Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Electrochemical Methods for Oxygen Analysis Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Electrochemical Methods for Oxygen Analysis Questions & Answers

Electrochemical Methods for Oxygen Analysis Questions & Answers

Last updated: November 27, 2021 5:36 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Electrochemical Methods for Oxygen Analysis Questions & Answers

1. Which of the following is not true about the galvanic method of oxygen analysis?

a) Electrodes are composed of noble and base metals
b) It can measure dissolved content of oxygen
c) Its principle is based on electrolysis
d) It utilizes an electronic cell

Answer: c

Explanation: Galvanic method of oxygen analysis is based on the reverse of electrolysis. In this method, the electrical current developed is related to the rate of oxygen uptake by the cell.

2. Which of the following is true about Hersch cell which is one of the arrangements of the galvanic cell?

a) Cell is spherical in shape
b) Cathode is made of porous material
c) Cathode is placed centrally
d) Cathode is formed by gauze which surrounds the anode

Answer: d

Explanation: In Hersch cell, the cell is cylindrical in shape. An anode is placed centrally and is made of porous material. The cathode is formed by gauze which surrounds the anode.

3. Polarographic cells type of electrochemical method uses which of the following concepts?

a) Cyclic reactions
b) Exothermic reactions
c) Reversible reactions
d) Redox reactions

Answer: d

Explanation: Polarographic cells type of electrochemical method uses redox reactions. It is used to measure the partial pressure of percentage of oxygen.

4. Which of the following methods, is the widely used method for trace gas analysis?

a) Galvanic methods
b) Conductometric method
c) Polarographic cells
d) Thermal conductivity method

Answer: b

Explanation: Conductometric method is the widely used method for trace gas analysis. This method is very convenient.

5. In the conductometric method, the difference in gas conductivity before and after passing sample gas denotes which of the following?

a) Efficiency of the cell
b) Quantity of reagent
c) Concentration of gas
d) Density of the reagent

Answer: c

Explanation: In the conductometric method, the difference in gas conductivity before and after passing sample gas denotes the concentration of gas. The sample gas is passed through the liquid reagent.

6. The conductometric method is not very suitable for measuring traces of which of the following gases in ppb range?

a) H2S
b) SO2
c) NH3
d) CO

Answer: d

Explanation: Conductometric method is not very suitable for measuring traces of CO. It is suitable for measuring traces of H2O.

7. Polarographic cells are not sensitive to which of the following gases?

a) Carbon monoxide
b) Carbon dioxide
c) Nitrous oxide
d) Oxygen

Answer: a

Explanation: Polarographic cells are not sensitive to carbon monoxide. They show 0.1% error while measuring oxygen.

8. In polarographic cell when potential is applied, oxygen is reduced at __________ when KCl is present.

a) Anode
b) Cathode
c) Electrolyte
d) Both the electrode

Answer: b

Explanation: In polarographic cell when potential is applied, oxygen is reduced at the cathode. Reduction reactions take place at the cathode. KCl is the electrolyte.

9. Polarographic cells are used to measure the partial pressure of gases only in static gas monitoring systems and not in continuous streams.

a) True
b) False

Answer: b

Explanation: Polarographic cells are not used to measure the partial pressure of gases in static gas monitoring systems alone. They can also be used for measuring the partial pressure of gases in continuous samples and injected samples.

10. Polarographic cells used for measuring the partial pressure of oxygen are temperature-sensitive.

a) True
b) False

Answer: a

Explanation: Polarographic cells used for measuring the partial pressure of oxygen are temperature-sensitive. This is because of diffusion coefficient changes with temperature.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Steady-state Errors & Error Constants
The inverse z-transform & Response of Linear Discrete Systems
Compensation Techniques : Control Systems
PLC Interview Questions and Answers
Construction of Root Loci
Absorption Instrumentation Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Relative Stability Analysis
Level and Density Measurement Objective Questions
Transfer Functions Objective Questions
Liquid Scintillation Counters Questions & Answers
Detection System of Liquid Chromatography Questions & Answers
Process Control Questions & Answers
Instrumentation for Electron Spectroscopy
Atomic Absorption Spectroscopy Questions & Answers
The Infinite Time Regulator Problem
Liquid Chromatography Questions & Answers

Keep Learning

Top 1000 Analytical Instrumentation Questions & Answers

Top 1000 Analytical Instrumentation Questions & Answers

Objective Questions of Building Fire and Gas Detectors

Objective Questions of Building Fire and Gas Detectors

Chromatography Questions & Answers

Detection System of Gas Chromatography Questions and Answers

Top 100 Control Systems Objective Questions & Answers

Top 100 Control Systems Objective Questions & Answers

Digital Control Systems

The Z-Transfer Function

Instrument Calibration Multiple Choice Questions

Instrument Calibration Multiple Choice Questions

PID Controllers Multiple Choice Questions

PID Controller Multiple Choice Questions

Ion Spectrometers Questions & Answers

Ion Spectroscopy Questions & Answers

Discover More

Phase Controlled Half Wave Rectifier RL Load

Power Electronics – Phase Controlled Half Wave Rectifier RL Load

Tunnel Diode

Tunnel Diode Working Principle

optical fiber cable junction box

Underwater Fibre Optic Cable

Instrumentation Transmitter

Instrumentation Common Measurement Issues

5-Port-2-Position-Valve-Animation

5 Port 2 Position Valve Working Principle

Control Valve Testing for Noise Measurement

Control Valve Testing for Noise Measurement

Omron PLC painting program

Product Painting PLC Program using Omron CX-Programmer

Ladder Logic for Stair-Case wiring using Toggle Switches

Ladder Logic for Stair-Case wiring using Toggle Switches

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?