Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Actuators Questions and Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Actuators Questions and Answers

Actuators Questions and Answers

Last updated: November 27, 2021 5:36 pm
Editorial Staff
Multiple Choice Questions
1 Comment
Share
4 Min Read
SHARE

Actuators Questions and Answers

1. A valve positioner :

a. Takes the place of a cascade control system
b. Provides more precise valve position
c. Makes a pneumatic controller in necessary
d. Provides a remote indication of valve position

Answer: b

2. Assume that a control valve regulates stream flow to a process and that high temperature makes the reaction hazardous. The usual pneumatically operated control valve utilizes the following action for fail-safe operation

a. Air to open
b. Air to close
c. 3 psi (20 kpa) to fully open
d. 15 psi (100 kpa) to fully close

Answer: a

3. The basic function of the spring in a control valve is to

a. Characterize flow
b. Oppose the diaphragm so as to position the valve according to signal pressure
c. Close the valve if air failure occurs
d. Open the valve if air failure occurs

Answer: b

4. A diaphragm actuator has a diaphragm area of 50 square inches and is adjusted to stroke a valve when a 3 to 15 psi (20 to 100 k Pa) Signal is applied. If the signal is 15 psi (100 k pa) the force on the valve stem will be :

a. 750 pounds
b. 750 pounds less than the opposing spring force
c. Dependent on hysteresis
d. None of the above

Answer:b

5. A high- pressure flow process requires a valve with tight packing. This would suggest that :

a. A valve positioner should be employed
b. The actuator must be sized to provide adequate force
c. Oversized pneumatic signals lines are required
d. The controller supplying the signal to the valve must have a very narrow proportional band.

Answer: b

6. An electronic controller creates a 4 to 20mA dc signal that must actuate a steam valve for temperature control. The best and most economical choice would be to :

a. Use an all-electric actuator system
b. Convert to a pneumatic signal at the controller and use a pneumatic actuator.
c. Use pneumatic actuator with an electric to pneumatic valve positioner
d. None of the above

Answer:c

7. A pressure control process using proportional plus integral control has a time constant of 10 seconds. The best choice of actuator would be :

a. An electric motor
b. A pneumatic diaphragm
c. A piston and cylinder
d. A solenoid electrical

Answer: b

8. A diaphragm actuator has a diaphragm area of 115 square inches. A valve positioner is attached to the actuator and fed with 22 psi air supply. If after 9 psi signal is received from the controller the signal changes to 10 psi and the valve fails to move. What is the force applied to the valve stem?

a. 2.530 pounds
b. 1.495 pounds
c. 1.035 pounds
d. None of the above

Answer: a

9. One advantage of an electric to pneumatic valve positioner is :

a. It can be used on flow control
b. It produces positive valve position
c. It conserves energy
d. It dampers valve travels

Answer: b

10. A single seated globe valve containing a plug 1 1/2 inches in diameter is used in a line pressurized to 500 psi. What actuator force is required for tight Shutoff.?

a. 884 pounds
b. 2,000 pounds
c. Depends upon direction of flow through the valved
d None of the above

Answer: c

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Infrared Gas Analyzers Questions & Answers
Measurement and Instrumentation Objective Questions – Part 3
Difference Equations
State Variables & Linear Discrete Time Systems
Parameter Optimization : Servomechanims
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • mehdi Eisvand says:
    August 13, 2020 at 8:48 am

    In your workplace, with which group is the actuator repair?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Stability in Frequency Domain

Tuning of PID Controllers

Ion Analyzers Questions and Answers

Ion Analyzer Questions & Answers

MCQ on Measurement and Instrumentation

MCQ on Measurement and Instrumentation

Industrial safety Objective Questions and Answers

Top 10 Industrial safety Objective Questions

Pollution Monitoring Instruments Questions and Answers

Carbon Monoxide Questions & Answers

Mass Spectrometer Questions and Answers

Gas Chromatograph- Mass Spectrometer

Analyzers Questions and Answers

Magnetic Wind Instruments Questions & Answers

State Variable Analysis and Design

Controllability & Observability

More Articles

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 11

Transistors Questions & Answers

Transistors Questions & Answers

Pressure Drop Calculator

Pressure Drop Calculator

Equal Flow Balance Operation of Parallel Compressors

Types of Surge Control for Parallel Gas Compressors

D flip flop in PLC

D Flip Flop PLC Ladder Logic

4-20 mA Conversion Formulas

Standard 4 to 20 mA Conversion Formula

What is Transformer Bushing

What is Transformer Bushing? Working Principle

Magnetic Level Gauge Float

Magnetic Level Gauge Float Design

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?