Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Gas Chromatograph- Mass Spectrometer
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Gas Chromatograph- Mass Spectrometer

Gas Chromatograph- Mass Spectrometer

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Gas Chromatograph- Mass Spectrometer

1. Which of the following is the most sensitive of the spectral methods?

a) Absorption spectroscopy
b) Mass spectroscopy
c) Flame emission spectroscopy
d) Atomic emission spectroscopy

Answer: b

Explanation: Mass spectroscopy is the most sensitive of the spectral methods. It permits direct introduction of a gas effluent’s stream.

2. Which of the following is the disadvantage of gas chromatography?

a) It is not a good method
b) It cannot be used for qualitative analysis
c) It cannot be used for separation of volatile components
d) It does not provide direct identification

Answer: d

Explanation: Gas chromatography is a very good method for separation of components of a mixture. It does not provide direct identification.

3. Cold tray is provided for liquid N2 or CO2 but is used only for extremely small samples.

a) True
b) False

Answer: a

Explanation: Cold tray is provided for liquid N2 or CO2. It is used only for mass spectral analysis of very small samples.

4. Which of the following is most often used in the chromatograph in gas chromatograph MS?

a) Curvette
b) Paper support
c) Capillary tube
d) Flask

Answer: c

Explanation: Capillary tube is most often used in the chromatograph in gas chromatograph MS. This is because low pressure has to be maintained.

5. GC- MS has been developed for which of the following systems?

a) Packed column
b) Open tubular column
c) Capillary column
d) Porous layer column

Answer: a

Explanation: GC- MS has been developed for packed column system. These allow for analyte molecules to be dynamically extracted from the carrier gas stream.

6. Which of the following problems occur when combining gas chromatography and mass spectroscopy?

a) Difference in operating pressures
b) Reduction in sensitivity
c) Direct identification is not possible
d) It does not permit direct introduction of the effluent

Answer: The problem that occurs when combining gas chromatography and mass spectroscopy is the difference in operating pressures. The pressure at the exit of the GC column is atmospheric.

7. The carrier gas with low molecular weight would diffuse at a higher rate than the higher molecular weight sample.

a) True
b) False

Answer: a

Explanation: The carrier gas with low molecular weight would diffuse at a higher rate than the higher molecular weight sample. The carrier gas would diffuse away from the line of flow.

8. Which of the following is the type of separator used in commercial GC-MS systems?

a) Jet type molecular separator
b) Porous tube
c) Teflon tube
d) Flow type separator

Answer: a

Explanation: Jet type molecular separator is the type of separator used in commercial GC-MS systems. Other methods are porous tube and Teflon tube.

9. The system for measurement of ion intensity in GS-MS system consists of which of the following?

a) Electrometer
b) Ion meter
c) Ion transducer
d) Intensity meter

Answer: a

Explanation: The system for measurement of ion intensity in GS-MS system consists of electrometer. It feeds a direct writing recorder.

10. The system for measurement of ion intensity in GS-MS system consists of which of the following?

a) Band pass amplifier
b) Narrow band amplifier
c) Wide band amplifier
d) Low pass amplifier

Answer: c

Explanation: The system for measurement of ion intensity in GS-MS system consists of a wide band amplifier. It feeds a direct writing recorder.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

The Z-Transfer Function
Closed-Loop Frequency Response
Permit to Work System Online Test
Optimal Control Problems – Part 1
Ionization of Gases Questions and Answers
Routh-Hurwitz Stability Criterion
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Experimentation of Transfer Function
Ion Spectroscopy Questions & Answers
Linearizing Effect & Regenerative Feedback MCQ
Construction of Phase -Trajectories
Level and Density Measurement Objective Questions
State Models for Linear Continuous Time Systems
Root Locus in Control Systems
Stepper Motors Objective Questions & Answers
Digital Control Systems Multiple Choice Questions
Transfer Functions Objective Questions

Keep Learning

Single Beam and Double Beam Instruments

Single Beam and Double Beam Instruments

Feedback Control Questions & Answers

Feedback Control Loop Questions & Answers

Time Response Analysis

Design Considerations for Higher Order Systems

Ion Spectrometers Questions & Answers

Ion Transducers Questions & Answers

Time Response Analysis

Steady-state Errors & Error Constants

Programmable Logic Controllers Multiple Choice Questions

Programmable Logic Controllers Multiple Choice Questions

Mass Spectrometer Questions and Answers

Time of Flight Mass Spectrometer

PN Junction Questions & Answers

Measurement and Instrumentation Objective Questions – Part 5

Discover More

Delete Siemens CPU Memory

How to Delete the Siemens CPU Memory?

Left-Hand Rule for Current-Carrying Conductors

DC Motor Theory

Turbine Meter in Gas Metering System

Read Gas Composition from Gas Metering System using RS485 Protocol

Compressor Did Not Trip

RCA – Compressor Did Not Trip on Suction Pressure Low Low

Differential Pressure Transmitter

Calculate Process Variable from 4-20mA using Fraction of Measurement

What is an Electrical Drive

What is an Electrical Drive? Types, Advantages, Disadvantages

3φ AC Power Connections

Three Phase Systems

phototransistor-circuit

Phototransistor Circuit Example

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?