Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Calculate the appropriate millivoltage values of a Thermocouple
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Calculate the appropriate millivoltage values of a Thermocouple

Calculate the appropriate millivoltage values of a Thermocouple

Last updated: December 10, 2019 4:21 pm
Editorial Staff
Practical Questions
No Comments
Share
1 Min Read
SHARE

Calculate the appropriate millivoltage values and potentiometer resistances to simulate a thermocouple at the desired temperatures, assuming the ambient temperature at the transmitter is 72 oF and the transmitter has cold junction compensation enabled:

simulate a thermocouple

Calculate the following :

  • Tsimulate = 550 oF ; Vinput = _____ mV ; Rpot = _____ Ω
  • Tsimulate = 300 oF ; Vinput = _____ mV ; Rpot = _____ Ω
  • Tsimulate = 150 oF ; Vinput = _____ mV ; Rpot = _____ Ω

Answer :

  • Tsimulate = 550 oF ; Vinput = 14.516 mV ; Rpot = 741.39 Ω
  • Tsimulate = 300 oF ; Vinput = 6.815 mV ; Rpot = 347.80 Ω
  • Tsimulate = 150 oF ; Vinput = 2.278 mV ; Rpot = 116.20 Ω
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Resistance Temperature Detector (RTD) Questions – 2
Loop Powered Pressure Transmitter
Programmable Logic Controller (PLC) Questions and Answers – 8
How much Pressure will Remote Seal Pressure Transmitter Indicate?
Draw Limit Switch Symbol ?
Pressure Transmitter Re-Range Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Process Control High Level Alarm Fault Analysis
Practical Process Control System Questions & Answers – 1
Programmable Logic Controller (PLC) Questions and Answers – 1
Paint Mixing System
Heat Exchanger Differential Pressure Transmitter
Practical Process Control System Questions & Answers – 3
Hydrostatic Level Transmitter Questions
How Overload Heaters used to Automatically Shut the Motor OFF ?

Keep Learning

Accuracy of a Manometer

What Affect the Pressure Measurement Accuracy of a Manometer?

Differential Pressure Transmitter with 5 Way Manifold Valve

Differential Pressure Transmitter with 5 Way Manifold Valve

Span of Pressure Gauge

How to Decrease Span of Pressure Gauge?

pressure switch control two lamps wiring

Draw Wiring of a Pressure Switch to control two lamps

Determine Level of Liquid in the Vessel and its Specific Gravity

Determine Level of Liquid in the Vessel and its Specific Gravity

Two solenoid valves circuit

Solenoid Valves Questions & Answers – 4

Tank uses 3 Pressure Transmitters to Measure Level & Density

Tank uses 3 Pressure Transmitters to Measure Level & Density

two chemical streams are mixed together

Practical Process Control System Questions & Answers – 12

Learn More

Basic Principles of Solar Technology

Basic Principles of Solar Technology

Latest Control Valves Interview Questions

Control Valve Interview Questions and Answers

5 Most Common Mistakes When Specifying Valves

5 Most Common Mistakes When Specifying Valves

Siemens S7 300 CPU Status and LED Errors Explanation

Siemens S7 300 CPU Status and LED Errors Explanation

Coal Hopper

Coal Based Fuel Feeding System for Boiler

Capping Machines

Capping Machine – 5 Aspects of Control Systems and Automation

Strip-Chart-Recorder-Working-Principle

Strip Chart Recorder Working Principle

Air Pre-heater

What is an Air Pre-heater? – Types, Working, Advantages

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?