Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Top 10 Facts about HART Technology
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Communication > Top 10 Facts about HART Technology

Top 10 Facts about HART Technology

Last updated: December 22, 2018 1:24 am
Editorial Staff
Communication Instrumentation Design
1 Comment
Share
5 Min Read
SHARE

What You Thought You Knew But Didn’t

1: HART is Useful Only for Device Set-up, Commissioning, and Periodic Maintenance

FACT: HART can offer many more valuable benefits. It can be used as a part of a plant network to improve plant operations… signal verification, device status, secondary variables and other operational data… 24 hours a day, 7 days a week.

2: The Only Way to Communicate with a HART Device is by Using a Handheld Communicator

FACT: There are many systems and I/O devices that can communicate with HART devices without the use of a handheld communicator. The handheld can even be a Palm or other personal portable device. PC-based configurators can also be used to communicate with HART devices via a HART compatible modem.

3: Only 2-wire Transmitter Type Field Devices Communicate Using HART

FACT: There is a wide range of HART-capable devices in all process measurement and control product categories including valve positioners and actuators (pneumatic and electric). There are many 4-wire or “powered” devices that offer HART as a communication option such as magnetic flowmeters, level devices, analyzers (liquid and gas), control devices (control systems, PLCs, multiplexers) and many others. Practically all categories of measurement and control devices use HART communication today.

4: HART is a Proprietary Protocol Used By Only a Few Companies

FACT: HART is the globally recognized de facto standard for automation communication using “smart” instruments. The HART Communication Foundation is an international organization with more than 50% of its 130-plus members based outside North America – 45% European and 12% Asian.

5: HART Devices Cannot Communicate When The 4-20mA Signal Is Being Used For Control

FACT: HART Protocol allows the simultaneous communication of the continuous 4-20mA as well as a second digital communication path resting on top of the analog signal but not interfering. The digital information is communicated via the field proven Frequency Shift Key (FSK) technology that superimposes a digital signal on top of the analog signal.

6: A Device Description (DD) Must Be Used To Communicate With A HART Device

FACT: A DD is an optional element of the HART communication technology and is not required to communicate with a HART device. DDs are mostly used for device set-up are not required for routine device communication.

7: HART Communication Is Not Fast Enough To Be Useful In Process Control Applications

FACT: With HART, the analog 4-20mA signals are there full time to address the needs of fast changing or critical process measurements. Data to support multivariable measurements, remote diagnostics, and device status can be accessed digitally while the analog signal is being used for control.

8: HART Is An Interim Technology Until The All Digital Fieldbus Arrives

FACT: Newer technologies do not always automatically replace existing ones. Industry consultants predict that HART will easily be supported and remain a significant communication technology for the next 15 to 20 years. HART technology continues to be updated to address additional market needs as evidence by the recent HART 6 specification approval.

9: HART Offers Little Value For Plant Control Systems And Enterprise Level Networks

FACT: Accessing the data in HART devices on a “full-time” routine basis increases performance, integrity, and reliability of plant control and enterprise level systems. Getting digital data direct from the device avoids the filtering that may occur in acquiring this information through intermediate systems. Process variables are provided in engineering units. Status indicators provide information on the quality of data and health of the device.

10: Everybody Understands HART Communication And Fully Uses Its Capability

FACT: Since HART technology has been around for many years, most people feel that they know all that there is to know about it. The fact is the vast majority of HART applications utilize only a fraction of the full capability of HART. HART technology can be applied full-time easily and cost effectively allowing many applications to become much more valuable to the enterprise.

Also Read: Interview Questions on HART

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Level Instruments General Specifications
Basics of Cable Shields
Foundation Fieldbus Signal Conversion Formula
What is Timeout in Communication Protocols?
How Modbus Communication works
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • tabrez says:
    April 18, 2016 at 4:03 pm

    we can use 250 ohms resistance in hart communicator online with dcs

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

WirelessHART Device Terminals

WirelessHART Network Gateway Device

Industrial Automation Protocols

Industrial Automation Protocols

Axial Diaphragm Seal Connection

Difference between Axial and Radial Diaphragm Seal Connection?

Level Sensor Pressure vessel mounting

Level Instruments Design Rules

Ethernet Questions and Answers

Ethernet Communication Interview Questions & Answers

Switches, Repeaters, Bridges, Routers, Firewalls

Purpose of Gateways, Bridges & Routers in Networking

control-valve-actuators

Control Valve Selection Tips

OPC-OLE-for-Process-Control

What is OPC ?

More Articles

Industrial motor control using PLC instruction list programming

PLC Instruction List for Motor Reverse and Forward Direction

Automatic Liquid Mixing Application

PLC Program for Automatic Liquid Mixing Application

PLC attendance system design

Attendance System PLC Program using CX-Programmer

Types of Fire Detectors

Types of Fire Detectors

Ladder Logic Vs. Other Programming Languages - PLC Basics

Ladder Logic Vs. Other Programming Languages – PLC Basics

4 way solenoid valve root cause

Safety Liquid Ammonia Disconnect threatens NH3 Vapor Spill

P&ID Guidelines for Pumps

P&ID Guidelines for Pumps

Vehicle Electrical Batteries upgrade

Upgrading the Electrical System in an Automobile