Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Pneumatic Relay Questions
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Pneumatic Relay Questions

Pneumatic Relay Questions

Question - What is the response of this pneumatic relay to increasing pressure on each of its input ports?

Last updated: August 13, 2020 4:41 pm
Editorial Staff
Practical Questions
No Comments
Share
2 Min Read
SHARE

Question 1:

What is the response of this pneumatic relay to increasing pressure on each of its inputs? Does the output pressure increase as input A’s pressure increases? What happens when input B’s pressure increases?

Contents
Question 1:Answer:Question 2:Question 3:Read Next:

Note that both the sensing and sealing diaphragms are welded to the pilot rod, forming leak-proof and frictionless seals between chambers:

Pneumatic Relay

Can you think of an electronic circuit or device that acts in an analogous manner?

Answer:

A bit of explanation might be in order for the two diaphragms. The larger diaphragm is called the sensing diaphragm, while the smaller diaphragm is called the sealing diaphragm.

The purpose of the sealing diaphragm is to prevent air pressure at input B from leaking out into the vented chamber just to the left of the wedge-shaped pilot plug.

This sealing diaphragm is made small enough that its contribution to force on the stem is negligible. Only the sensing diaphragm is large enough to have any consequence upon the pilot valve’s action.

This is an equivalent electronic circuit:

Equivalent electronic circuit of Pneumatic Relay

Question 2:

Also, explain why the following relay design is better, using two sealing diaphragms instead of just one. A hint is to consider the common-mode rejection capacity of each relay design.

Once again, each of the metal diaphragms is welded to the rod to form leak-proof and frictionless seals:

Pneumatic Relay using two Diaphragms

 

Question 3:

Does the output pressure of this relay increase with increasing input pressure, or decrease with increasing input pressure?

In other words, is it a direct-acting or reverse acting type of relay?

 

Pneumatic Relay Operation

Share your answers with us through below comments section.

Read Next:

  • Relays in Ladder Logic
  • Diaphragm Pressure Sensor
  • Solid State Relays
  • What is a Interposing Relay?
  • Analyze the Relay Circuit

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Differential Pressure Measurement across Baghouse
Differential Pressure Transmitter with 5 Way Manifold Valve
Practical Process Control System Questions & Answers – 2
Air Compressor Control Circuit Problem
Draw the Symbols for Liquid Level Measuring Instruments
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Steam flow to the heat exchanger

Analytical Control System of Heat Exchanger Questions

AB PLC Temperature Switch

Programmable Logic Controller (PLC) Questions and Answers – 17

Calculate Incident Power in Radar Level Measurement

Calculate Incident Power in Radar Level Measurement

Steam flow to the heat exchanger

Analytical Process Control Question

PLC Program for Valves

PLC Pump Permissive Interlocks

two chemical streams are mixed together

Practical Process Control System Questions & Answers – 8

Two solenoid valves circuit

Solenoid Valves Questions & Answers – 4

Problem with Pirani Gauge

Problem with Pirani Gauge

More Articles

Top 100 Power Electronics Questions & Answers

Top 100 Power Electronics Questions & Answers

flow Nozzle

Flow Nozzle Principle, Advantages, Disadvantages, Applications

Strip-Chart-Recorder-Working-Principle

Strip Chart Recorder Working Principle

Multiplexers and Demultiplexers Objective Questions

Multiplexers and Demultiplexers Objective Questions

Top 100 Instrumentation Engineering Questions & Answers

Top 100 Instrumentation Engineering Questions & Answers

PLC Program for Analog Input Sampling

PLC Analog Input Sampling Ladder Logic

Preventive Maintenance of Variable Frequency Drive

Preventive Maintenance of Variable Frequency Drive (VFD)

STAR DELTA Starter PLC Logic

STAR DELTA Programming using PLC Controller

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?