Turbo-Compressor Problem – Root Cause Analysis
Turbo-compressor turning gear chamber excessive oil belch posed indefinite plant shutdown problem.
Compressor Cracked Shaft Spacers
Process Air Compressor cracked shaft spacers; the plant Root Cause Analyzed, made the spacers and heat treated to lesser hardness and fitted on the spare and running rotor.
8000 RPM 8000 kW Turbine Problem
Root Cause Analysis (RCA): 8000 RPM, 8000 kW, Turbine Problem Threatened Yearlong Total Fertilizer Complex Outage.
Compressor Anti-Surge Control near-miss incident
The author root cause analyzed the near miss incident of compressor anti-surge control to resume production and surge prevention.
Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations
Root Cause Analysis (RCA): Compressor near ½-RPM frequency high magnitude shaft vibrations.
Malfunctioning Inlet Check Valves caused chaos at Compressor stop/trip
Root Cause Analysis (RCA): Malfunctioning inlet check valves caused 5-year long chaos at each stop/trip of the compressor.
Refrigeration Compressor Turbine Not-tripping when needed Trip
[RCA] Refrigeration Compressor Turbine Not-tripping when needed Trip Throttle Valve threatened potential compressor wrecks eliminated.
Process Air Compressor too Frequent & too Lengthy Overhauls Eliminated
Root Cause Analysis: K-602 Process Air Compressor too frequent & too lengthy overhauls Eliminated. RCA problem and solution provided.
Compressor IP Case Discharge Temperature Gradually Increases
Steam Turbine Driven centrifugal compressors K-601's IP case discharge temperatures gradually increases & lead to plant shutdown.
Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors
Root Cause Analysis (RCA): Persisting K-601 steam turbine driven centrifugal compressors Discharge Head 3‑monthly leaks.