Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Linearizing Effect & Regenerative Feedback MCQ
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Linearizing Effect & Regenerative Feedback MCQ

Linearizing Effect & Regenerative Feedback MCQ

Last updated: November 27, 2021 5:41 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Linearizing Effect & Regenerative Feedback

1. The effect of adding feedback makes the system__________

a) Linear
b) Non-linear
c) Time variant
d) Time invariant

Answer: a

Explanation: Consider the single loop system with forward path transfer function as the square function then the response generated is nonlinear if system is open loop but will be approximately linear if closed loop.

2. The relation between output response and input signal in closed loop system is :

a) Exponential
b) Parabolic
c) Linear
d) Nonlinear

Answer: c

Explanation: Due to the linearizing effect of the feedback the relation between output response and the input signal in closed loop system is linear.

3. Assertion (A): Practical systems must be closed loop system.
Reason (R): This is due to the fact that closed loop systems are least affected by parameter variations, stable, higher bandwidth, linear and more speed of response.

a) Both A and R are true and R is the correct explanation of A.
b) Both A and R are true but R is not the correct explanation of A.
c) A is true but R is false.
d) A is false but R is true.

Answer: a

Explanation: Practically systems used must be linear to avoid error, ease of calibration and also to get accurate results but the systems used are non-linear to avoid the error due to the linearity they are approximated.

4. Regenerative feedback is also called as_________________

a) Negative feedback
b) Positive feedback
c) No feedback
d) Negative and Positive Feedback

Answer: b

Explanation: As the name implies that is regenerates the oscillations hence by name it can be positive.

5. Which of the following are the characteristics of regenerative feedback:

a) Zero damping
b) Stable
c) Least sensitive to parameter variations
d) None of the mentioned

Answer: a

Explanation: Output response is slow and sluggish and transient time is more due to the oscillations.

6. Which of the following are true:

a) Sensitivity of regenerative feedback is more than negative feedback but less than non-feedback system
b) Sensitivity of regenerative feedback is more non-feedback system but less than negative feedback system
c) Sensitivity of regenerative feedback is less than both
d) Sensitivity of regenerative feedback is more than both

Answer: c

Explanation: Sensitivity of the positive feedback system is even more than non-feedback system and it is more by a factor of 1/1-GH.

7. Loop gain provided by the regenerative feedback makes the closed loop transfer function insensitive to G(s).

a) True
b) False

Answer: a

Explanation: As if the positive feedback loop gain is nearly considered to be unity then transfer function becomes insensitive to G(s).

8. Which of the following statements is correct for any closed loop system?

a) All the co-efficient can have zero value
b) All the co-efficient are always non-zero
c) Only one of the static error co-efficient has a finite non-zero value
d) None of the mentioned

Answer: c

Explanation: Closed loop systems are the systems with positive and negative feedback and for standard test signals error constants are defined and for one of the inputs one of the static error co-efficient has a finite non-zero value.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Control Systems Multiple Choice Questions
Process Pressure Measurement Objective Questions
Infrared Spectrometers Questions & Answers
Controller Components – Part 1 Objective Questions
The Design Problem
Chromatographic Behaviour of Solutes Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Control Loops Multiple Choice Questions

Control Loop Multiple Choice Questions

State Variable Analysis and Design

State Variables & Linear Discrete Time Systems

PN Junction Questions & Answers

Measurement and Instrumentation Objective Questions – Part 5

Analyzers Questions and Answers

Silica Analyzer Questions & Answers

Analyzers Questions and Answers

Analyzers Based on Gas Density Questions & Answers

PID Controllers Multiple Choice Questions

PID Controller Multiple Choice Questions

Mathematical Models of Physical Systems

Signal Flow Graphs Objective Questions

Top 100 Control Systems Objective Questions & Answers

Top 100 Control Systems Objective Questions & Answers

More Articles

Stilling well in liquid level measurement

Stilling Well in Interface Level Measurement System

fluid flow reversed through a Control Valve

What happens when Fluid Flow Reversed through Control Valve?

Digital Electronics Multiple Choice Questions

Memory Devices Objective Questions – Part 5

Cables Sheath Material

Instrument Cables Sheath Material

Pipeline Inspection Tools

Essential Industrial Pipeline Inspection Tools

What is Partial Stroke Test

What is Partial Stroke Test?

Electrical Machines Questions and Answers

DC Machines Torque Quiz

capacitor-filter-ripples

Ripple Voltage in Rectifiers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?