Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Difference between PVC, XLPE, and Insulated Cables
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Difference between PVC, XLPE, and Insulated Cables

Difference between PVC, XLPE, and Insulated Cables

In this article, you will learn the difference between PVC, XLPE, and Insulated Cables, and their features and characteristics.

Last updated: March 24, 2023 3:46 pm
Shiv Kumar
Electrical Basics
No Comments
Share
7 Min Read
SHARE

In this article, you will learn the difference between PVC, XLPE, and Insulated Cables, and their features and characteristics.

Contents
What is a PVC Cable?What is Cross Linked Polyethylene XLPE Cable?Characteristics of XLPE CableFeatures of XLPE CableDifferences between PVC and XLPE Insulated CableWhat is the Colour of the XLPE cable?How to identify the cable for PVC or XLPE?Which Cable is better either XLPE insulated cables or PVC insulated cables?

What is a PVC Cable?

A Poly Vinyl Chloride (PVC) cable is an electrical cable coated with PVC that provides superior insulation and protection to the main wire. They don’t have chemical properties and can thus be widely used in a variety of chemical industries. They are waterproof in nature & they are suitable for both high and low temperatures.

PVC-insulated cables offer the following benefits:

  • They are extremely adaptable in a variety of weather conditions.
  • They have a low relative permeability, which means they rarely allow liquids or gases to pass through.
  • They are less expensive than many other types of electric cables.
  • Suitable for the standard configuration of power stations to rated AC voltages of 450/750V or less.
  • PVC has a wide range of common plastics in the world, and it is very wide.
  • Polyvinyl chloride is poorly stabilized.
  • The softening point is 176 degrees Fahrenheit.
  • Decomposition begins at 266 fairness.
  • It emits toxic smog that is harmful to the human body when burned.

What is Cross Linked Polyethylene XLPE Cable?

XLPE stands for cross-linked polyethylene. It is named because polyethylene is insulated with it.

They also provide several advantages such as

  • They can be used in extreme weather conditions, such as hot summers and cold winters.
  • They are resistant to cracking, abrasion, and scratching, and they limit radiation effects.
  • They can be used in high-voltage applications.
  • They are waterproof and thus can be used in moist or wet environments.
  • These cables are appropriate for distribution networks, industrial devices, and other parts requiring high-capacity electrical applications.
  • It was used to secure it to an AC 50Hz power transmission line, with a rated voltage of 6kV 35kV.
  • Its primary function is to communicate power.
Difference between PVC, XLPE, and Insulated Cables

Characteristics of XLPE Cable

  • Simple Structure
  • Lightweight
  • Better Hot Resistance
  • Strong Load Capacity
  • Not Easy to Melt
  • Chemical Corrosion
  • High Mechanical Strength

Features of XLPE Cable

Heat Resistance:

  • XLPE is extremely heat resistant.
  • It does not decompose or carbonize, has a long working temperature of 194 degrees Fahrenheit, and can provide heat for up to 40 years.

Insulation Properties:  XLPE retains its original good insulation properties while increasing insulation resistance.

Mechanical Properties:

  • New chemical bonds were developed among the macromolecules.
  • Some properties such as hardness, stiffness, wear resistance, and impact resistance are now improved.
  • Filling the gaps left by PEs vulnerable to environmental stresses and cracks.

Chemical Resistance:

  • XLPE has excellent acid and oil resistance properties.
  • Combustion products such as water and carbon dioxide are less harmful to the environment and meet modern fire safety standards.

Differences between PVC and XLPE Insulated Cable

When deciding the appropriate cable type for the required industrial project conflicts arise between installing PVC insulated cable and XLPE cable.

We must select a type of low voltage of 0.6/1kv cable for our industrial project. Generally, we go for PVC insulated cable and XLPE insulated cable.

But we must know the differences between these two cables which are popularly used. XLPE cable is similar to the improved version of Poly Vinyl Chloride cable.

XLPE insulated cable has some benefits that PVC doesn’t

  1. Lighter Weight.
  2. Small Diameter
  3. Convenient Installation
  4. Simple Accessories
  5. Strong Load Capacity
  6. High Heat Resistance
  7. No Chemical Corrosion

The maximum working temperature of:

  • PVC insulated Cable is 70 Degrees Centigrade,
  • XLPE insulated Cable is 90 Degrees Centigrade.

