Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Practical Process Control System Questions & Answers – 3
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Practical Process Control System Questions & Answers – 3

Practical Process Control System Questions & Answers – 3

Last updated: June 22, 2018 11:13 am
Editorial Staff
Practical Questions
No Comments
Share
3 Min Read
SHARE

Consider this control system, set up to maintain the temperature of a chemical reactor vessel at a constant (“setpoint”) value. The reactor’s source of heat is a steam “jacket” where hot steam is admitted through a motor-operated (M) control valve (TV) according to the temperature inside the reactor sensed by the temperature transmitter (TT):

Practical Control Systems Questions & Answers

You arrive at work one day to find the operator very upset. The last batch of product emptied from the reactor was out of spec, and the temperature displayed by the indicating controller (TIC) shows it to be 197 oF. The setpoint is set at 175 oF, and the controller is in the automatic mode as it should be.

Your first step is to look at the indication on the controller showing the output signal going to the motoractuated steam valve (TV). This output signal display (the “manipulated variable”) shows 0 %, which means “valve fully closed.”

Next, you decide to check the temperature shown at the temperature indicator (TI) located near the temperature transmitter (TT) on the reactor. There, you see a temperature indication of 195 oF.

From this information, determine what is the most likely source of the problem, and explain how you made that determination.

More Questions :

  1. Why is it important for us to know that the controller is in automatic mode? Would it make a difference if it were in manual mode instead?
  2. Explain why the first two diagnostic steps were to check the controller’s output display, then to check the TI on the reactor. What do each of these checks tell us about the nature of the problem?
  3. Suppose a fellow instrument technician were to suggest to you that the problem in this system could be a controller configured for the wrong action (e.g. direct action instead of reverse action). Do you think this is a plausible explanation for the symptoms reported here? Why or why not?

Share Your Answers via Comments

More Questions & Answers :
Practical Process Control System Questions & Answers – 1
Practical Process Control System Questions & Answers – 2
Practical Process Control System Questions & Answers – 3
Practical Process Control System Questions & Answers – 4
Practical Process Control System Questions & Answers – 5
Practical Process Control System Questions & Answers – 6
Practical Process Control System Questions & Answers – 7
Practical Process Control System Questions & Answers – 8
Practical Process Control System Questions & Answers – 9
Practical Process Control System Questions & Answers – 10
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What Affect the Pressure Measurement Accuracy of a Manometer?
Purge Type Level Transmitter Questions
Practical Process Control System Questions & Answers – 12
Sketch a Ladder Diagram for PLC to Energize the Lamp
Questions on Radar LT Loop Diagram
Re-calibrate the Foxboro DP Pneumatic Transmitter
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Three-valve Manifold on Remote Seal DP Transmitter
Question on Remote Seal with Capillary Tubing Transmitter
Fisher model 546 I/P transducer
Smart DP Transmitter Flow Meter Calculations
Troubleshoot Allen Bradley PLC Logic
Process Control Loop Testing
Double Block and Bleed Valves Opening or Closing Sequence
Upgrading the Electrical System in an Automobile

Keep Learning

pressure transmitter calibration setup

Why Pressure Vessel Connected to Tubing System?

Differential Pressure Measurement across Baghouse

Differential Pressure Measurement across Baghouse

Smart DP transmitter Formula

DP Transmitter Error Calculations

steadily pour a liquid into vertical tube

Vertical Tube Liquid Level Equilibrium

Steam flow to the heat exchanger

Analytical Process Control Question

Tank uses 3 Pressure Transmitters to Measure Level & Density

Tank uses 3 Pressure Transmitters to Measure Level & Density

Questions on Resistive Tape Level Sensor

Questions on Resistive Tape Level Sensor

Determine the statuses of all lamps and relay coils in the circuit

Determine the Status of Lamps and Relays in the Circuit ?

Learn More

Force Balance Pressure Transmitters

Pneumatic Pressure Transmitters Principle

surface-mounted water pump

Surface-mounted Water Pump

Troubleshooting Pump Control Circuit

Troubleshooting Pump Control Circuit

Pressure Safety Valves Functional Testing

Pressure Safety Valves Functional Testing

McLeod Gauge Working Principle

McLeod Gauge Working Principle

Analyzer Sample Conditioning

Sodium Analyzer Problems and Troubleshooting Steps

Photodiode as Variable Resistance Device

Photodiode as Variable Resistance Device

Essential Safety Tips for Glass Workers

Essential Safety Tips for Glass Workers

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?