Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Why Circuit Breakers Don’t Protect People?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Why Circuit Breakers Don’t Protect People?

Why Circuit Breakers Don’t Protect People?

Exploring the limitations of circuit breakers: why they're essential for electrical circuits but do not protect against electric shocks.

Last updated: September 27, 2024 5:29 am
Viral Nagda
Electrical Basics
No Comments
Share
5 Min Read
SHARE

We know how circuit breakers play a very important role in electrical circuits. It is virtually impossible to design any electrical drawing without a circuit breaker. They are a switching device used to pass current and trips in case of a fault. This protects the electrical devices from any further damage. But, these circuit breakers usually don’t protect people from an electric shock. In this post, we will see why circuit breakers do not protect people.

Contents
What is a circuit breaker?Circuit breakers and Electric shock

What is a circuit breaker?

What is a circuit breaker

First of all, let us understand what a circuit breaker is. As the name suggests, a circuit breaker is a device which is used to break the electrical supply flowing in a path in case of a fault. It is a switch type device which is hand-operated. When open, the current will not flow through the breaker. When closed, the current will flow through the breaker.

Now, when it is closed and if any fault is sensed by the breaker during operation, it will open immediately and trip the circuit. It can be again asked to operate by either pressing the reset button in it or by manually closing the switch again, depending on the type of breaker. Some of the usual faults that can occur in a circuit are earth leakage, short circuit, over-current, damaged circuit breaker, faulty wiring, or overloading.

Practically, a circuit breaker is chosen as 25% more than the overall flowing current in the circuit. For example, if it is chosen in a path which will carry 50A, the required rating of the breaker should be 50*1.25 as 62.5A. So, any current value above 62.5 will trip the breaker.

Circuit breakers and Electric shock

Why Circuit Breakers Don't Protect People?

Now, let us understand why circuit breakers usually do not protect people from electric shock. A circuit breaker is designed to carry current like a normal switch. In normal conditions, the voltage or current will also be normal under-rated values. But still, the current is flowing.

Now, if a person accidentally touches the wire or any live component, a live conducting path will flow through his body to the ground, making a connection. This will burn and heat up the internal body parts of the person and may even cause death. The circuit breaker has no role in this, because it knows that the current value is under rated values and not under tripping conditions. So, it will remain closed.

In this case, there are also chances that a short-circuit or overloading can happen due to a person getting in contact and consuming electricity. This will take at least 2 seconds for the breaker to trip (the actual time depends on the type of circuit breaker and varies from case to case) . But, these 2 seconds are enough for the person to get himself damaged.

But here, let us consider an important part where this concept can be challenged by some special circuit breakers like ground fault circuit interrupter (GFCI) and arc fault circuit interrupter (AFCI). Even if there is a slight leakage between live and ground (which can also happen due to a person getting in contact), these breakers will trip immediately. Basically, both these devices measure current balance between incoming and outgoing, and any imbalance makes the breaker trip immediately. It will surely take small microseconds to detect the fault; but it is better than 2 seconds from further damaging the human body parts.

Circuit breakers can protect your electrical panels from fire hazards, overcurrent, overloading, faulty wiring, or broken electrical devices. It will cut off the power and make your circuit isolated from fault. But, it will not protect people from getting an electric shock, unless some special circuit breakers mentioned above are used. So, this concept entirely depends on how you choose the circuit breaker and what are its trip characteristics. 

Read Next:

  • Automatic Circuit Recloser
  • De-energized Electrical Circuits
  • How to Locate Faults in Cables?
  • Variable Air Volume Controller
  • Why is HV Testing important?

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Differences between Watts and Volt Amps
Why is the Humming Sound Produced in Transformer?
Stepper Motor Working Principle
Preventive Maintenance of Variable Frequency Drive (VFD)
Difference Between Circuit Breaker and Disconnector
Electrical Energy Management System and SCADA in Power System
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Contactor – Basics, Wiring, Connection with PLC
Motor STAR – DELTA Starter Working Principle
Why is Phase Failure Relay Required in LV Panels?
Polarization Index (PI) Test and DA Test
Applications of Variable Frequency Drive (VFD)
Motor Forward and Reverse Direction Control using Limit Switches
What is Transformer Bushing? Working Principle
Technical Specification for Uninterrupted Power Supply (UPS) System

Keep Learning

Control Methods in Servo Motor Drives

Various Control Methods in Servo Motor Drives

Why Are Charcoal and Salt Added to an Earthing Pit

Why Are Charcoal and Salt Added to an Earthing Pit?

Types of Batteries

Cells and Batteries – Types, Applications, Explanation

What is Air Circuit Breaker

What is an Air Circuit Breaker? Working Principle & Applications

Residual Current Circuit Breaker (RCCB)

Residual Current Circuit Breaker (RCCB)

VFD Braking

DC Injection Braking in VFD

Typical Switchyard Layout

Electrical Substation – Busbar Arrangements and Layouts

Difference Between Wattmeter and Energy Meter

Difference Between Wattmeter and Energy Meter

Learn More

Cut-outs between Platforms or Grating for Field Instruments

Cut-outs between Platforms or Grating for Field Instruments

Pneumatic-Level-Transmitter-Value-Struck

Pneumatic Level Transmitter Value Struck?

Types of Calibration

Types of Calibration

Pulse Generation using Timer in Siemens PLC

Pulse Generation using Timer in Siemens PLC

What is VLAN?

Difference Between Subnet and VLAN

General Streams in Electronics Engineering

General Streams in Electronics Engineering for Students

Pause the Timer PLC Ladder Logic

Pause the Timer PLC Ladder Logic

Ohm Meter Circuit

Ohm Meter

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?