Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > State Variables & Linear Discrete Time Systems

State Variables & Linear Discrete Time Systems

Last updated: November 27, 2021 5:40 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

State Variables & Linear Discrete Time Systems

1. Which of the following can be used as a tacho generator in control systems?

a) Microsyn
b) DC servomotor
c) AC servomotor
d) Magnetic Amplifier

Answer: c

Explanation: Tacho-generator in the control system is used to manage the speed and convert the speed into measurable terms and AC servomotor can be used as Tacho generator in control systems.

2. Consider the function F (s)= 5/s(s2+3s+2), the initial value of f(t) is:

a) 5
b) 5/2
c) 5/3
d) 0

Answer: d

Explanation: For initial value theorem in which time is at t =0 and for the frequency which is the inverse of time, the value of s is replaced with infinity and hence the value obtained is 0.

3. An electric motor is developing 10KW at a speed of 900rpm. The torque available at the shaft is:

a) 106 N-m
b) 66 N-m
c) 1600 N-m
d) 90 N-m

Answer: a

Explanation: The formula of the Torque =9.544*Power/speed in rpm and unit is N-m and by this the value of the torque can be calculated.

4. Assertion (A): Many of the linear control system transfer function do not have poles or zeroes in the right half s-plane.
Reason (R): These are called minimum phase transfer function.

a) Both A and R are true and R is correct explanation of A
b) Both A and R are true and R is not correct Explanation of A
c) A is True and R is false
d) A is False and R is true

Answer: a

Explanation: For minimum phase systems the poles and zeroes must be on the left side of the s-plane and for the systems which have zeroes on the right half of the s plane are called non-minimum phase systems.

5. The tacho meter has sensitivity of 5V/1000rpm. The gain constant of the tacho meter is:

a) 0.48V/rad/sec
b) 0.048V/rad/sec
c) 4.8V/rad/sec
d) 48V/rad/sec

Answer: b

Explanation: Gain constant = 5*60/2p*1000(V/rad/sec)
0.048 V/rad/sec.

6. The closed loop transfer function of a unity negative feedback system is 100/(s2+8s+100). Its open loop transfer function is:

a) 100/s+8
b) 1/s2+8s
c) 100/s2-8s
d) 100/s2+8s

Answer: d

Explanation: For unity feedback system the closed loop transfer function is: G/1+GH and the open loop transfer function can be calculated by balancing the value of G.

7. The impulse response of a linear LTI system is given as g (t) = e(-t)The transfer function of the system is equal to:

a) 1/s
b) 1/s(s+1)
c) 1/(s+1)
d) s/(s+1)

Answer: c

Explanation: Impulse response is just the Laplace transform of the transfer function and the response is just the Laplace transform of the forward path block.

8. In a closed loop for which the output is the speed of the motor, the output rate control can be used to:

a) Limit the speed of the motor
b) Limit the torque output of the motor
c) Reduce the damping of the system
d) Limit the acceleration of the motor

Answer: a

Explanation: For motor to be the closed loop system the output of the system is the speed of the motor and output rate can be to limit the speed of the motor.

9. In servo-system, the device used for derivative feedback is known as:

a) Synchro
b) Servomotor
c) Potentiometer
d) Tacho generator

Answer: d

Explanation: Tacho generator provides the derivative feedback when used in a servo system and it controls the speed of the servo-system by providing the value of the speed as feedback.

10. The transfer function of any stable system which has no zeros or poles in the right half of the s-plane is said to be:

a) Minimum phase transfer function
b) Non-minimum phase transfer function
c) Minimum phase frequency response function
d) Minimum gain transfer function

Answer: a

Explanation: For a minimum phase system all the poles and zeroes of a transfer function must lie on the left of the imaginary axis and these type of the systems if causal are always stable.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Top 100 Control Systems Objective Questions & Answers
X-Ray Diffractometers Questions & Answers
Gamma Camera Questions & Answers
State Variable Analysis – Part I
Construction of Phase -Trajectories
The Infinite Time Regulator Problem
Share This Article
Facebook Copy Link Print
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

State Models for Linear Continuous Time Systems
Magnetic Wind Instruments Questions & Answers
Feedback Compensation
Analyzers Based on Gas Density Questions & Answers
Gas Solid Chromatography Questions & Answers
Bode Plots MCQ
Direct Method & Constructing of Liapunov for the Linear & Non-Linear System
Level Measurement Multiple Choice Questions
Control Loop Multiple Choice Questions
Electron Probe Microanalyser Questions & Answers

Keep Learning

Pollution Monitoring Instruments Questions and Answers

Nitrogen Oxides Questions & Answers

pH Analyzers Questions and Answers

pH Meters Questions & Answers

Split-Range, Auto-Selector Ratio, And Cascade Systems

Split-Range, Auto-Selector, Ratio & Cascade Systems

Bipolar Junction Transistors Questions & Answers

Measurement and Instrumentation Objective Questions – Part 1

Pollution Monitoring Instruments Questions and Answers

Carbon Monoxide Questions & Answers

Stability in Frequency Domain

Assessment of Relative Stability Using Nyquist Criterion

Instrumentation Diagrams Multiple Choice Questions

Instrumentation Diagrams Multiple Choice Questions

Digital Control Systems

Signal Reconstruction

Discover More

Stilling wells

Stilling Wells for Level Measurement

Automatic exhaust fan control

XG5000 PLC Programming for Automatic Exhaust Fan

Control of Double-acting Pneumatic Cylinder

Ladder Logic for Control of Double-acting Pneumatic Cylinder

Pressure Measurement Objective Questions

Pressure Measurement Objective Questions

Micro Sensors Objective Questions

Micro Sensors Objective Questions

Top 100 Instrumentation Engineering Questions & Answers

Top 100 Instrumentation Engineering Questions & Answers

Power Electronics Objective Questions

Single-Phase Full Wave AC-DC Converter Quiz

Questions and Answers on Motors and Generators

100+ Questions and Answers on Motors and Generators

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?