Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Magnetic Wind Instruments Questions & Answers

Magnetic Wind Instruments Questions & Answers

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Magnetic Wind Instruments Questions & Answers

1. Which of the following does not occur in Hartman and Braun oxygen analyzer based on magnetic wind?

a) Oxygen is attracted to magnetic field
b) Oxygen becomes less paramagnetic due to rise in temperature
c) Resistance change in a resistance connected to the Wheatstone bridge occur
d) Wheatstone Bridge becomes balanced due to temperature change

Answer: d

Explanation: In Hartman and Braun oxygen analyzer, the magnetic wind cools the heated winding. As a result, the bridge becomes unbalanced.

2. Which of the following is not a cause of error that could occur in Hartman and Braun oxygen analyzer based on magnetic wind?

a) The filament temperature could be affected by changes in thermal conductivity of the carrier gas
b) Hydrocarbons in sample stream may react on the heated filaments
c) Gravitation chimney flow effect lead to errors when cross tube is horizontal
d) Combustible gases may react on the heated filaments

Answer: c

Explanation: Error occurs when cross tube is vertical. When cross tube is horizontal, errors due to gravitation chimney flow effect is avoided.

3. Hydrocarbons need to be removed from the sample gas to avoid errors in Hartman and Braun oxygen analyzer.

a) True
b) False

Answer: a

Explanation: Hydrocarbons need to be removed from the sample gas to avoid errors. This is because they may react on the heated filaments and lead to change in temperature and resistance.

4. Magnetic wind analyzers are also known as which of the following?

a) Thermo-magnetic analyzers
b) Electro-magnetic analyzers
c) Thermo-analytical analyzers
d) Hot wire analyzers

Answer: a

Explanation: Magnetic wind analyzers are also known as Thermo-magnetic analyzers. In Europe, it is known as Magnetic wind analyzers. In United States, it is known as Thermo-magnetic analyzers.

5. In OXYMAT-M oxygen analyser which of the following is usually used as reference gas?

a) Hydrogen
b) Nitrogen
c) Helium
d) Ambient air

Answer: d

Explanation: In OXYMAT-M oxygen analyser, ambient air is usually used as reference gas. Its measuring procedure is based on pressure difference which develops between two gases having different oxygen concentration in the magnetic field.

6. Which of the following is used in magnetic wind instruments to determine the amount of oxygen?

a) Change in resistance
b) Change in capacitance
c) Change in inductance
d) Change in concentration

Answer: a

Explanation: In magnetic wind instruments to determine the amount of oxygen, change in temperature leads to a change in resistance. This change in resistance is measured to determine the amount of oxygen.

7. Which of the following concepts are not used in magnetic wind instruments?

a) Change in resistance due to cooling by magnetic wind
b) Displacement of membrane by magnetised oxygen
c) Difference in pressure difference between two gases having varying concentration of oxygen
d) By measuring temperature using thermometer

Answer: d

Explanation: Temperature is not measured in magnetic wind instruments. The cooling effect of magnetic wind causes a change in resistance which is measured.

8. How are the hydrocarbons in the samples removed in magnetic wind instruments?

a) By using a cold trap
b) By using a filter
c) By using a semipermeable membrane
d) By using magnetic effect

Answer: a

Explanation: The hydrocarbons in the samples are removed in magnetic wind instruments by using a cold trap. It is removed to avoid combustion.

9. Which of the following bridges are used in magnetic wind instruments?

a) Wheatstone bridge
b) Kelvin’s bridge
c) Anderson’s bridge
d) Schering’s bridge

Answer: a

Explanation: Wheatstone bridge is generally used in magnetic wind instruments. The change in resistance due to cooling effect is measured using Wheatstone bridge.

10. The extremely high inertia of the thin membrane in the oxygen sensor allows it to rapidly attain equilibrium.

a) True
b) False

Answer: b
Explanation: The extremely low inertia of the thin membrane in the oxygen sensor allows it to attain equilibrium. It reaches equilibrium state in 0.25 to 0.5 seconds.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Absorption Instrumentation Questions & Answers
Effect of Adding a Zero to a System – II
Pressure Measurement Multiple Choice Questions
Fluorescent Spectrometer Questions & Answers
Root Locus Concepts Objective Questions
Process Pressure Measurement Objective Questions
Share This Article
Facebook Copy Link Print
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Magnetic Deflection Mass Spectrometer Questions & Answers
Nuclear Magnetic Resonance Spectrometer Questions & Answers
Neural Networks
The Z-Transfer Function
Liapunov’s Stability Criterion – Part I
Stepper Motors Objective Questions & Answers
Radiation Detectors Questions & Answers
Controller Components – Part 2 Objective Questions
Steady-state Errors & Error Constants
Controllability & Observability

Keep Learning

Liapunov’s Stability Analysis

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

Frequency Response MCQ

Bode Plots MCQ

Programmable Logic Controllers Multiple Choice Questions

Programmable Logic Controllers Multiple Choice Questions

Pneumatic Control Mechanisms Objective Questions

Pneumatic Control Mechanisms Objective Questions

Liapunov’s Stability Analysis

Liapunov’s Stability Criterion – Part II

Stability in Frequency Domain

Time Domain Analysis

Transmission and Distribution Interview Questions

Measurement and Instrumentation Objective Questions – Part 3

Nonlinear Control Systems

Stability of Nonlinear System – II

Discover More

How to Detect Speed of Conveyor in PLC

How to Detect Speed of Conveyor in PLC?

Guided-wave Radar Level Measurement Animation

De-energized Electrical Circuits

De-energized Electrical Circuits, Networks, and Equipment

Difference Between NEMA and IEC Motors

Difference Between NEMA and IEC Motors?

OPC classic introduction

Overview of OPC Communication

WirelessHART mesh network

WirelessHART

Pressure Switch Construction

Basics of Pressure switches

Components of SCADA

Components of SCADA

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?