Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Difference Between MCB and RCBO
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Difference Between MCB and RCBO

Difference Between MCB and RCBO

Many types of electrical circuit breakers are used in industries. In this post, we will learn the difference between MCB and RCBO.

Last updated: September 28, 2022 3:44 pm
Viral Nagda
Electrical Basics
No Comments
Share
4 Min Read
SHARE

In this post, we will learn the difference between MCB and RCBO.

Circuit breakers are an essential part of the electrical circuit. It is a device that is used as a protective switch for passing electrical current with tripping conditions checked. When it detects a trip condition, the breaker opens its contact and isolates the input and output voltage from contacting each other.

Many types of circuit breakers are used in a circuit; but in this post, we will focus on two of the most used ones – MCB and RCBO.

Difference between MCB and RCBO

Difference between MCB and RCBO

We will see the difference between both of them in this post. Many get confused in its naming convention and consider both of them as equal. But, there are considerable differences between both of them.

  • MCB stands for Miniature Circuit Breaker and RCBO stands for Residual Current Breaker with Overcurrent.
  • MCB is used to protect against overload and short-circuit. But, RCBO is used to protect against earth leakage fault current with over-current also. Many do not know the exact meaning of earth leakage fault; let us understand it first. In a normal circuit, line and neutral currents will always be equal and balanced. But, whenever there is an earth leakage, as the leakage current flows through the earth, there will be an imbalance in both these currents as the line current will be higher than the neutral current. This difference in current is called residual current.
  • The major difference that separates both circuit breakers is that RCBO has the additional protection of earth leakage current. Basically, it majorly uses microcontrollers and it can also be said as a combination of MCB and RCCB. That is why; it is more useful than MCB; because MCB does not provide protection against the earth-leakage current.
  • MCB is selected based on the load, maximum short-circuit current it can interrupt, and trip curve. RCBO too is selected on the basis of these three things; but apart from that, it also considers maximum leakage current.
  • Cost-wise, RCBO is costlier than MCB.
  • MCB is used to protect lighting circuits, air conditioners, and other home appliances; but RCBO is used mainly to interrupt power to water heaters, power sockets, etc. where there is the possibility of electric shocks to humans.
  • MCB does not provide protection against electric shocks to humans, but RCBO provides protection against electric shocks. This is because the role of RCBO is primarily to detect earth leakage and trip the circuit when detected. Earth leakage is dangerous for the human body. Typically, the human body can withstand a shock of 30mA. After this, it can lead to paralysis or even death for weaker human hearts. And, earth leakage current typically starts from 10mA and can go beyond 30mA.
  • The breaking capacity of RCBO is much higher than MCB (typically up to 10kA).
  • Some RCBO’s also have indicators on them to show any earth fault trip. This feature is very helpful as it quickly aides the engineer in troubleshooting faults. Such a feature is not available in MCB’s.

These are the differences between MCB and RCBO. It must be up to the electrical engineer to decide what to choose if he knows the basic requirements and functions.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Types of Motor Enclosures
What is a Substation? Purpose of an Electrical Substation
Types of Earth Leakage Circuit Breaker
What is SMPS? – Types of SMPS
Types of Tripping Protection in MCCB
Corona Discharge in Power Transmission Lines
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Why is White Powder Used in Electrical Cables?
Testing of Thermal Protection Relay for Motors
Difference Between HV and LV Cables
Differences between Watts and Volt Amps
What is a Megger? Principle, Advantages, Disadvantages, Applications
What is Transformer Bushing? Working Principle
What is a Power Transformer? – Components and Types
Dahlander Motor Control Circuit and Power Circuit

Keep Learning

Gas-Insulated Transmission Line

What is Gas-Insulated Transmission Line? Principle Advantages

What are HP and LP Switches in HVAC

What are HP and LP Switches in HVAC?

Electrical Maintenance Engineer's Biggest Enemy

Electrical Components Overheating – Causes, Troubles, Prevent

Pros and Cons of Soft Starter

Pros and Cons of Soft Starter

Instrument Cable

Difference Between Power Cable and Instrument Cable

Motor Disconnector Switch

What is a Motor Disconnector Switch? – Purpose, Principle, Factors

Most Asked Questions on Servo Motor

Most Asked Questions on Servo Motor (Answers)

Arc Protective Clothing

What is Arc Protective Clothing? – Importance, Features, Materials

Learn More

Instrumentation Engineering Materials Test

Instrumentation Engineering Materials Test

Differential Pressure Switch Working Principle

Displacer Type Density Transmitter

Displacer Type Density Transmitter Question

Pressure Safety Valves Functional Testing

Pressure Safety Valves Functional Testing

Diagnosing the Electric Motor Circuit

Diagnosing Electric Motor Circuit

Boiler Drum Level Control Systems

Boiler Drum Level Control Systems

FDA Process Validation

Why You Need FDA Process Validation and How to Do It Right ?

Interview Questions on Battery Testing

Interview Questions on Battery Testing

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?