Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Inductively Coupled Plasma Mass Spectrometer
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Inductively Coupled Plasma Mass Spectrometer

Inductively Coupled Plasma Mass Spectrometer

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Inductively Coupled Plasma Mass Spectrometer

1. ICP’s principle is similar to which of the following?

a) Flame emission spectroscopy
b) Fourier transforms spectroscopy
c) Atomic emission spectroscopy
d) Absorption spectroscopy

Answer: c

Explanation: ICP’s principle is similar to atomic emission spectroscopy. Samples are decomposed to neural elements in argon plasma in this method.

2. ICP is used to analyse samples in which of the following states?

a) Solids
b) Liquids
c) Gases
d) Solids and liquids

Answer: d

Explanation: ICP is used to analyse samples in both solid and liquid states. Atomic emission spectrometer is used to analyse only solid samples.

3. Solid samples are introduced into the ICP spectrometer using which of the following?

a) Nebulizer
b) Curvette having glass windows
c) Probe
d) Laser ablation system

Answer: d

Explanation: ICP spectrometer can be used for solid samples. They are introduced using laser ablation system.

4. Liquid samples are introduced into the ICP spectrometer using which of the following?

a) Nebulizer
b) Curvette having glass windows
c) Probe
d) Laser ablation system

Answer: a

Explanation: ICP spectrometer can be used for liquid samples. Aqueous samples are introduced using nebulizer.

5. Atomisation or ionisation occurs at which of the following conditions?

a) Vacuum pressure
b) Atmospheric pressure
c) Low pressure
d) High pressure

Answer: d

Explanation: Atomization or ionisation occurs at atmospheric pressure. The interface between the ICP and MS components are crucial in creating a vacuum.

6. Ions flow is pumped into the vacuum system using which of the following?

a) Orifice
b) Nozzle
c) Venturi meter
d) Dall tube

Answer: a

Explanation: Ions flow is pumped into the vacuum system using orifice. It expands in the vacuum system.

7. Which of the following is not the characteristic of ICP spectrometer?

a) Easy sample introduction
b) It can trace multiple elements
c) High detection limits
d) Accurate

Answer: c

Explanation: ICP spectrometer has low detection limits of mass spectrometer. It is capable of tracing multiple elements.

8. ICP spectrometer is a sequential multi-element analyser that has scan times less than ____ for one sweep.

a) 10ms
b) 20ms
c) 50ms
d) 100ms

Answer: b

Explanation: ICP spectrometer is a sequential multi-element analyser that has scan times less than 20ms for one sweep. Quadrupole mass analyser gives better unit mass resolution.

9. Double focussing section analysers offer better resolution than ICP spectrometry system.

a) True
b) False

Answer: a

Explanation: Double focussing section analysers offer better resolution than ICP spectrometry system. Their disadvantage is that they are large and have high capital cost.

10. The most common type of ion detector found in ICP system is which of the following?

a) Faraday cup collector
b) Channeltron
c) Micro-channel plate
d) Flame ionization detector

Answer: b

Explanation: The most common type of ion detector found in ICP system is channeltron electron multiplier. It is a cone or horn shaped tube.

11. Which of the following is the most accurate method of determination of elemental composition?

a) Spectroscopy
b) Isotope dilution
c) Isobar dilution
d) Chromatography

Answer: b

Explanation: The most accurate method of determination of elemental composition is isotope dilution. It permits calculation of concentration of an element.

12. Which of the following is the disadvantage of ICP mass spectroscopy?

a) Incapable of multi-element analysis
b) Less sensitivity
c) Impossible to obtain isotopic information
d) Not useful for detection of non-metals

Answer: d

Explanation: ICP mass spectroscopy has multi-element capability and high sensitivity. It is not capable of multi-element analysis.

13. The isobaric interference is not caused in which of the following elements?

a) Argon
b) Oxygen
c) Helium
d) Nitrogen

Answer: c

Explanation: The isobaric interference is not caused due to isotopes of helium. It is caused by isotopes of argon, oxygen and nitrogen.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Single Beam and Double Beam Instruments
Actuators Questions and Answers
Control Loop Multiple Choice Questions
Time of Flight Mass Spectrometer
Radiation Detectors Questions & Answers
Temperature Measurement Multiple Choice Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Hydraulic Systems Objective Questions
Electron Probe Microanalyser Questions & Answers
Control Systems Multiple Choice Questions
High Pressure Liquid Chromatography Questions & Answers
The inverse z-transform & Response of Linear Discrete Systems
Performance Indices
Measurement and Instrumentation Objective Questions – Part 4
Time Response of Second Order Systems – II

Keep Learning

Nuclear Magnetic Resonance Spectrometer Questions and Answers

Continuous Wave NMR Spectroscopy Questions & Answers

Ion Analyzers Questions and Answers

Special Designs of Ion Selective Electrodes Questions & Answers

Spectral Method of Analysis Questions & Answers

Spectral Method of Analysis Questions & Answers

Pneumatic Systems Objective Questions

Pneumatic Systems Objective Questions

Absorption Instrumentation Questions & Answers

Absorption Instrumentation Questions & Answers

Feedback Characteristics of Control Systems

Controller Components – Part 1 Objective Questions

Nonlinear Control Systems

Stability Analysis by Describing Functions

DC Circuits Multiple Choice Questions

DC Circuits Multiple Choice Questions

Learn More

SR Flip Flop Logic

How to implement SR Flip Flop using PLC Ladder Logic

Modbus Code

Modbus Relative Addressing

Coriolis mass flowmeter Density Measurement

How Coriolis Mass Flow Meter Measure Density?

Electrical Machines Questions and Answers

MCQ on Rotating Electrical Machines

Difference-between-pneumatic-electric-hydraulic-actuators

Difference between Pneumatic, Electrical & Hydraulic Actuators

Calculate Power in Parallel RC Circuit

Calculate Power in Parallel RC Circuit

Field Instruments Questions and Answers

Basics of Amplifiers Interview Questions

Temperature Measurement Interview

Temperature Measurement Interview Questions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?