Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Hydrogen Sulfide Gas (H2S)
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Fire & Gas System > Hydrogen Sulfide Gas (H2S)

Hydrogen Sulfide Gas (H2S)

Last updated: February 22, 2018 5:01 am
Editorial Staff
Fire & Gas System
No Comments
Share
5 Min Read
SHARE

Hydrogen Sulfide (H2S) is a highly toxic gas, with a pungent “rotten eggs” odor at low concentrations but no visible color. At higher concentrations, the gas acts as a nerve agent to de-sensitize human smell, so that it seems odorless. Its paralytic effect on smell extends to more important bodily functions such as breathing, causing rapid loss of consciousness and asphyxiation.

A photograph of a safety chart (taken at a wastewater treatment facility) shows just how toxic hydrogen sulfide gas is:

Hydrogen sulfide gas

Note how concentrations in the parts per million range are hazardous, and how little H2S concentration is required to paralyze one’s sense of smell. Hydrogen sulfide also happens to be flammable, its LEL value in air being 4.3%. However, the toxic properties of the gas are generally the more pressing concern when released into the atmosphere. Another hazardous property of hydrogen sulfide is its density: 1.18 times that of air. This means H2S gas will tend to collect in low areas such as pits, electrical vaults, and empty underground storage vessels.

The principal source of hydrogen sulfide gas is anaerobic (oxygen-less) decomposition of organic matter. Sewage treatment facilities, pulp mills, and oil refineries generate H2S gas in significant quantity, and so employees at such facilities must be continually aware of the associated hazards.

One of the most popular analytical sensing technologies for H2S gas appropriate for portable monitoring includes an electro-chemical reaction cell similar in principle to the micro fuel cells used to detect oxygen concentrations. Hydrogen sulfide gas entering such a cell engages in a specific chemical reaction, creating a small electrical current proportional to the gas concentration. Like oxygen-sensing fuel cells, these chemical cells also have limited lives and must be routinely replaced.

Overview of Hydrogen Sulfide (H2S)

Hydrogen sulfide is a colorless, flammable, extremely hazardous gas with a “rotten egg” smell. It occurs naturally in crude petroleum and natural gas, and can be produced by the breakdown of organic matter and human/ animal wastes (e.g., sewage). It is heavier than air and can collect in low-lying and enclosed, poorly ventilated areas such as basements, manholes, sewer lines and underground telephone/electrical vaults.

Detection by Smell :
  • Can be smelled at low levels, but with continuous lowlevel exposure or at higher concentrations you lose your ability to smell the gas even though it is still present.
  • At high concentrations – your ability to smell the gas can be lost instantly.
  • DO NOT depend on your sense of smell for indicating the continuing presence of this gas or for warning of hazardous concentrations.
Health Effects :

Health effects vary with how long, and at what level, you are exposed. Asthmatics may be at greater risk.

  • Low concentrations – irritation of eyes, nose, throat, or respiratory system; effects can be delayed.
  • Moderate concentrations – more severe eye and respiratory effects, headache, dizziness, nausea, coughing, vomiting and difficulty breathing.
  • High concentrations – shock, convulsions, unable to breathe, coma, death; effects can be extremely rapid (within a few breaths).
Before Entering Areas with Possible Hydrogen Sulfide :
  • The air needs to be tested for the presence and concentration of hydrogen sulfide by a qualified person using test equipment. This individual also determines if fire/explosion precautions are necessary.
  • If gas is present, the space should be ventilated.
  • If the gas cannot be removed, use appropriate respiratory protection and any other necessary personal protective equipment (PPE), rescue and communication equipment. Atmospheres containing high concentrations (greater than 100 ppm) are considered immediately dangerous to life and health (IDLH) and a selfcontained breathing apparatus (SCBA) is required.

Also Read : Fire Detection and Alarm System

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Basics of Fire Fighting Hydrant Systems
Objective Questions of Building Fire and Gas Detectors
Basics of Fire Detection and Alarm System
Fire and Safety
Interview Questions on Smoke Detection System
Fire Water Sprinklers Working Principle
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Flame Detector Testing Procedure
What is Bump Testing ?
Basics of Fire Extinguisher
Portable Gas Detectors Calibration Procedure
Ultrasonic Gas Leak Detectors (UGLD)
Fire and Gas System Interview Questions & Answers
Gas Detection Excel Converters
Industrial Flame Detectors
Deluge Valve Operation
Basics of Gas Monitoring

Keep Learning

Point Gas Detectors Principle

Point IR Detectors Vs Open Path IR Detectors

Smoke Detector Testing Procedure

Smoke Detector Testing Procedure

Fire Extinguishers Mock Test

Fire Extinguishers Mock Test

Rate Compensated Heat Detectors Working Principle

Rate Compensated Heat Detectors Working Principle

oxygen Safety Analyzer

Oxygen Safety Analyzer

Gas Detectors Practical Problems and Troubleshooting

Gas Detectors Practical Problems and Troubleshooting

foam fire protection system

Basics of Foam Fire Fighting System

Fire and Gas system Audible and Visual Alarms

Fire and Gas system Audible and Visual Alarms

Discover More

Current Earth Leakage Circuit Breaker

Types of Earth Leakage Circuit Breaker

Zener Diode Voltage Regulator Operation

Zener Diode Voltage Regulator Operation

Single-beam non-dispersive analyzer

Single-beam Non-dispersive Analyzer

Coriolis Mass Flow Meter Verification Procedure

Prover Tank Calibration and Mass Flow Meter Verification Procedure

Process Control Instrumentation Objective Questions

Process Control & Instrumentation Objective Questions – Set 2

OFF Delay Timer using PLC

OFF Delay Timer using PLC

Comparison of Flowmeters

Difference between Different Types of Flow Meters

Thyristor Interview Questions & Answers

Thyristor Interview Questions & Answers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?