Jatin Katrodiya

Jatin has 11 years of experience in the field of instrumentation and control (Engineering and commissioning domain). He has hands-on experience on DCS, ESD, F&G system, MMS, Specialized Instrumentation, Valves & Analysers. He is excellent in cross discipline coordination and interfacing (P&ID review, HAZOP, SIL Study, 3D model review etc). He is skilled in Instrument sizing e.g. Control Valve, Flow meter, PSV; UPS load calculations, Intrinsic safety validation, SIL verification etc. He is well versed with international code and standards.
Orifice Sizing Guidelines and Thumb Rules with Flowchart
  • Instrumentation Design

Orifice Sizing Guidelines and Thumb Rules with Flowchart

Here we shared the brief details of orifice sizing guidelines and a simple flowchart with basic thumb rules during the…

1 year ago
  • Control Valves

Control Valve in Nutshell – Valve Design and Selection Factors

In this article, you will learn the important factors for control valve selection and process design parameters in a nutshell.

2 years ago
  • Instrumentation Design

How to Fill up Instrument Datasheet? – Pressure Gauge Specifications & Standards

In this article, you will learn how to full up instrument datasheet, pressure gauge specifications and their standards.

1 year ago
  • Instrumentation Design

Instruments Tapping Points – Common versus Individual

In this article, we are going to discuss when to use common tapping points and individual tapping points for the…

2 years ago
  • Instrumentation Design

Role of an Instrumentation Design Engineer for Beginners

Here we discussed the role and job profile of a control and instrumentation (C&I) design engineer during the project engineering.

6 months ago
  • Safety Instrumented System (SIS)

Basic Terms used in SIL Verification

This article elaborates basic definition and use of HFT, SFF, and PFDavg terms which are widely used during the SIL…

6 months ago
  • Control Systems

PLC or DCS Control System Spares

PLC or DCS Control system spares are consumable & commissioning spares, installed, 2 years operational and mandatory spares.

2 years ago
  • PLC Tutorials

What is Marshalling Cabinet?

This marshalling cabinet function is to interface the incoming field cable (which is normally a multipair cable) and the I/O…

6 months ago
  • Control Systems

What is WHCP?

Wellhead control panel (WHCP) is used to provide hydraulic supply to the wellhead valves, choke valves, HIPPS, and fusible plug…

2 years ago
  • Control Systems

Anti Surge Controller Working Principle

Anti Surge Controller will open and close the anti surge control valve as necessary to control the compressor within operating…

2 years ago