Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: 4-20mA Linear Conversion Calculation for VFD Drive (Formula)
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > 4-20mA Linear Conversion Calculation for VFD Drive (Formula)

4-20mA Linear Conversion Calculation for VFD Drive (Formula)

4-20mA linear conversation calculation for VFD Drive and conversion Formula and with Example table. Download the Excel file.

Last updated: June 3, 2024 12:30 pm
Editorial Staff
Electrical Basics Formulas
No Comments
Share
4 Min Read
SHARE

4-20mA Linear Conversation Calculation for VFD Drive and conversion Formula and with Example table.

4-20mA VFD Drive Formula

Speed % = [(X-4)/16]*100

X = Current Value in mA

The below table shows the different valves for the respective 4-20 mA current and motor speed.

SLHzCurrent mAspeed % =Hz*2RPM        (0-1000)Speed At 90% =(Full speed-10%)Full RPM        (0-1500)Speed At 90% =(Full speed-10%)
004000.0%00
114.3222018300270
224.644036600540
334.9666054900810
445.288807212001080
555.2101009015001350
665.921212010818001620
776.241414012621001890
885.81616014424002160
996.881818016227002430
10107.22020018030002700
11116.42222019833002970
12127.842424021636003240
1312.582525022537503375
14136.82626023439003510
15148.482828025242003780
16158.83030027045004050
17169.123232028848004320
18177.63434030651004590
19189.763636032454004860
201910.083838034257005130
21208.24040036060005400
222110.724242037863005670
232211.044444039666005940
24238.84646041469006210
252411.684848043272006480
2625125050045075006750
27269.45252046878007020
282712.645454048681007290
292812.965656050484007560
3029105858052287007830
313013.66060054090008100
323113.926262055893008370
333214.246464057696008640
343310.86666059499008910
353414.8868680612102009180
363515.270700630105009450
373611.472720648108009720
383715.8474740666111009990
3937.516757506751125010125
403811.8767606841140010260
413916.48787807021170010530
424016.8808007201200010800
434112.4828207381230011070
444217.44848407561260011340
454317.76868607741290011610
464413888807921320011880
474518.4909008101350012150
484618.72929208281380012420
494719.04949408461410012690
504813.8969608641440012960
514919.68989808821470013230
52502010010009001500013500

Download the Excel File – Click Here

Author:

K Ramu

Manager Instrumentation

JP Mukherji & Associates Pvt ltd, Pune

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Understanding Braking Theory in VFD
Closed Tank Remote Seal Capillary type DP Transmitter
4-20mA Transmitters Calculations
Acceptable Earth Resistance Values
Automatic Motor Forward and Reverse Control using Timer
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Routine Tests of Circuit Breakers

Circuit Breaker Testing – Routine Tests of Circuit Breakers

Preventive Maintenance of Variable Frequency Drive

Preventive Maintenance of Variable Frequency Drive (VFD)

Phase Failure Relay

Why is Phase Failure Relay Required in LV Panels?

Earth Fault

What are Ground Fault and Earth Fault?

corroded tank

Cathodic Protection – Sacrificial Anodic and Impressed Current

Instrumentation Basics - Range Conversion Formula and Examples

Instrumentation Basics – Range Conversion Formula and Examples

How to Test a Motor using Megger

How to Test a Motor using Megger?

Difference Between HV and LV Cables

Difference Between HV and LV Cables

More Articles

Marking Machine

PLC SCL Program for Marking Machine

PID Tuning recommendations

PID Tuning Recommendations based on Process Dynamics

Vibration Analysis

Top 100 Vibration Analysis Questions and Answers

Independent-Voltage-Source-circuit-ideal-battery

Circuit Elements and Types of Circuits

PLC Star-Delta starter with interlock

Schneider PLC Example Program for Star-Delta System

Dip Tape Level Measurement

Manual Level Measurement

Bias in Proportional Controller

Why Bias used in Proportional Controller ?

Types of Cables

Types of Cables, Purpose, Advantages, Disadvantages, Applications

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?