Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Types of Motor Loads – Constant & Variable Torque, Horsepower
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Types of Motor Loads – Constant & Variable Torque, Horsepower

Types of Motor Loads – Constant & Variable Torque, Horsepower

In this article, we will learn the various types of motor loads such as constant & variable torque, and horsepower loads.

Last updated: October 12, 2022 12:36 pm
Viral Nagda
Electrical Basics
No Comments
Share
5 Min Read
SHARE

In this article, we will learn the various types of motor loads such as constant & variable torque, and horsepower loads.

Contents
Types of Motor LoadsConstant Torque LoadsVariable Torque LoadsConstant Horsepower Loads

Types of Motor Loads

The type of load that a motor drives is one of the most important application considerations when applying any type of AC drive.

For some types of loads, the application considerations may be minimal. For other types of loads, an extensive review may be required.

Generally, loads can be grouped into three different categories:

  1. Constant Torque Loads – conveyors, hoists, drill presses, extruders, positive displacement pumps (torque of these pumps may be reduced at low speeds).
  2. Variable Torque Loads – fans, blower, propellers, centrifugal pumps.
  3. Constant Horsepower Loads – grinders, turret lathes, coil winders.

Constant Torque Loads

Constant torque loads are where applications call for the same amount of driving torque throughout the entire operating speed range.

In other words, as the speed changes, the load torque remains the same.

Constant Torque Load of Electrical Motor

The chart shows speed on the bottom and torque on the left. The torque remains the same as the speed changes. Horsepower is affected and varies proportionately with speed.

Constant torque applications include everything that is not variable torque applications. In fact, almost everything but centrifugal fans and pumps are constant torque.

Variable Torque Loads

As was just mentioned, there are only two kinds of variable torque loads: centrifugal pumps and fans.

With a variable torque load, the loading is a function of the speed. Variable torque loads generally require low torque at low speeds and higher torque at higher speeds.

Fans and pumps are designed to make air or water flow. As the rate of flow increases, the water or air has a greater change in speed put into it by the fan or pump, increasing its inertia.

In addition to the inertia change, increased flow means increased friction from the pipes or ducts. An increase in friction requires more force (or torque) to make the air or water flow at that rate.

The effects that reduced speed control has on a variable torque fan or pump are summarized by a set of rules known as the Affinity Laws.

The basic interpretation of these laws is quite simple:

  1. The flow produced by the device is proportional to the motor speed.
  2. The pressure produced by the device is proportional to the motor speed squared.
  3. The horsepower required by the device is proportional to the motor speed cubed.
Variable Torque Motor Load

The cube law (third item) load is at the heart of energy savings. The change in speed is equal to the horsepower cubed.

For example, you might expect a 50% change in speed would produce a 50% change in volume and would require 50% of the horsepower.

Luckily for us, this 50% change in speed must be cubed, representing only 12.5% of the horsepower required to run it at 100% speed.

The reduction of horsepower means that it costs less to run the motor. When these savings are applied over yearly hours of operation, significant savings accumulate.

This table will help show these relationships:

% Speed% Torque% HP
100100100
908172.9
806451.2
704934.3
603621.6
502512.5

Constant Horsepower Loads

A constant horsepower load is when the motor torque required is above the motor’s base speed (60 Hz). With a constant horsepower type of load, the torque loading is a function of the changing physical dimensions of the load.

These types of applications would include grinders, turret lathes, and winding reels. Constant horsepower loads require high torque at low speeds and low torque at high speeds.

While the torque and speed changes, the horsepower remains constant.

Motor Constant Horsepower Loads

For example, an empty reel winding a coil will require the least amount of torque, initially, and will be accelerated to the highest speed. As the coil builds up on the reel, the torque required will increase and the speed will be decreased.

In this way, we understand the various types of loads that can be connected to a motor.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Why V/f Ratio is kept Constant in VFD?
Motor VFD Drive features
Difference between Current Transformer and Potential Transformer
Things to Know When Measuring Current
What are HP and LP Switches in HVAC?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Flame Cables

Difference Between Flame Resistant and Flame Retardant Cables

Difference Between Open Circuit and Close Circuit

Difference Between Open Circuit and Close Circuit

What is an Electrical Drive

What is an Electrical Drive? Types, Advantages, Disadvantages

Armoured cable

What is an Armoured Cable? Classification of Cables

Top 10 Common Mistakes on Electrical Systems

Top 10 Common Mistakes on Electrical Systems

Electrical Cabinet Air Conditioner

Electrical Cabinet Air Conditioner – Enclosure Cooling, Maintenance

Types of Tripping Protection in MCCB

Types of Tripping Protection in MCCB

Difference Between Alternator and Generator

Difference Between Alternator and Generator?

More Articles

Surge Protection for the Fieldbus System

Digital Electronics Multiple Choice Questions

D Flip Flop Objective Questions

Micro Sensors Objective Questions

Micro Sensors Objective Questions

Radar and Ultrasonic Level Transmitter Problems Troubleshooting

Radar and Ultrasonic Level Transmitter Practical Problems Troubleshooting

Time Delay Fuse

What is a Time Delay Fuse? – Principles and Advantages

What is a Lightning Arrester? How does it work?

PLC NOR Logic

Logic Gates in PLC Ladder Logic

Control Systems Questions & Answers

Control Systems Objective Questions & Answers – Set 1

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account