Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: How Much Pressure Indicated by Micromanometer?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > How Much Pressure Indicated by Micromanometer?

How Much Pressure Indicated by Micromanometer?

Last updated: June 2, 2020 1:34 pm
Editorial Staff
Practical Questions
No Comments
Share
3 Min Read
SHARE

A simple way to make a micromanometer (an extremely sensitive manometer) is to connect two large-diameter vertical tubes by a small-diameter, transparent tube with an air bubble in it. The air bubble becomes the marker for reading pressure along a scale:

Micromanometer

How Much Pressure indicated by Micromanometer

If both of the large vertical tubes are 2.5 inches in diameter, and the transparent, horizontal tube is 0.25 inches in diameter, how much differential pressure will be indicated by 1 inch of horizontal bubble displacement? Assume the use of water for the manometer liquid.

Answer:

1 inch of bubble motion represents 0.02 inches of water column pressure (differential), or 2/100 ”W.C., applied across this micromanometer.

To solve for this pressure, first determine the amount of liquid volume that would have to be displaced to move the bubble 1 inch. Since the bubble resides in a tube 0.25 inches in diameter, the volume for 1 inch of bubble motion is:

(1 inch)[π(0.25 inch / 2)2] = 0.04909 in3

This is a very small amount of liquid volume! The water levels in the larger (2.5 inch diameter) tubes will not have to change much to accommodate this tiny amount of displacement. Dividing the displaced fluid volume by the area of the vertical tubes will tell us how far the water levels must change in each of the vertical tubes:

(0.04909 in3) / [π(2.5 inch / 2)2] = 0.01 inch

So, a vertical liquid column height change of only 0.01 inch will cause a horizontal bubble displacement of 1 inch. Since there will be 0.01 inch of movement in each vertical tube, the combined total vertical displacement is twice this figure, or 0.02 inches of water column.

A much simpler way to solve this problem is to recognize that the vertical tube areas are 100 times as great as the horizontal tube (2.5 inches is ten times as large as 0.25 inches, and area is proportional to diameter squared), so 1 inch of horizontal fluid displacement is proportional to 1/100 inch of vertical fluid displacement.

Once again, since each vertical tube experiences 0.01 inch of vertical water level displacement, the total water column shift is 0.02 inches.

Read Next:

  • Level Objective Questions
  • Tube and tube fittings
  • Volumetric Flow Calculations
  • Inclined Water Manometer?
  • DP Transmitter Elevation

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Stilling Well in Interface Level Measurement System
Calculate Amount of Weight Indicated by the Scale
Find Thermocouple Ouput Voltage
Solenoid Valves Questions & Answers – 4
Define Normal Status of a Process Switch ?
Identify High Flow Alarm and Low Flow Alarm?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Analyze the Relay Circuit and Find the Status ?
Displacer Level Transmitter Questions
What is the Purpose of Bourdon Tube Gauge Spiral Spring?
DP Transmitter Block and Bleed Valves
What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?
Transmitter Calibration Range of a Vessel Level
Diagnosing Electric Motor Circuit
Calculate Differential Pressure Sensed by Level Transmitter

Keep Learning

Alternative Vessel Level Indication

What is the Simple Alternative Vessel Level Indication?

Level Transmitter trend

Identify Level Control Loop Tuning Problems

Allen-Bradley PLC Circuit

Programmable Logic Controller (PLC) Questions and Answers – 12

pressure transmitter calibration setup

Questions on Pressure Transmitter Calibration Setup

Motor ladder Logic

Draw a ladder logic circuit for the electric motor of an air compressor ?

Double Block and Bleed Valves Opening or Closing Sequence

Double Block and Bleed Valves Opening or Closing Sequence

Allen-Bradley MicroLogix controller

Programmable Logic Controller (PLC) Questions and Answers – 15

Steam Eductor Question

Steam Eductor Question

Learn More

pressure gauge snubber

Pressure Gauge Snubbers

PLC Compressor Control Ladder Logic

PLC Compressor Control Ladder Logic

Electrical Machines Questions and Answers

Power Flow Through an Inductive Impedance Questions

RC Triggering

SCR Triggering Methods

Resistive Transducers Objective Questions

Resistive Transducers Objective Questions

wash column temperature control

Pneumatic Instrumentation

different types of threads based on 4 standards

Different Types of Threads based on 4 Standards

Skin Type Thermocouple

Skin Type Thermocouple

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?