process of sputtering. It not only atomizes the sample but also provides means by which these atoms are ionized

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Closed-Loop Frequency Response
Magnetic Wind Instruments Questions & Answers
Measurement and Instrumentation Objective Questions – Part 1
Z-transform Analysis of Sampled-Data Control Systems
Special Designs of Ion Selective Electrodes Questions & Answers
Neural Networks
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Biosensors Questions & Answers
IR Instrumentation Questions & Answers
Robotic Control System – Part II
Process Pressure Measurement Objective Questions
Nyquist Stability Criterion
Mathematical Preliminaries
Types of NMR Spectrometers Questions & Answers
Control Loop Multiple Choice Questions

Keep Learning

Chromatography Questions & Answers

Chromatography Questions & Answers

Time Response Analysis

Performance Indices

Root Locus Concepts Objective Questions

Construction of Root Loci

Feedback Characteristics of Control Systems

Controller Components – Part 2 Objective Questions

pH Analyzers Questions and Answers

pH Meters Questions & Answers

Feedback Characteristics of Control Systems

Linear Approximation of the Non-Linear System MCQ

Radiochemical Questions and Answers

Fundamentals of Radiochemical Methods Questions

Digital Control Systems

Difference Equations

Learn More

Turbidity Sensor Calibration Procedure

Turbidity Sensor Calibration Procedure

PLC Water Project

Smart Spray System using Wecon PLC

cat5e plenum cable

cat5e Plenum Cable History, Advantages and Disadvantages

simple motor start-stop circuit

Liquid Level Switch Control Logic

Flow Measurement Objective Questions

Flow Measurement Objective Questions

Analog Input Card Resolution Effects on Accuracy

PLC Analog Input Card Resolution Effects on Accuracy

Automatic Car Washing Process using PLC Ladder Diagram

Automatic Car Washing using PLC

Instrumentation Thread

Thread Sealant Types and Selection for Instrumentation Applications

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?