How to do Continuity Testing using Multimeter

Continuity Testing using MultimeterContinuity Testing using Multimeter

  1. Turn the dial to Continuity Test mode ( ). It will likely share a spot on the dial with one or more functions, usually resistance (Ω). With the test probes separated, the multimeter’s display may show OL and Ω.
  2. If required, press the continuity button.
  3. First insert the black test lead into the COM jack.
  4. Then insert the red lead into the V Ω jack. When finished, remove the leads in reverse order: red first, then black.
  5. With the circuit de-energized, connect the test leads across the component being tested. The position of the test leads is arbitrary. Note that the component may need to be isolated from other components in the circuit.
  6. The digital multimeter (DMM) beeps if a complete path (continuity) is detected. If the circuit is open (the switch is in the OFF position), the DMM will not beep.
  7. When finished, turn the multimeter OFF to preserve battery life.

Continuity testing overview

  • Continuity is the presence of a complete path for current flow. A circuit is complete when its switch is closed.
  • A digital multimeter’s Continuity Test mode can be used to test switches, fuses, electrical connections, conductors and other components. A good fuse, for example, should have continuity.
  • A DMM emits an audible response (a beep) when it detects a complete path.
  • The beep, an audible indicator, permits technicians to focus on testing procedures without looking at the multimeter display.
  • When testing for continuity, a multimeter beeps based on the resistance of the component being tested. That resistance is determined by the range setting of the multimeter. Examples:
    • If the range is set to 400.0 Ω, a multimeter typically beeps if the component has a resistance of 40 Ω or less.
    • If the range is set 4.000 kΩ, a multimeter typically beeps if the component has a resistance of 200 Ω or less.
  • The lowest range setting should be used when testing circuit components that should have low-resistance value such as electrical connections or switch contacts.

Source : Fluke

Also Read: Measure Frequency using Multimeter

You've successfully subscribed !
Share

Recent Articles

  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

2 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

2 weeks ago
  • PLC Tutorials

Batch Mixing with PLC Ladder Logic Program

In this example, we will learn batch mixing with PLC ladder logic program using timer…

2 weeks ago
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

2 weeks ago
  • PLC Tutorials

PLC Programming Example with Pushbutton and Motor

In this article, you will learn the PLC programming example with pushbutton and motor control…

3 weeks ago
  • PLC Tutorials

Boolean Logic to PLC Programming

This article teaches how to convert Boolean logic to PLC programming ladder logic with the…

1 month ago