Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Amino-Acid Analyzers Questions & Answers

Amino-Acid Analyzers Questions & Answers

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Amino-Acid Analyzers Questions & Answers

1. What is the drawback that occurs in using ion exchange chromatography on sulphonated polystyrene resin and colourimetry for amino-acid analysis?

a) Less accuracy
b) Low resolution
c) Inconvenient to handle many individual samples
d) Slow in operation

Answer: c

Explanation: When ion exchange chromatography is used for amino-acid analysis, high accuracy is obtained. It is inconvenient to handle many individual samples and cleaning of glassware is laborious.

2. Which one of the following methods is the most suitable for amino-acid analysis?

a) Gas chromatography
b) Ion exchange chromatography
c) Paper electrophoresis
d) Resin column chromatography

Answer: d

Explanation: Resin column chromatography is the most suitable for amino-acid analysis. Here, ion exchange resin chromatography is followed.

3. Which of the following colour reagents are used in Resin column chromatography?

a) Marquis reagent
b) Benedict reagent
c) Ninhydrin
d) Nessler’s reagent

Answer: d

Explanation: Ninhydrin is the colour reagent used in resin column chromatography. The colour reaction occurs during a known period and controlled temperature.

4. Which of the following amino-acids is measured at a wavelength of 440nm using photometric systems?

a) Proline
b) Alanine
c) Glutamine
d) Valine

Answer: a

Explanation: Proline and hydroxyproline are measured at 440nm. All the other amino-acids are measured at 570nm.

5. In Automatic amino-acid analyzer, the sample containing ___________ of each amino compound is introduced at the top of the ion exchange column.

a) 1 to 10 µmoles
b) 1 to 10 moles
c) 0.05 to 2 moles
d) 0.05 to 2 µmoles

Answer: d

Explanation: In Automatic amino-acid analyzer, the sample having 0.05 to 2 µmoles of each amino compound is introduced at the top of the ion exchange column. Buffer is then supplied to the column.

6. Which of the following cannot be analysed using resin column chromatography?

a) Peptides
b) Amines
c) Amino compounds
d) Components which are ninhydrin negative

Answer: d

Explanation: Components which are ninhydrin negative cannot be analysed using resin column chromatography. Only the components that are nindydrin positive are analysed using this method.

7. Trapped air in pumps of Automatic amino-acid analyzer is eliminated using which of the following ways?

a) Suction pump
b) De-aerator
c) Overcome naturally by pump pressure
d) Using pulse damper

Answer: b

Explanation: De-aerator is used to eliminate trapper air in pumps of automatic amino-acid analyzer. Here, bubble-trap type de-aerator is used.

8. Amino-acids are distinguishable from each other only by one or two atoms in their structure.

a) True
b) False

Answer: a

Explanation: Amino-acids are distinguishable from each other only by one or two atoms in their structure. They are components all proteins and are essential for growth of organisms.

9. What is the drawback that occurs in using gas chromatography for amino-acid analysis?

a) Costly
b) Cannot be used for proteins or polypeptides
c) Slow process
d) Complex in operation

Answer: b

Explanation: Gas chromatography cannot be used for proteins or polypeptides. Further, accuracy is lost while converting amino-acids into gaseous phase.

10. Resin column chromatography does not involve breaking of bonds in amino-acids.

a) True
b) False

Answer: b

Explanation: Resin column chromatography involves breaking of bonds in amino-acids. This causes a delay as acid is eluted through the column by a buffer.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Top 1000 Analytical Instrumentation Questions & Answers
Combination Electrode Questions & Answers
Block diagram Algebra Objective Questions
Operation of Chromatography Questions & Answers
Frequency Response MCQ
NO2 Analyzer Questions & Answers
Share This Article
Facebook Copy Link Print
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Instrument Calibration Multiple Choice Questions
Cascade Compensation in Time Domain
Measurement and Instrumentation Objective Questions – Part 1
AC Circuits Multiple Choice Questions
Relative Stability Analysis
Basic ESR Spectrometer
Objective Questions of Building Fire and Gas Detectors
Time Domain Analysis
Transfer Functions Objective Questions
Nyquist Stability Criterion

Keep Learning

Stability in Frequency Domain

Cascade Compensation in Frequency Domain

Advances in Control System

Neural Networks

Spectrometers Questions and Answers

X-Ray Fluorescence Spectrometry Questions and Answers

State Variable Analysis and Design

Concepts of State, State Variables & State Model

Time Response Analysis

Time Response of Second Order Systems – I

PN Junction Questions & Answers

Measurement and Instrumentation Objective Questions – Part 5

Hydraulic Systems Objective Questions

Hydraulic Systems Objective Questions

Ion Analyzers Questions and Answers

Ion Selective Electrodes Questions and Answers

Discover More

Most Asked Questions on SCADA

Most Asked Questions on SCADA with Answers

Instrumentation Engineers Interview Questions & Answers

Instrumentation Engineers Interview Questions & Answers

Control Valves Pre-Commissioning Checklist

Control Valves Pre-Commissioning Checklist

Coil Type Timers in Siemens PLC Programming

Coil Type Timers in Siemens PLC Programming

Electrical Machines Questions and Answers

Motor Losses and Efficiency Quiz

Cooling Water Circulating Pump Low throughput

Cooling Water Circulating Pump Low throughput Resolved

Electrical Link Box

What is a Link Box?

How to Install Ultrasonic Level Transmitters 5

How to Install Ultrasonic Level Transmitters

Follow US