Maximum short temperature below 5 seconds:

  • PVC insulated Cable is 160 Degrees Centigrade,
  • XLPE insulated Cable is 250 Degrees Centigrade.

Service life:  XLPE insulated cable has better service life compared to PVC insulated cable.

Cost:  The price of XLPE insulated cable is higher whereas PVC insulated cable is cheaper.

WaterProof Performance in Application Environment:  PVC insulated cable exhibits better Water Proof Performance compared to XLPE insulated cable.

Environment Protection:

When compared to PVC insulated Cable, XLPE insulated Cable is more environmentally friendly since XLPE doesn’t contain chlorine that liberates toxic gases on burning.

Life span with good Performance:

  • XLPE insulated Cable spans more than PVC insulated Cable in the long run.
  • Since the price of XLPE is a little higher.
  • Considering all factors like environmental protection, service life, and safety issues XLPE insulated cable marks good.
FactorPVC CableXLPE Cable
Electric LoadSuitable for Regular LoadsSuitable for Greater Loads
InstallationEasy to InstallHard to Install
Heat ResistanceAverageGood
Chemical ResistanceGoodVery Good
Max Operating Temp.70 Degrees C90 degrees C
Short Circuit Temp.160 Degrees C250 degrees C
Min Operating Temp-15°C-400 C
HealthToxicNeutral
ToughnessGoodPoor Compare to PVC
Cost SavingCostlier than XLPECheaper than PVC

What is the Colour of the XLPE cable?

Generally, XLPE cables are constructed with large dielectric grade cross-linked polyethylene for insulation.

Red, Yellow, Blue, and a reduced neutral core in Black are the three half-core colors.

How to identify the cable for PVC or XLPE?

Observe the cable clearly for legend marking, these markings are Australian standard codes used for installation.

  • If it represents V-90 then it is PVC insulated cable.
  • If it represents X-90 then it is XLPE insulated cable.

Which Cable is better either XLPE insulated cables or PVC insulated cables?

When compared to PVC, XLPE has higher tensile strength, elongation, and impact resistance.

This cross-linking process also improves the material’s resistance to oil and chemicals at high temperatures, making XLPE a popular choice for LSZH Flame Retardant or Fire Resistant cables.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Introduction to Protective Systems
How to Connect a 3 Phase Motor in Star and Delta Connections?
What is an Intelligent Motor Control Center? – IMCC
Why is Phase Failure Relay Required in LV Panels?
Difference Between Open Circuit and Close Circuit
What is a Power Transformer? – Components and Types
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What are HP and LP Switches in HVAC?
What is a Ground Rod?
Advantages of Star and Delta Systems
Difference Between AIS and GIS Panels
Motor STAR – DELTA Starter Working Principle
Difference Between MPCB and MCCB
Why is the Humming Sound Produced in Transformer?
Difference Between Wattmeter and Energy Meter

Keep Learning

How to Identify Phase, Earth, and Neutral Wires_

How to Identify Phase, Earth, and Neutral Wires?

Semiconductor Fuse

What is a Semiconductor Fuse?

What is Transformer Bushing

What is Transformer Bushing? Working Principle

Top 100 Power Systems Projects

Top 100 Power Systems Projects – Electrical Engineering

Difference between UPS and Stabilizer

Difference between UPS and Stabilizer?

Single Line Diagram (SLD) Example

Electrical Drawings

What is Power Cable

What is Power Cable? Types of Power Cables

Floating Neutral - Electrical Engineering Basics

What is Floating Neutral? – Electrical Engineering Basics

Learn More

Thermocouples Green Rot Effect

Thermocouples Green Rot Effect

Left-Hand Rule for Generators

Starting of DC Motors

Automatic Car Door Simulation

Automatic Door Operation PLC Programming and Simulation

Flow Measurement Questions and Answers

80+ Flow Measurement Interview Questions and Answers

0-20 mA Analog Signal to Measurement Converter Tool

0-20 mA Analog Signal to Measurement Converter Tool

Left-hand Rule for Current Carrying Conductors

Magnetism

Lamp Counter Logic

Function Block (FB) for Motor Control Logic

Electrical Machines Objective Questions

Electrical Machines Objective Questions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?