Multiple Choice Questions

Z-transform Analysis of Sampled-Data Control Systems

Z-transform Analysis of Sampled-Data Control Systems

1. The DFT of a signal x(n) of length N is X(k). When X(k) is given and x(n) is computed from it, the length of x(n)

a) Is increased to infinity
b) Remains N
c) Becomes 2N – 1
d) Becomes N2

Answer: a

Explanation: When X (k) is given and x (n) is computed from it, the length of x (n) is increased to infinity.

2. The system having input x (n) related to output y(n) as y (n) = log |x (n)| is:

a) Nonlinear, causal, stable
b) Linear, noncausal, stable
c) Nonlinear, causal, not stable
d) Linear, noncausal, not stable

Answer: a

Explanation: As y (n) is the function of x (n) hence it is nonlinear but it is bounded and also depends upon past and present values therefore it is stable and causal respectively.

3. Zero-order hold used in practical reconstruction of continuous-time signals is mathematically represented as a weighted-sum of rectangular pulses shifted by:

a) Any multiples of the sampling interval
b) Integer multiples of the sampling interval
c) One sampling interval
d) 1 second intervals

Answer: b

Explanation: Zero-order hold is used to reconstruct the continuous-time signal which is represented as a weighted sum of rectangular pulses shifted by integer multiples of the sampling interval.

4. When two honest coins are simultaneously tossed, the probability of two heads on any given trial is:

a) 1
b) 3/4
c) 1/2
d) ¼

Answer: d

Explanation: Total outcomes =4
Favorable outcomes =1
Hence probability =1/4.

5. A continuous-time periodic signal x(t), having a period T, is convolved with itself. The resulting signal is

a) Not periodic
b) Periodic having a period T
c) Periodic having a period 2T
d) Periodic having a period T/2

Answer: b

Explanation: Periodic having a period T Convolution of a periodic signal (period T) with itself will give the same period T.

6. If the Fourier series coefficients of a signal are periodic then the signal must be

a) Continuous-time, periodic
b) Discrete-time, periodic
c) Continuous-time, non-periodic
d) Discrete-time, non-periodic

Answer: b

Explanation: Discrete-time, periodic these are the properties of the discrete-time periodic signal.

7. The region of convergence of a causal finite duration discrete-time signal is

a) The entire z-plane except z = 0
b) The entire z-plane except z = ∞
c) The entire z-plane
d) A strip in z-plane enclosing jω–axis

Answer: a

Explanation: For discrete time signal for any causal system the region of convergence is always entire z-plane but except z =0.

8. The probability cumulative distribution function must be monotone and

a) Increasing
b) Decreasing
c) Non-increasing
d) Non-decreasing

Answer: d

Explanation: The cumulative distribution function that is monotone and non-decreasing or can be increasing.

9. Convolution is used to find:

a) The impulse response of an LTI System
b) Frequency response of a System
c) The time response of a LTI system
d) The phase response of a LTI system

Answer: c

Explanation: Convolution is the combination of addition and multiplication of the signals and used to find the impulse response of the LTI system.

10. The Fourier Transform of a rectangular pulse is

a) Another rectangular pulse
b) Triangular pulse
c) Sinc function
d) Impulse

Answer: c

Explanation: The Fourier Transform of a rectangular pulse that is the sinc function.

You've successfully subscribed !
Share

Recent Articles

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch
  • PLC Tutorials

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch

PLC ladder logic design to control 3 motors with toggle switch and explain the program…

3 weeks ago
  • PLC Tutorials

VFD Simulator Download – Free Yaskawa V1000 Software

VFD simulator download: Master the online tool from the Yaskawa V1000 & programming software for…

3 days ago
  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

6 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

6 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

7 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

4 days ago