Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Top 10 Facts about HART Technology
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Communication > Top 10 Facts about HART Technology

Top 10 Facts about HART Technology

Last updated: December 22, 2018 1:24 am
Editorial Staff
Communication Instrumentation Design
1 Comment
Share
5 Min Read
SHARE

What You Thought You Knew But Didn’t

1: HART is Useful Only for Device Set-up, Commissioning, and Periodic Maintenance

FACT: HART can offer many more valuable benefits. It can be used as a part of a plant network to improve plant operations… signal verification, device status, secondary variables and other operational data… 24 hours a day, 7 days a week.

2: The Only Way to Communicate with a HART Device is by Using a Handheld Communicator

FACT: There are many systems and I/O devices that can communicate with HART devices without the use of a handheld communicator. The handheld can even be a Palm or other personal portable device. PC-based configurators can also be used to communicate with HART devices via a HART compatible modem.

3: Only 2-wire Transmitter Type Field Devices Communicate Using HART

FACT: There is a wide range of HART-capable devices in all process measurement and control product categories including valve positioners and actuators (pneumatic and electric). There are many 4-wire or “powered” devices that offer HART as a communication option such as magnetic flowmeters, level devices, analyzers (liquid and gas), control devices (control systems, PLCs, multiplexers) and many others. Practically all categories of measurement and control devices use HART communication today.

4: HART is a Proprietary Protocol Used By Only a Few Companies

FACT: HART is the globally recognized de facto standard for automation communication using “smart” instruments. The HART Communication Foundation is an international organization with more than 50% of its 130-plus members based outside North America – 45% European and 12% Asian.

5: HART Devices Cannot Communicate When The 4-20mA Signal Is Being Used For Control

FACT: HART Protocol allows the simultaneous communication of the continuous 4-20mA as well as a second digital communication path resting on top of the analog signal but not interfering. The digital information is communicated via the field proven Frequency Shift Key (FSK) technology that superimposes a digital signal on top of the analog signal.

6: A Device Description (DD) Must Be Used To Communicate With A HART Device

FACT: A DD is an optional element of the HART communication technology and is not required to communicate with a HART device. DDs are mostly used for device set-up are not required for routine device communication.

7: HART Communication Is Not Fast Enough To Be Useful In Process Control Applications

FACT: With HART, the analog 4-20mA signals are there full time to address the needs of fast changing or critical process measurements. Data to support multivariable measurements, remote diagnostics, and device status can be accessed digitally while the analog signal is being used for control.

8: HART Is An Interim Technology Until The All Digital Fieldbus Arrives

FACT: Newer technologies do not always automatically replace existing ones. Industry consultants predict that HART will easily be supported and remain a significant communication technology for the next 15 to 20 years. HART technology continues to be updated to address additional market needs as evidence by the recent HART 6 specification approval.

9: HART Offers Little Value For Plant Control Systems And Enterprise Level Networks

FACT: Accessing the data in HART devices on a “full-time” routine basis increases performance, integrity, and reliability of plant control and enterprise level systems. Getting digital data direct from the device avoids the filtering that may occur in acquiring this information through intermediate systems. Process variables are provided in engineering units. Status indicators provide information on the quality of data and health of the device.

10: Everybody Understands HART Communication And Fully Uses Its Capability

FACT: Since HART technology has been around for many years, most people feel that they know all that there is to know about it. The fact is the vast majority of HART applications utilize only a fraction of the full capability of HART. HART technology can be applied full-time easily and cost effectively allowing many applications to become much more valuable to the enterprise.

Also Read: Interview Questions on HART

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

PLC Digital Signals Wiring Techniques
Technical Specification for Uninterrupted Power Supply (UPS) System
Diaphragm Seal Material Selection
Fieldbus Cables
What is HART- IP ?
Immersion Heaters in Lube Oil Consoles
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • tabrez says:
    April 18, 2016 at 4:03 pm

    we can use 250 ohms resistance in hart communicator online with dcs

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Orifice Flow Meters: Detailed Specifications
Why is an Instrument Process Datasheet Required?
Basic Terms used in SIL Verification
Latest ProfiBus Questions and Answers
Basics of Thermistors, Thermocouples and RTD’s
Voting Concept in Package Safety System
Instrumentation and Control Project Packages – Detail Engineering
What is a Network ?

Keep Learning

Instrumentation and Process Control Project Inputs

Instrumentation and Process Teams Interactions in Design Engineering Companies

PLC TB Wiring

Electrical Signal and Control Wiring

Manchester encoding

Foundation Fieldbus Electrical Parameters

Gas Detectors Location Installation

Gas Detectors Installation Techniques

Network topologies

Different Types of Network Topologies

What is a Fieldbus?

% of Reading vs. % of Full Scale Accuracy

% of Reading vs. % of Full Scale Accuracy

Fieldbus Segment Design

Foundation Fieldbus Segment Design

Learn More

Instrumentation and Control Engineer Subject

Competency Factors of Instrument & Control Engineer (Design Engineering)

Level Gauge Working Animation

Sight Glass Level Measurement Principle

Quiz on Manual Motor Starters

100 Electromagnetic Motor Starters Multiple Choice Questions

Quiz Questions for Instrumentation and Control Professionals

200 Quiz Questions for Instrumentation and Control Professionals

Sorting PLC Program Simulation

Sorting & Distribution Line PLC Programming – Advanced Logic

diaphragm-pressure-gauge

Diaphragm Pressure Sensors

Features of Scada Which are Must in an IoT System

Features of Scada Which are Must in an IoT System

Radiochemical Questions and Answers

Fundamentals of Radiochemical Methods Questions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?