Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: X-Ray Fluorescence Spectrometry Questions and Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > X-Ray Fluorescence Spectrometry Questions and Answers

X-Ray Fluorescence Spectrometry Questions and Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

X-Ray Fluorescence Spectrometry Questions and Answers

1. If the absorption of electromagnetic radiation by matter results in the emission of radiation of same or longer wavelengths for a long or a short time, the phenomenon is termed as which of the following?

a) Luminescence
b) Fluorescence
c) Phosphorescence
d) Spontaneous emission

Answer: a

Explanation: If the absorption of electromagnetic radiation by matter results in the emission of radiation of same or longer wavelengths for a short or a long time, the phenomenon is termed as luminescence. Usually, absorption of electromagnetic radiation results in emission of radiation.

2. If the absorption of electromagnetic radiation by matter results in the emission of radiation of same or longer wavelengths for a short time, the phenomenon is termed as which of the following?

a) Luminescence
b) Fluorescence
c) Phosphorescence
d) Spontaneous emission

Answer: b

Explanation: If the absorption of electromagnetic radiation by matter results in the emission of radiation of same or longer wavelengths for a short time, the phenomenon is termed as fluorescence. Fluorescence emissions are characteristic of the particular element.

3. If the absorption of electromagnetic radiation by matter results in the emission of radiation of same or longer wavelengths for a long time, the phenomenon is termed as which of the following?

a) Luminescence
b) Fluorescence
c) Phosphorescence
d) Spontaneous emission

Answer: c

Explanation: If the absorption of electromagnetic radiation by matter results in the emission of radiation of same or longer wavelengths for a long time, the phenomenon is termed as phosphorescence. Phosphorescence is a type of luminescence.

4. Prompt emission of X-ray by an atom ionised by a higher energy X-ray is a type of which of the following phenomena?

a) Luminescence
b) Fluorescence
c) Phosphorescence
d) Spontaneous emission

Answer: b

Explanation: Prompt emission of X-ray by an atom ionised by a higher energy X-ray is a type of fluorescence. Fluorescence emissions are characteristic of the particular element.

5. The measurement of intensity of fluorescent X-rays provide a simple and ____________ way of _____________ analysis. Fill in the blanks.

a) Destructive, quantitative
b) Non-destructive, quantitative
c) Destructive, qualitative
d) Non-destructive, qualitative

Answer: b

Explanation: The measurement of intensity of fluorescent X-rays provide a simple and non-destructive way of quantitative analysis.

6. The energy of the emitted X-rays depends upon the _________ of the atom and their intensity depends upon the __________

a) Atomic number, amount of sample
b) Mass number, amount of sample
c) Mass number, concentration of atoms
d) Atomic number, concentration of atoms

Answer: d

Explanation: The energy of the emitted X-rays depends upon the atomic number of the atom and their intensity depends upon the concentration of atoms in the sample. X-ray fluorescence spectroscopy is based on this principle.

7. Which of the following is Mosely’s equation if ‘C’ is the speed of light, ‘a’ is proportionality constant, ‘σ’ is a constant which depends on electronic transition series, ‘Z’ is the atomic number and ‘λ’ is the wavelength?

a) Cλ= a(Z-σ)2
b) C/λ= a(Z-σ)2
c) C(Z-σ)2= aλ
d) C(Z-σ)2= a/λ

Answer: b

Explanation: The Mosely’s equation is, C/λ= a(Z-σ)2.
It gives the relationship between speed of light, reciprocal of wavelength and atomic number.

8. The problem of spectral interference is not severe in X-ray spectroscopy.

a) True
b) False

Answer: a

Explanation: The problem of spectral interference is not severe in X-ray spectroscopy. This is due to the relative simplicity of the X-ray spectra.

9. In X-ray fluorescence spectrometer, the relationship between the excitation intensity and the intensity of fluorescence does not depend on which of the following?

a) Spectrum of the incident radiation
b) Angle of radiance
c) Molecular weight
d) Incident angle

Answer: d

Explanation: In X-ray fluorescence spectrometer, the relationship between the excitation intensity and the intensity of fluorescence does not depend on the incident angle. It depends on absorption of path length.

10. Fluorescent X-ray spectrometers would require only moderate-intensity X-ray tubes.

a) True
b) False

Answer: b

Explanation: Fluorescent X-ray spectrometers would require high-intensity X-ray tubes. They also require sensitive detectors and suitable X-ray optics.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Robotic Control System – Part II
Electrical Measurements and Instrumentation Objective Questions & Answers
X-Ray Spectroscopy Questions & Answers
The Z-Transform
Closed-Loop Frequency Response
UV Visible Spectrometers Questions and Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Process Pressure Measurement Objective Questions
Special Designs of Ion Selective Electrodes Questions & Answers
Controller Components – Part 1 Objective Questions
Instrumentation for Electron Spectroscopy
Steady-state Errors & Error Constants
Inductively Coupled Plasma Mass Spectrometer
Stability Analysis by Describing Functions
Atomic Absorption Spectroscopy Questions & Answers
Digital Circuits Questions & Answers
X-Ray Diffractometers Questions & Answers

Keep Learning

Stability in Frequency Domain

The Design Problem

Mathematical Models of Physical Systems

Block diagram Algebra Objective Questions

State Variable Analysis and Design

State Models for Linear Continuous Time Systems

Feedback Characteristics of Control Systems

Linearizing Effect & Regenerative Feedback MCQ

Mass Spectrometer Questions and Answers

Radiofrequency Mass Spectrometer

Chromatography Questions & Answers

Detection System of Liquid Chromatography Questions & Answers

Industrial safety Objective Questions and Answers

Top 10 Industrial safety Objective Questions

Flame Emission Photometers Questions & Answers

Flame Emission Photometers Questions & Answers

Discover More

Cars Garage Counter From the Same Door PLC Logic

Cars Garage Counter From the Same Door PLC Logic

Types of Instructions in PLC Programming

Types of Instructions in PLC Programming

Python in Industrial Automation

Python in Industrial Automation and Control Systems

Triangle A-B-C- with Arc “A-C”

Instrument Tube Fitting Installation – Part 2

Differential Pressure Sensor Calibration

Differential Pressure Sensors Calibration Procedure

Most Common Types of Cyber Attacks

20 Most Common Types of Cyber Attacks

MOS Gas Sensor Principle

MOS Type Gas Sensor Principle

ungrounded-or-isolated-neutral-system-disadvantages

Ungrounded or Isolated Neutral System Disadvantages

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?